{"product_id":"1788-cn2ff-allen-bradley-controlnet-series-linking-device","title":"1788-CN2FF Allen-Bradley ControlNet Series Linking Device","description":"\u003cp\u003eConfigured for ControlNet to Fieldbus protocol conversion in industrial communication networks, the \u003cstrong\u003eAllen-Bradley 1788-CN2FF\u003c\/strong\u003e (\u003cstrong\u003e1788-CN2FF\u003c\/strong\u003e Linking Device) provides direct communication interface conversion between control network infrastructure and field-level devices.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1788-CN2FF is a DIN-rail mounted linking device designed to connect ControlNet communication systems with Fieldbus networks. The unit operates with an 11-30 VDC supply range and provides physical interface conversion through 9-pin SUB-D connectors.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1788-CN2FF\u003c\/td\u003e\n\u003ctd\u003eBase catalog number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1788CN2FF\u003c\/td\u003e\n\u003ctd\u003eAlternate catalog format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1788-CN2FF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLinking Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eControlNet to Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e11-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e9-pin SUB-D connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.7 cm x 9.8 cm x 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e0.5 g at 10-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network Communication Interface\u003c\/h3\u003e\n\u003cp\u003eThe 1788-CN2FF supports communication architecture conversion between ControlNet and Fieldbus systems. The module manages protocol exchange between the ControlNet controller environment and connected field devices through dedicated communication channels.\u003c\/p\u003e\n\u003cp\u003eThe Allen-Bradley industrial control platform uses deterministic network structures for controller-to-I\/O communication. The linking device allows Fieldbus instruments and devices to exchange process information with ControlNet-based control systems without direct modification of the controller network architecture.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1788-CN2FF Linking Device\u003c\/li\u003e\n\u003cli\u003e1 x Integrated ControlNet communication interface\u003c\/li\u003e\n\u003cli\u003e1 x Fieldbus interface connection\u003c\/li\u003e\n\u003cli\u003e1 x DIN-rail mounting hardware assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the device on a compatible DIN rail inside the control enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient clearance around communication connectors for wiring access.\u003c\/li\u003e\n\u003cli\u003eVerify enclosure environmental conditions before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the 11-30 VDC supply according to the device power requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm supply polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring separately from high-voltage power conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eNetwork Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify ControlNet network parameters before commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck Fieldbus communication settings for connected field devices.\u003c\/li\u003e\n\u003cli\u003eConfirm connector pin assignments before connecting communication cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the primary function of the 1788-CN2FF?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module converts communication between ControlNet systems and Fieldbus networks, allowing data exchange between different industrial communication layers.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat mounting method does this device use?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1788-CN2FF uses a DIN-rail mounting design for installation inside industrial control cabinets.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat supply voltage range is supported?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe device accepts an operating supply range of 11-30 VDC according to the provided specifications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat connectors are provided on the module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe linking device uses 9-pin SUB-D connectors for communication interface connections.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat operating temperature range is specified?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module operates within a temperature range of 0 deg C to 60 deg C.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat environmental humidity condition is supported?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified operating humidity range is 5-95% relative humidity without condensation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan the module be installed near vibration sources?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe device specification includes vibration resistance of 0.5 g at 10-500 Hz for industrial installation environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes the module require special network configuration?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ControlNet and Fieldbus communication parameters must be configured according to the connected controller and field devices.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066453446829,"sku":"1788-CN2FF","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1788-CN2FF_1.jpg?v=1785852747","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1788-cn2ff-allen-bradley-controlnet-series-linking-device","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}