{"product_id":"1784-ktcx15-allen-bradley-controlnet-isa-eisa-bus-interface-card","title":"1784-KTCX15 Allen-Bradley ControlNet ISA\/EISA Bus Interface Card","description":"\u003cp\u003eConfigured for ControlNet communication through an ISA\/EISA host bus, the \u003cstrong\u003eAllen-Bradley 1784-KTCX15\/B\u003c\/strong\u003e (\u003cstrong\u003e1784-KTCX15\u003c\/strong\u003e ControlNet Interface Card) provides a host computer interface with dual BNC network connections and a specified 16 KB memory requirement.\u003c\/p\u003e\n\u003ch3\u003eCatalog and Hardware Identification\u003c\/h3\u003e\n\u003cp\u003eThe supplied references identify 1784-KTCX15 as a ControlNet communication interface card for ISA\/EISA bus systems. The alternate references are 1784KTCX15 and 1784-KTCX15\/B. No additional suffix decoding is assigned because the supplied data does not define the meaning of \"\/B\".\u003c\/p\u003e\n\u003ch3\u003eElectrical and Mechanical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1784-KTCX15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Model\u003c\/td\u003e\n\u003ctd\u003e1784KTCX15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Catalog Reference\u003c\/td\u003e\n\u003ctd\u003e1784-KTCX15\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControlNet ISA\/EISA Bus Interface Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Bus\u003c\/td\u003e\n\u003ctd\u003eISA\/EISA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connectors\u003c\/td\u003e\n\u003ctd\u003e2 x BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Requirement\u003c\/td\u003e\n\u003ctd\u003e16 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e57.6 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003e75 ohm resistors required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 x 2.5 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControlNet Host Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1784-KTCX15 provides a ControlNet communication interface between the network and an ISA\/EISA host computer bus. The card uses two BNC connectors for the specified ControlNet network connection.\u003c\/p\u003e\n\u003cp\u003eThe supplied data specifies a 57.6 kbps data rate, +5 VDC bus voltage with +\/-5% tolerance, and 1.5 W typical power consumption. A 1500 VAC isolation voltage is also listed.\u003c\/p\u003e\n\u003cp\u003eThe supplied information does not establish PCI compatibility, Ethernet functionality, ControlNet network node capacity, firmware revision, or software driver version. These parameters should be verified from the applicable Allen-Bradley documentation before system integration.\u003c\/p\u003e\n\u003ch3\u003eControlNet Electrical Interface\u003c\/h3\u003e\n\u003cp\u003eThe specified 75 ohm termination requirement applies to the communication interface described in the supplied data. Incorrect termination can alter the electrical characteristics of the network segment and should be avoided.\u003c\/p\u003e\n\u003cp\u003eThe +5 VDC bus specification is stated as +\/-5%. The 1.5 W typical power consumption corresponds to approximately 300 mA at nominal 5 VDC, but the supplied specification should remain the controlling value for installation calculations.\u003c\/p\u003e\n\u003ch3\u003eOrdering Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1784-KTCX15 ControlNet ISA\/EISA Bus Interface Card\u003c\/li\u003e\n\u003cli\u003eCatalog reference: 1784KTCX15\u003c\/li\u003e\n\u003cli\u003eAlternate reference: 1784-KTCX15\/B\u003c\/li\u003e\n\u003cli\u003e2 x BNC network connectors are specified on the card\u003c\/li\u003e\n\u003cli\u003e75 ohm termination resistors are required according to the supplied specification\u003c\/li\u003e\n\u003cli\u003eHost computer, network cable, termination hardware, and software are not identified as included accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Connection Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHost Bus Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the host computer provides a compatible ISA or EISA expansion interface.\u003c\/li\u003e\n\u003cli\u003eVerify available bus resources before installing the card.\u003c\/li\u003e\n\u003cli\u003eSecure the card mechanically to prevent movement during BNC cable connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControlNet Cabling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the BNC interfaces using the applicable ControlNet cable arrangement.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified 75 ohm termination configuration.\u003c\/li\u003e\n\u003cli\u003eKeep network cabling separated from high-voltage switching conductors where practical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the host bus provides the specified +5 VDC supply within the stated +\/-5% tolerance.\u003c\/li\u003e\n\u003cli\u003eMaintain the host computer grounding arrangement during installation.\u003c\/li\u003e\n\u003cli\u003eDo not modify the card or its isolation structure to accommodate an incompatible power source.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecord the existing card identification and host configuration before replacement.\u003c\/li\u003e\n\u003cli\u003eVerify the required 16 KB memory allocation and host bus configuration.\u003c\/li\u003e\n\u003cli\u003eDo not assume compatibility with later PCI-based host architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat host bus does the 1784-KTCX15 use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied specifications identify ISA\/EISA as the host bus interface. PCI compatibility is not stated and should not be assumed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat network does this card interface with?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is identified as a ControlNet communication interface card. The supplied information specifies two BNC network connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat data rate is listed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied technical data lists a 57.6 kbps data rate. No other communication speed is confirmed by the provided information.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage does the card require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe bus voltage is specified as +5 VDC with a +\/-5% tolerance. The typical power consumption is listed as 1.5 W.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat termination is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied specification requires 75 ohm resistors for termination. The exact termination location should follow the applicable ControlNet network design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat isolation rating is specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied data specifies an isolation voltage of 1500 VAC. The test method and duration are not provided.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the card be hot swapped?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHot-swap capability is not specified. The host computer should be powered down before card removal or installation unless the complete system documentation explicitly permits otherwise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the operating temperature specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo operating temperature range is provided. The storage or operating environmental limits should therefore be confirmed from the applicable Allen-Bradley documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066449645741,"sku":"1784-KTCX15","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_1784-ktcx15_1.jpg?v=1786072518","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1784-ktcx15-allen-bradley-controlnet-isa-eisa-bus-interface-card","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}