{"product_id":"176449-09-3500-70m-bently-nevada-recip-impulse-velocity-monitor-3500","title":"176449-09 3500\/70M Bently Nevada Recip Impulse Velocity Monitor 3500","description":"\u003cp\u003eConfigured for reciprocating machinery vibration analysis in 3500 monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/70M 176449-09\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3500\/70M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRecip Impulse Velocity Monitor) provides direct physical and electrical execution of seismic transducer signal conditioning and mechanical fault detection.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/70M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e176449-09\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRecip Impulse Velocity Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500 System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/70M (176449-09)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 x 25.6 x 24.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult 3500 system manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem-dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/70M module utilizes specialized signal processing to monitor high-frequency impulse acceleration and reciprocating velocity. Eddy-current probe scaling is not applicable for this seismic-input module; however, signal path calibration is required to align transducer input with crankcase or crosshead vibration signatures. Gap voltage validation is irrelevant for seismic inputs, but installers must perform sensor sensitivity checks to confirm transducer input signals reach the module within specified linear ranges. Cross-talk suppression is maintained through internal channel isolation, preventing signal corruption in multi-channel reciprocating compressor installations.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 3500\/70M Recip Impulse Velocity Monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAppropriate I\/O module for seismic sensor termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation for configuration and signal processing logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the 3500 rack power is isolated before inserting the module into the designated slot to prevent backplane bus surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeismic Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect seismic transducers to the I\/O module using shielded cabling to reduce electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the rack to the system ground bus to prevent ground loops, which can distort low-level seismic vibration measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogic Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the 3500 Rack Configuration software to map sensor inputs to the required measurement parameters for reciprocating machine components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3500\/70M hot-swappable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the monitor supports hot-swapping within the 3500 rack system, provided the procedure aligns with local maintenance safety protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this monitor handle non-reciprocating machinery?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is purpose-built for reciprocating compressor dynamics; utilizing it for rotating equipment may yield incorrect data due to signal processing logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are alarm setpoints managed?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSetpoints are defined within the 3500 configuration software based on the measured impulse and velocity thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre sensors included with the module?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the module is a signal processing monitor; seismic transducers must be procured and installed separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the impulse velocity parameter?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt allows for the detection of high-frequency mechanical impacts typically associated with crosshead, valve, or rod-drop faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify channel operation?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the 3500 Rack Interface Module (RIM) diagnostic screens to confirm channel \"OK\" status and real-time vibration values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor four different machine points?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the four channels are independently configurable, allowing monitoring of four distinct vibration measurement locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the monitor backward compatible?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is compatible with 3500 systems; however, verify the rack firmware version against the module requirements in the technical manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378087649453,"sku":"3500\/70M 176449-09","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-3500-70m-176449-09-recip-impulse-velocity-monitor-0te3jbc4wu3.jpg?v=1764225466","url":"https:\/\/www.maxwellplc.com\/ru\/products\/176449-09-3500-70m-bently-nevada-recip-impulse-velocity-monitor-3500","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}