{"product_id":"1763-l16bwa-allen-bradley-micrologix-1100-16-point-controller","title":"1763-L16BWA Allen-Bradley MicroLogix 1100 16 Point Controller","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1763-L16BWA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1763-L16BWA\u003c\/strong\u003e MicroLogix 1100 Programmable Controller, operates as a compact control component for processing digital, analog, and relay output signals within MicroLogix automation systems.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Controller Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1763-L16BWA is a MicroLogix 1100 small logic controller integrating digital inputs, analog input channels, and isolated relay outputs in a single controller package. The unit operates with 120\/240 VAC input power and provides embedded I\/O functions for compact machine control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1763-L16BWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e1763L16BWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.8 x 11 x 8.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e52 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e10 x 24 VDC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e2 x 0-10 VDC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e6 isolated relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e1 A continuous current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1.5 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Nominal Impedance\u003c\/td\u003e\n\u003ctd\u003e3.1 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Memory\u003c\/td\u003e\n\u003ctd\u003eBattery-backed RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControlLogix and EtherNet\/IP Communication Capability\u003c\/h3\u003e\n\u003cp\u003eThe MicroLogix 1100 controller uses Allen-Bradley industrial communication architecture for controller-to-device data exchange and remote monitoring functions. The platform supports messaging operations between controllers, HMIs, and supervisory systems through supported communication interfaces.\u003c\/p\u003e\n\u003cp\u003eThe controller design supports I\/O density scaling for compact automation systems. Firmware flash compatibility must be verified when replacing controllers or integrating the unit into existing MicroLogix applications.\u003c\/p\u003e\n\u003ch3\u003eIntegrated I\/O and Control Functions\u003c\/h3\u003e\n\u003cp\u003eThe 1763-L16BWA combines multiple signal types within one controller body. The embedded 24 VDC digital inputs support standard field device monitoring, while high-speed inputs can process pulse signals from devices such as encoders or flow measurement equipment.\u003c\/p\u003e\n\u003cp\u003eThe two analog input channels support 0-10 VDC signals for sensor acquisition. Relay outputs provide individually isolated switching channels for connected loads. The controller supports functions including PID instructions, high-speed counter configuration, and controller messaging operations.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1763-L16BWA MicroLogix 1100 Controller\u003c\/li\u003e\n\u003cli\u003e1 x Controller identification label\u003c\/li\u003e\n\u003cli\u003e1 x Installed non-volatile memory system\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation documentation package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eController Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller inside an enclosure suitable for industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain clearance around ventilation areas to prevent excessive heat accumulation.\u003c\/li\u003e\n\u003cli\u003eVerify mounting position and mechanical fixing before wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect 120\/240 VAC input power according to the controller wiring requirements.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage AC conductors.\u003c\/li\u003e\n\u003cli\u003eUse proper grounding methods to reduce EMI interference.\u003c\/li\u003e\n\u003cli\u003eConfirm polarity and voltage range before applying field signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConfiguration and Maintenance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify I\/O addressing before downloading controller programs.\u003c\/li\u003e\n\u003cli\u003eCheck firmware compatibility between software tools and controller hardware.\u003c\/li\u003e\n\u003cli\u003eMaintain application backups before firmware updates or controller replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of controller is the 1763-L16BWA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1763-L16BWA is a MicroLogix 1100 programmable controller with integrated digital inputs, analog inputs, and relay outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many I\/O points are included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller provides 18 integrated I\/O points consisting of 10 digital inputs, 2 analog inputs, and 6 relay outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply does the controller require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1763-L16BWA operates from a 120\/240 VAC input power source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model include analog inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The controller includes two analog input channels supporting 0-10 VDC signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre the relay outputs isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The six relay outputs are individually isolated for connection to external field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the digital inputs process high-speed signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Four digital inputs support high-speed signal processing functions within the controller configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat memory type is used by the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller uses non-volatile battery-backed RAM for application data retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation precautions are required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper grounding, signal separation, voltage verification, and firmware compatibility checks are required before operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066425233581,"sku":"1763-L16BWA","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1763-L16BWA-0.jpg?v=1786454547","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1763-l16bwa-allen-bradley-micrologix-1100-16-point-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}