{"product_id":"1756-of6ci-allen-bradley-isolated-analog-output-module-controllogix","title":"1756-OF6CI Allen-Bradley Isolated Analog Output Module ControlLogix","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eAllen-Bradley 1756-OF6CI\u003c\/strong\u003e serves as the primary \u003cstrong\u003e1756-OF6CI\u003c\/strong\u003e isolated analog output module used to generate six electrically isolated current-loop output signals within ControlLogix systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eModel and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe supplied data identifies 1756-OF6CI as a ControlLogix isolated analog output module with six isolated output points. The module is configured for current-loop signal generation and interfaces with the ControlLogix backplane.\u003c\/p\u003e\n\u003cp\u003eNo additional suffix decoding is established by the supplied technical information. Therefore, no functional meaning is assigned to undocumented model characters.\u003c\/p\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-OF6CI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Analog Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Analog Output Module with Current Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e6-Point Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 5 VDC\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 24 VDC\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.9 W at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum power dissipation: 4.9 W at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e14.5 x 14 x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBackplane and Output Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 1756-OF6CI uses the ControlLogix backplane for module power and system communication. The specified backplane current is 250 mA at 5 VDC and 300 mA at 24 VDC.\u003c\/p\u003e\n\u003cp\u003eSix isolated analog output points are provided. The isolation separates output circuits from one another according to the module design, limiting direct electrical interaction between independent current-loop channels.\u003c\/p\u003e\n\u003cp\u003eThe maximum stated power dissipation is 4.9 W at 60 deg C. Cabinet thermal calculations should account for this value when multiple modules are installed in the same chassis.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1756-OF6CI isolated analog output module\u003c\/li\u003e\n\u003cli\u003eNo separate power supply is specified as part of the module\u003c\/li\u003e\n\u003cli\u003eNo separate communication adapter is specified as part of the module\u003c\/li\u003e\n\u003cli\u003eNo additional terminal assembly is identified in the supplied data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the ControlLogix chassis before module installation or removal unless the applicable system documentation explicitly permits the operation.\u003c\/li\u003e\n\u003cli\u003eVerify chassis power and backplane loading before adding the module.\u003c\/li\u003e\n\u003cli\u003eKeep analog output wiring separated from high-voltage switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eUse shielded signal wiring where the connected current-loop application requires noise control.\u003c\/li\u003e\n\u003cli\u003eGround cable shields according to the plant grounding scheme and the applicable ControlLogix installation documentation.\u003c\/li\u003e\n\u003cli\u003eConfirm each field connection against the wiring information for the specific 1756-OF6CI installation.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the electrical limits of the connected current-loop devices.\u003c\/li\u003e\n\u003cli\u003eConsider the stated 4.9 W maximum power dissipation when evaluating cabinet heat loading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many analog outputs does the 1756-OF6CI provide?\u003c\/strong\u003e\u003cbr\u003eThe module provides six isolated analog output points. The supplied data identifies the outputs as current-loop outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAre the six output points isolated?\u003c\/strong\u003e\u003cbr\u003eYes. The supplied product information specifies a six-point isolated analog output configuration for the 1756-OF6CI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the 5 VDC backplane current?\u003c\/strong\u003e\u003cbr\u003eThe specified backplane current at 5 VDC is 250 mA. This value should be included when calculating ControlLogix chassis loading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the 24 VDC backplane current?\u003c\/strong\u003e\u003cbr\u003eThe specified backplane current at 24 VDC is 300 mA. Use this value for the applicable ControlLogix power budget.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum power dissipation?\u003c\/strong\u003e\u003cbr\u003eMaximum power dissipation is specified as 4.9 W at 60 deg C. Cabinet thermal calculations should account for this heat load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the module have independent power consumption?\u003c\/strong\u003e\u003cbr\u003eNo separate power consumption figure is supplied. The available electrical data specifies backplane current and maximum power dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan output wiring share high-voltage cable routes?\u003c\/strong\u003e\u003cbr\u003eAnalog output wiring should be physically separated from high-voltage switching conductors where practical to reduce electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the module provide Ethernet communication directly?\u003c\/strong\u003e\u003cbr\u003eThe supplied specifications identify the unit as a ControlLogix analog output module and do not specify an independent Ethernet interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066421203117,"sku":"1756-OF6CI","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1756-OF6CI-0.jpg?v=1786351022","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1756-of6ci-allen-bradley-isolated-analog-output-module-controllogix","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}