{"product_id":"1747-l553-allen-bradley-slc-500-series-slc-5-05-64k-controller","title":"1747-L553 Allen-Bradley SLC 500 Series SLC 5\/05 64K Controller","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1747-L553\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1747-L553\u003c\/strong\u003e SLC 5\/05 Controller, operates as a dedicated PLC processor component for executing ladder logic programs and managing Ethernet, RS-232, and remote I\/O communication within SLC 500 control platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Revision Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 1747-L553 belongs to the Allen-Bradley SLC 5\/05 processor family. This controller provides CPU execution, user memory storage, communication interfaces, and discrete\/analog I\/O management for SLC 500 modular systems.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1747-L553\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSLC 5\/05 64K Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e25 x 16.5 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eSLC 5\/05 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e64 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Software\u003c\/td\u003e\n\u003ctd\u003eRSLogix 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Function\u003c\/td\u003e\n\u003ctd\u003eBOOTP Enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Protocols\u003c\/td\u003e\n\u003ctd\u003eDF1 Full Duplex, DF1 Half Duplex, DF1 Radio Modem, DH-485, ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e8192 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Analog I\/O\u003c\/td\u003e\n\u003ctd\u003e480 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e4096 Inputs \/ 4096 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% RH maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type\u003c\/td\u003e\n\u003ctd\u003eFlash EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Speed\u003c\/td\u003e\n\u003ctd\u003e0.9 ms\/K instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Capacity\u003c\/td\u003e\n\u003ctd\u003e3 local chassis \/ maximum 30 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1747-L553 processor module provides central control execution for SLC 500 modular chassis systems. It communicates with installed I\/O modules through the SLC backplane and supports Ethernet and serial communication channels for programming, diagnostics, and remote data exchange.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Function\u003c\/td\u003e\n\u003ctd\u003eLadder logic execution and system control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eSLC 500 modular chassis mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Channel 1\u003c\/td\u003e\n\u003ctd\u003eEthernet 10\/100 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Channel 0\u003c\/td\u003e\n\u003ctd\u003eRS-232 serial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Interface\u003c\/td\u003e\n\u003ctd\u003eRSLogix 500 software environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Backup\u003c\/td\u003e\n\u003ctd\u003eFlash EEPROM storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Handling\u003c\/td\u003e\n\u003ctd\u003eLocal and remote I\/O control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact Flash Support\u003c\/td\u003e\n\u003ctd\u003eOptional memory card capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1747-L553 applies Allen-Bradley PLC architecture characteristics, including Ethernet communication capability and deterministic controller-to-device data exchange. The Ethernet interface supports BOOTP configuration, while the RS-232 channel supports multiple DF1 communication modes and DH-485 networks.\u003c\/p\u003e\n\u003cp\u003eThe controller supports firmware flash compatibility within the SLC 5\/05 family. Proper revision matching between processor firmware, RSLogix 500 software, and connected communication devices is required for system operation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe shipment configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1747-L553 SLC 5\/05 Processor Module\u003c\/li\u003e\n\u003cli\u003e1 x Factory processor assembly\u003c\/li\u003e\n\u003cli\u003e1 x Product identification label\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional components required for a complete SLC 500 system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSLC 500 chassis assembly\u003c\/li\u003e\n\u003cli\u003eCompatible SLC power supply\u003c\/li\u003e\n\u003cli\u003eSLC I\/O modules\u003c\/li\u003e\n\u003cli\u003eProgramming communication cable or Ethernet connection equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eProcessor Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the processor module into the designated SLC 500 chassis slot.\u003c\/li\u003e\n\u003cli\u003eConfirm chassis power is removed before module insertion or removal.\u003c\/li\u003e\n\u003cli\u003eEnsure the module locking tabs are fully engaged.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommunication Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse shielded communication cables where required by the installation environment.\u003c\/li\u003e\n\u003cli\u003eSeparate communication wiring from high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet cable termination and network addressing before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSystem Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm processor firmware revision compatibility with RSLogix 500 software.\u003c\/li\u003e\n\u003cli\u003eVerify memory configuration before downloading application programs.\u003c\/li\u003e\n\u003cli\u003eCheck local and remote I\/O addressing after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the main function of the 1747-L553 processor?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1747-L553 executes SLC 500 control programs and manages communication between the processor, I\/O modules, and connected networks.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhich programming software is used with the 1747-L553?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe controller is configured and programmed using RSLogix 500 software with compatible SLC 5\/05 firmware revisions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat communication ports are available on this processor?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module provides Ethernet communication and an RS-232 serial port supporting DF1, DH-485, and ASCII protocols.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes the 1747-L553 support remote I\/O systems?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes. The processor supports remote I\/O communication with up to 4096 input points and 4096 output points.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat memory type is used in the 1747-L553?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe controller uses Flash EEPROM technology for application program storage and firmware management.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan the 1747-L553 replace other SLC 5\/05 processors?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReplacement depends on memory size, firmware revision, application requirements, and communication configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat temperature range can the processor operate in?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified operating temperature range is 0 to 60 deg C for normal installation conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes the controller support Ethernet programming connections?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes. The Ethernet interface supports controller communication, programming access, and BOOTP network configuration.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066410258605,"sku":"1747-L553","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1747-L553-0.jpg?v=1785929269","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1747-l553-allen-bradley-slc-500-series-slc-5-05-64k-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}