{"product_id":"1746-io12-a-allen-bradley-slc-500-combination-input-output-module","title":"1746-IO12\/A Allen-Bradley SLC 500 Combination Input\/Output Module","description":"\u003cp\u003eConfigured for mixed discrete signal interfacing in industrial automation hardware racks, the \u003cstrong\u003eAllen-Bradley 1746-IO12\/A\u003c\/strong\u003e (\u003cstrong\u003e1746-IO12\u003c\/strong\u003e) Combination Input\/Output Module provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform Series\u003c\/strong\u003e: Allen-Bradley SLC 500 modular control chassis architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Catalog Identifier\u003c\/strong\u003e: 1746-IO12 designating a hybrid 12-point configuration comprising 6 AC inputs and 6 relay outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Revision Suffix\u003c\/strong\u003e: Revision \/A defining the baseline release specification and core component layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-IO12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 x 5.1 x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 to 90 mA at 5 V DC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eSix (6) 120 V AC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003eSix (6) relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 125 V DC; 120 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration \u0026amp; Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe module communicates discrete process data across the local SLC backplane architecture, interfacing smoothly with controller units via backplane bus communication velocity licences. Firmware flash compatibility ensures that operational updates integrate cleanly without breaking deterministic network timing. Furthermore, input\/output density scaling allows mixed signal monitoring and control expansion without introducing communication delays or processing bottlenecks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1746-IO12\/A Combination Input\/Output Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal block connector interface\u003c\/li\u003e\n\u003cli\u003e1 x Hardware documentation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChassis Slot Placement: Align the module printed circuit board firmly with the guide rails of an available slot in the SLC 500 chassis and press evenly until the backplane connector seats completely.\u003c\/li\u003e\n\u003cli\u003eWiring Segregation: Separate high-voltage 120 V AC input conductors from low-voltage control lines and relay load circuits using dedicated wire conduits to prevent electromagnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003eTerminal Torque Verification: Ensure all screw terminals on the removable block are torqued down securely on stripped copper conductors to prevent intermittent electrical contact under high vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Engineering Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do the optical isolation barriers on the 120 V AC input channels protect the internal 5 V DC backplane logic during high-voltage surges?\u003c\/p\u003e\n\u003cp\u003eA: High-dielectric optocouplers provide complete galvanic separation between the external field wiring and the internal processor logic, preventing transient voltage spikes from reaching sensitive components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary electrical consequence of exceeding the maximum contact current rating on the relay output terminals?\u003c\/p\u003e\n\u003cp\u003eA: Excessive current causes micro-welding or accelerated pitting of the mechanical relay contacts, leading to permanent contact sticking and open-circuit failures under load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the relay outputs safely switch mixed voltages, such as 24 V DC and 240 V AC, across different channels on the same module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each relay output is electrically isolated from the others, allowing independent load circuits with different voltage potentials to be controlled simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the internal RC filter network on the 120 V AC inputs mitigate high-frequency electrical noise from nearby plant machinery?\u003c\/p\u003e\n\u003cp\u003eA: The input filtering stages attenuate brief voltage spikes and high-frequency harmonic interference, ensuring that only stable, valid AC voltage levels register as true logic states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What occurs to the processor input and output data tables if module backplane communication is suddenly interrupted?\u003c\/p\u003e\n\u003cp\u003eA: The processor registers a rack fault, and output states default to pre-programmed safe behaviors or reset to zero depending on the safety configuration established in the programming software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is it necessary to install arc suppression networks across inductive loads driven by the relay outputs?\u003c\/p\u003e\n\u003cp\u003eA: Inductive loads like solenoids or motor starters generate severe back-EMF voltage spikes when switched off, which cause severe arcing and degrade the mechanical lifespan of the relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does operating the module near the upper ambient temperature limit of +60 deg C impact component lifespan?\u003c\/p\u003e\n\u003cp\u003eA: Sustained high ambient temperatures accelerate the thermal degradation of internal relay coils and electrolytic capacitors, reducing the operational lifespan of the hardware assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the SLC 500 backplane supply power for driving external field devices connected to the relay outputs?\u003c\/p\u003e\n\u003cp\u003eA: No, the backplane supplies only internal logic power, requiring an external power source to supply the current routed through the relay output contacts to the load devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066404884653,"sku":"1746-IO12","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1746-IO12_13.jpg?v=1785142919","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1746-io12-a-allen-bradley-slc-500-combination-input-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}