{"product_id":"1746-in16-c-allen-bradley-24v-ac-dc-input-module-slc-500","title":"1746-IN16\/C Allen-Bradley 24V AC\/DC Input Module SLC 500","description":"\u003cp\u003eConfigured for multi-channel discrete signal conditioning within modular control chassis, the \u003cstrong\u003eAllen-Bradley 1746-IN16\/C\u003c\/strong\u003e (\u003cstrong\u003e1746-IN16\u003c\/strong\u003e) Input Module provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform Series\u003c\/strong\u003e: Allen-Bradley SLC 500 modular rack architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Catalog Identifier\u003c\/strong\u003e: 1746-IN16 designating a 16-point digital input configuration operating on 24 V AC\/DC nominal voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Revision Suffix\u003c\/strong\u003e: Revision \/C indicating updated board layout parameters and spare parts compatibility relative to earlier baseline builds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-IN16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 x 5.1 x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.14 A at 5 V DC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Controller \u0026amp; Network Architecture\u003c\/h3\u003e\n\u003cp\u003eThe embedded hardware executes high-speed digital state acquisition by leveraging backplane bus communication velocity licences to maintain deterministic network synchronization across system racks. Firmware flash compatibility ensures seamless integration with modern configuration utilities, while dynamic I\/O density scaling supports expanded sensor topologies without introducing processing latencies.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1746-IN16\/C Input Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Front removable terminal block connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical hardware documentation sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChassis Slot Placement: Insert the printed circuit board assembly firmly into any available I\/O slot of the SLC 500 chassis, ensuring proper alignment with backplane edge connectors before securing retaining screws.\u003c\/li\u003e\n\u003cli\u003eSignal Wiring Segregation: Route all incoming field sensor lines away from high-voltage power conduits and motor drives to prevent electromagnetic coupling and spurious state switching.\u003c\/li\u003e\n\u003cli\u003eTerminal Torque Verification: Ensure all screw terminals on the removable block are torqued down securely on stripped copper conductors to prevent intermittent electrical contact during vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Engineering Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do the optical isolation barriers handle mixed AC and DC input signal sources across separate banks?\u003c\/p\u003e\n\u003cp\u003eA: Each input channel features independent optocoupler circuits that provide high dielectric separation between field devices and the internal 5 V DC backplane logic, preventing ground loops regardless of whether AC or DC sources are applied.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary electrical consequence of applying input voltages that exceed the maximum specified range?\u003c\/p\u003e\n\u003cp\u003eA: Overvoltage conditions beyond the rated threshold can saturate the input filtering stages and cause thermal degradation of the internal limiting resistors, potentially destroying the optocoupler stage if sustained.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the module handle high-frequency pulse trains from fast-acting encoders without signal distortion?\u003c\/p\u003e\n\u003cp\u003eA: No, this module is engineered for standard discrete status indication and low-frequency contact closures, meaning rapid pulse trains will experience filtering delays and state-skipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the internal filtering network mitigate high-frequency electrical noise picked up by long field wiring runs?\u003c\/p\u003e\n\u003cp\u003eA: An RC low-pass filter network on each input channel attenuates high-frequency transients and switching noise before the signal reaches the optical isolation threshold detector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What occurs to the processor input data table if the module is extracted while the chassis power is active?\u003c\/p\u003e\n\u003cp\u003eA: Live extraction disrupts backplane communication on the local bus, causing the processor to register a rack fault and freeze or clear input image tables depending on configured fault routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is it critical to use shielded twisted-pair cables when routing low-level signals through noisy industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: Shielded cabling suppresses electromagnetic and radio frequency interference, ensuring that induced voltage spikes do not cross the logic-high threshold and trigger false inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does operating the module at the upper thermal limit of +60 deg C impact component lifespan?\u003c\/p\u003e\n\u003cp\u003eA: Continuous operation near the maximum temperature rating accelerates the thermal aging of electrolytic capacitors and semiconductor junctions, increasing long-term failure rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What specific maintenance checks should be performed periodically on the removable terminal block?\u003c\/p\u003e\n\u003cp\u003eA: Technicians should inspect terminal screws for loosening caused by mechanical vibration and check for signs of oxidation or moisture ingress on exposed copper wire strands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066404688045,"sku":"1746-IN16","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1746-IN163.jpg?v=1785141962","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1746-in16-c-allen-bradley-24v-ac-dc-input-module-slc-500","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}