{"product_id":"1746-btm-a-allen-bradley-slc-500-barrel-temperature-module","title":"1746-BTM\/A Allen-Bradley SLC 500 Barrel Temperature Module","description":"\u003cp\u003eConfigured for multi-channel thermal acquisition within modular control chassis, the \u003cstrong\u003eAllen-Bradley 1746-BTM\/A\u003c\/strong\u003e (\u003cstrong\u003e1746-BTM\u003c\/strong\u003e) Barrel Temperature Module provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform Series\u003c\/strong\u003e: Allen-Bradley SLC 500 modular rack architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Catalog Identifier\u003c\/strong\u003e: 1746-BTM designating a specialized multi-input thermal processing configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Revision Suffix\u003c\/strong\u003e: Revision \/A identifying the initial baseline release configuration and factory firmware baseline.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-BTM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 x 5.1 x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA at 5 V DC, 85 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003eThermocouple (4 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Draw\u003c\/td\u003e\n\u003ctd\u003e110 mA (5 V DC), 85 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration \u0026amp; Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe module communicates temperature data across the local SLC backplane architecture, interfacing smoothly with processor units via backplane bus communication velocity licences. Firmware flash compatibility ensures that operational updates integrate cleanly without breaking deterministic network timing. Furthermore, input density scaling allows thermal monitoring expansion without introducing communication delays or processing bottlenecks.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1746-BTM\/A Barrel Temperature Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal block connector interface\u003c\/li\u003e\n\u003cli\u003e1 x Hardware documentation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChassis Insertion: Align the printed circuit board firmly with the guide rails of an available slot in the SLC 500 chassis and press evenly until the backplane connector seats completely.\u003c\/li\u003e\n\u003cli\u003eThermocouple Cabling: Terminate incoming thermocouple extension wires directly into the terminal block, maintaining correct polarity matching the thermocouple alloy types.\u003c\/li\u003e\n\u003cli\u003eShielding Practices: Ground the overall cable shields at a single low-impedance earth point outside the control cabinet to minimize electromagnetic interference on low-level analog signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Engineering Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the internal cold junction compensation circuitry maintain measurement precision across varying ambient temperatures within the enclosure?\u003c\/p\u003e\n\u003cp\u003eA: An onboard temperature sensor monitors terminal block temperature variations, allowing the processor to mathematically adjust thermocouple millivolt readings in real time to eliminate ambient thermal offset errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary operational consequence if thermocouple wire polarity is accidentally reversed during field wiring?\u003c\/p\u003e\n\u003cp\u003eA: Reversing polarity causes the measured temperature values to move inversely to actual thermal changes, driving the digital register down as ambient heat rises and triggering incorrect process alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module process non-temperature millivolt signals alongside standard thermocouple inputs?\u003c\/p\u003e\n\u003cp\u003eA: The hardware is specifically tuned and linearized for thermocouple sensor profiles, meaning raw millivolt scaling requires custom scaling logic blocks inside the processor user program.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do high-frequency electrical transients from nearby variable frequency drives affect thermocouple measurement stability?\u003c\/p\u003e\n\u003cp\u003eA: Unshielded sensor lines can pick up induced common-mode noise, causing erratic fluctuations in raw analog counts unless proper twisted-pair shielding and grounding are enforced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What occurs to the last valid temperature values in the processor data table if module backplane communication is suddenly interrupted?\u003c\/p\u003e\n\u003cp\u003eA: The processor freezes the input data table at the last received values or executes pre-programmed fault routines depending on the hardware configuration settings established in the project file.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is it critical to avoid splicing thermocouple extension wire with standard copper conductors?\u003c\/p\u003e\n\u003cp\u003eA: Introducing dissimilar copper junctions creates secondary parasitic thermocouple junctions that generate unwanted thermal EMF voltages, directly corrupting the actual temperature reading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does operating the module near the upper ambient temperature limit of +60 deg C impact long-term reliability?\u003c\/p\u003e\n\u003cp\u003eA: Sustained high ambient temperatures accelerate the degradation of internal analog components and electrolytic capacitors, reducing the operational lifespan of the measurement circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the SLC 500 backplane supply both logic and analog power requirements simultaneously through the slot connector?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module draws both 5 V DC logic power and 24 V DC analog loop power directly from the chassis backplane bus connections during active operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066402754733,"sku":"1746-BTM","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1746-BTM-255.jpg?v=1785140836","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1746-btm-a-allen-bradley-slc-500-barrel-temperature-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}