{"product_id":"1746-a10-allen-bradley-slc-500-10-slot-chassis","title":"1746-A10 Allen-Bradley SLC 500 10 Slot Chassis","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1746-A10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1746-A10\u003c\/strong\u003e SLC 500 10 Slot Chassis, operates as a dedicated hardware component for mounting and connecting SLC 500 PLC modules within the SLC 500 control platform.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Details\u003c\/h3\u003e\n\u003cp\u003eThe 1746-A10 is a 10-slot chassis designed for installation of Allen-Bradley SLC 500 series modules. The chassis provides the physical mounting structure and backplane connection required for processor, I\/O, and communication modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-A10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSLC 500 Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSLC 500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e21.2 x 48.7 x 16.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by installed SLC 500 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e10 Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley SLC 500 PLC System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Function\u003c\/td\u003e\n\u003ctd\u003ePLC module rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Function\u003c\/td\u003e\n\u003ctd\u003eModule communication and power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Backplane and Module Integration\u003c\/h3\u003e\n\u003cp\u003eThe SLC 500 chassis provides the internal backplane structure required for communication between installed PLC modules. The backplane connection supports module-to-module data exchange and distributes system power according to the requirements of installed components.\u003c\/p\u003e\n\u003cp\u003eFor SLC 500 system expansion, I\/O density scaling depends on chassis selection, processor capability, and installed module configuration. Correct module placement and power loading calculation are required during system design.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe package configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1746-A10 SLC 500 10 Slot Chassis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional SLC 500 system components are installed separately according to application requirements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSLC 500 processor modules\u003c\/li\u003e\n\u003cli\u003eSLC 500 I\/O modules\u003c\/li\u003e\n\u003cli\u003eCommunication interface modules\u003c\/li\u003e\n\u003cli\u003ePower supply modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eChassis Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the chassis on a stable panel surface with proper mechanical support.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient clearance for module insertion and removal.\u003c\/li\u003e\n\u003cli\u003eVerify chassis alignment before securing mounting hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eModule Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm module compatibility with the SLC 500 backplane before installation.\u003c\/li\u003e\n\u003cli\u003eInsert modules firmly into the chassis slots.\u003c\/li\u003e\n\u003cli\u003eRemove system power before installing or removing modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Connection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the installed power supply capacity matches the total module load.\u003c\/li\u003e\n\u003cli\u003eInspect backplane connectors for contamination or mechanical damage.\u003c\/li\u003e\n\u003cli\u003eUse proper grounding practices for the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the main function of the 1746-A10 chassis?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1746-A10 provides a 10-slot mounting frame and backplane connection structure for Allen-Bradley SLC 500 PLC modules.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHow many modules can be installed in the 1746-A10?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe chassis supports up to 10 SLC 500 modules installed in available chassis slots.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIs the 1746-A10 a processor module?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The 1746-A10 is a passive chassis assembly used for mounting and connecting SLC 500 modules.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDoes the chassis provide PLC program memory?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. Program processing and memory functions are provided by compatible SLC 500 processor modules.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan SLC 500 I\/O modules be installed directly into this chassis?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes. Compatible SLC 500 I\/O modules can be installed into the available chassis slots.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDoes the chassis require separate power supply selection?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes. The power supply must be selected according to the installed processor, I\/O, and communication module load.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIs the 1746-A10 compatible with other Allen-Bradley PLC families?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe chassis is designed specifically for the SLC 500 platform and should be matched with compatible modules.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat should be checked before replacing an existing chassis?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify slot configuration, installed module compatibility, power requirements, and backplane connection condition before replacement.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066402066605,"sku":"1746-A10","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1746-A10_13.jpg?v=1785140146","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1746-a10-allen-bradley-slc-500-10-slot-chassis","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}