{"product_id":"1734-fpd-allen-bradley-point-i-o-field-distributor-module","title":"1734-FPD Allen-Bradley POINT I\/O Field Distributor Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-FPD\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-FPD\u003c\/strong\u003e POINT I\/O Field Distributor Module, operates as a dedicated hardware component for field power segmentation and distribution within Allen-Bradley POINT I\/O control architectures.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-FPD is a POINT I\/O Field Power Distributor module designed to separate and distribute field power groups within a distributed I\/O assembly. The module allows separate field power sections to be created without interrupting the controller communication structure.\u003c\/p\u003e\n\u003cp\u003eThe module supports 10 to 28.8 VDC field power distribution, up to 120\/240 VAC compatibility, and a maximum current rating of 10 A for connected field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-FPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSingapore, United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 7.8 x 13.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eField Distributor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Range\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Compatibility\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePOINT I\/O Power Distribution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1734-FPD supports I\/O density scaling by dividing field power distribution into separate segments within a POINT I\/O system. This allows different groups of field devices to receive power from independent field supply sections.\u003c\/p\u003e\n\u003cp\u003eThe module operates as a passive field power distribution component and does not process controller data. POINT I\/O backplane communication continues through the assembled system while field power zones are separated.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control architectures using compatible POINT I\/O adapters and EtherNet\/IP based deterministic networks. Proper firmware compatibility between communication adapters, controllers, and configuration software is required during system installation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-FPD POINT I\/O Field Distributor Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional POINT I\/O components required for installation may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOINT I\/O terminal base assembly\u003c\/li\u003e\n\u003cli\u003eCompatible communication adapter\u003c\/li\u003e\n\u003cli\u003eExternal field power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on a compatible DIN rail installation.\u003c\/li\u003e\n\u003cli\u003eInstall the module within the correct position of the POINT I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eVerify terminal base connection before applying field power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm field power voltage range before connection.\u003c\/li\u003e\n\u003cli\u003eSeparate field power groups according to system design requirements.\u003c\/li\u003e\n\u003cli\u003eUse suitable wiring methods for the connected load current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSystem Verification\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCheck power distribution status after installation.\u003c\/li\u003e\n\u003cli\u003eConfirm correct field power separation between I\/O groups.\u003c\/li\u003e\n\u003cli\u003eVerify communication operation after modifying the POINT I\/O assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFirmware and Network Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1734-FPD functions within the Allen-Bradley POINT I\/O modular platform and supports distributed control installations requiring segmented field power management.\u003c\/p\u003e\n\u003cp\u003eThe module does not provide communication processing or signal conversion functions. Its operation depends on the installed POINT I\/O assembly, terminal base configuration, and connected field power supply arrangement.\u003c\/p\u003e\n\u003cp\u003eSystem expansion should consider available field power capacity, adapter limitations, and overall I\/O density requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the 1734-FPD?\u003c\/p\u003e\n\u003cp\u003eThe module distributes and separates field power sections within a POINT I\/O assembly without processing I\/O signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 1734-FPD communicate with the controller?\u003c\/p\u003e\n\u003cp\u003eNo. The module is a field power distribution component and does not exchange controller data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage range can the module distribute?\u003c\/p\u003e\n\u003cp\u003eThe module supports field power from 10 to 28.8 VDC according to the provided specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the module be installed on DIN rail?\u003c\/p\u003e\n\u003cp\u003eYes. The POINT I\/O Field Distributor module is designed for DIN rail mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum current rating?\u003c\/p\u003e\n\u003cp\u003eThe module supports a maximum field current rating of 10 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module replace a POINT I\/O adapter?\u003c\/p\u003e\n\u003cp\u003eNo. The module requires a compatible POINT I\/O communication adapter within the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan field power groups be separated using this module?\u003c\/p\u003e\n\u003cp\u003eYes. The module allows field power segmentation between different POINT I\/O sections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat should be checked before installation?\u003c\/p\u003e\n\u003cp\u003eVerify terminal base compatibility, field voltage requirements, and wiring arrangement before applying power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399248557,"sku":"1734-FPD","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-FPD3.jpg?v=1784729655","url":"https:\/\/www.maxwellplc.com\/ru\/products\/1734-fpd-allen-bradley-point-i-o-field-distributor-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}