{"product_id":"150-f780nbe-allen-bradley-bulletin-150-smc-flex-smart-motor-controller","title":"150-F780NBE Allen-Bradley Bulletin 150 SMC Flex Smart Motor Controller","description":"\u003cp\u003eConfigured for high-current three-phase motor soft starting and controlled torque acceleration in industrial power control enclosures, the \u003cstrong\u003eAllen-Bradley 150-F780NBE\u003c\/strong\u003e (\u003cstrong\u003e150-F780\u003c\/strong\u003e Solid-State Soft Starter) provides direct physical\/electrical execution. The internal power structure handles continuous full-load operating currents up to 780 A across main line supply voltages from 200 to 480 VAC. Silicon-controlled rectifier (SCR) gate triggering modulates output phase angles to regulate starting current spikes, protecting motor windings and mechanical power transmission components during acceleration cycles.\u003c\/p\u003e\n\u003ch3\u003eCatalog Designation \u0026amp; Parameter Mapping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150-F\u003c\/strong\u003e: Specifies the Bulletin 150 SMC Flex solid-state soft starter controller platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e780\u003c\/strong\u003e: Designates the 780 A nominal operational current rating for standard inline load wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Standard open enclosure structural construction (IP00 rated) for cabinet integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Operating main input line voltage specification of 200...480 VAC, 3-Phase, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: Control circuit operating power voltage rating designated for 100...120 VAC (50\/60 Hz).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: Base controller hardware assembly without factory-installed option card modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Operating Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F780NBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 W (Control Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd\u003e780 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power\u003c\/td\u003e\n\u003ctd\u003e600 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage Ue\u003c\/td\u003e\n\u003ctd\u003e200...480 VAC, 3-Phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Voltage Us\u003c\/td\u003e\n\u003ctd\u003e100...120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eOpen Frame (IP00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Communication \u0026amp; Backplane Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe soft starter links directly to Allen-Bradley ControlLogix and CompactLogix programmable automation controllers through optional DPI communication adapters. Operating over EtherNet\/IP deterministic networks, the controller cyclically broadcasts line currents, operating thermal percentages, and hardware status parameters. Microprocessor firmware flash compatibility ensures synchronized SCR firing pulses across all three power phases, reducing supply voltage sags and optimizing I\/O density scaling during network-triggered start or stop commands.\u003c\/p\u003e\n\u003ch3\u003eItemized Dispatch List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 150-F780NBE SMC Flex Soft Starter Module\u003c\/li\u003e\n\u003cli\u003e1 x Set of Main Power Terminal Protective Barriers\u003c\/li\u003e\n\u003cli\u003e1 x Panel Cutout and Hole Placement Mounting Sheet\u003c\/li\u003e\n\u003cli\u003e1 x Printed Engineering Installation Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Wiring \u0026amp; Enclosure Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCabinet Orientation and Clearances\n\u003cul\u003e\n\u003cli\u003eSecure the chassis vertically against a bare metal, unpainted grounding panel inside an IP54 enclosure.\u003c\/li\u003e\n\u003cli\u003eProvide a minimum vertical clearance of 150 mm both above and below the starter frame for unhindered air convection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConductor Routing and Grounding\n\u003cul\u003e\n\u003cli\u003eRoute low-voltage 110\/120 VAC control wiring in separate metal raceways away from 3-phase line power cables.\u003c\/li\u003e\n\u003cli\u003eConnect the primary protective earth grounding lug directly to the central panel enclosure earth ground bar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions and Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific control voltage does the 150-F780NBE terminal block accept?\u003c\/p\u003e\n\u003cp\u003eThe control terminals require a single-phase supply voltage rated at 100...120 VAC at 50 Hz or 60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous operational current capacity of this soft starter model?\u003c\/p\u003e\n\u003cp\u003eThe unit provides a continuous full-load current rating of 780 A across 200...480 VAC 3-phase power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 150-F780NBE feature integrated bypass contactors?\u003c\/p\u003e\n\u003cp\u003eYes, internal bypass contactors engage after motor acceleration is complete to reduce heat generation across power SCRs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the internal operating firmware be flashed via communication networks?\u003c\/p\u003e\n\u003cp\u003eYes, onboard logic supports firmware flash compatibility via DPI adapters using standard industrial network tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environment requires an additional enclosure for the 150-F780NBE?\u003c\/p\u003e\n\u003cp\u003eBecause the chassis is an Open IP00 frame design, it must be installed inside a protective enclosure for all industrial uses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit monitor thermal overload conditions on connected motors?\u003c\/p\u003e\n\u003cp\u003eEmbedded electronic overload algorithms calculate thermal capacity based on measured phase currents and programmed motor parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre signal terminals galvanically isolated from internal power circuits?\u003c\/p\u003e\n\u003cp\u003eYes, internal control board transformers and optocouplers isolate low-voltage control terminals from line-voltage power circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is a hardware fault condition reset on this controller?\u003c\/p\u003e\n\u003cp\u003eFaults are cleared by sending a reset signal across terminal logic inputs, cycling control voltage power, or issuing a network reset command.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066396037293,"sku":"150-F780NBE","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_1-4_9aa595e3-ba44-4e87-b251-e36c0e0153e0.jpg?v=1786074213","url":"https:\/\/www.maxwellplc.com\/ru\/products\/150-f780nbe-allen-bradley-bulletin-150-smc-flex-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}