{"product_id":"150-f43nbd-allen-bradley-smc-flex-series-smart-motor-controller","title":"150-F43NBD Allen-Bradley SMC Flex Series Smart Motor Controller","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 150-F43NBD\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e150-F43NBD\u003c\/strong\u003e Smart Motor Controller, operates as a dedicated hardware component for solid-state soft starting, current limiting, and braking control within 3-phase AC motor systems.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Index\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150-F\u003c\/strong\u003e: Bulletin 150 SMC Flex solid-state motor controller architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e43\u003c\/strong\u003e: 43 A continuous rating profile supporting 7.5 to 30.0 hp motors at 460 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Open enclosure layout designed for internal industrial cabinet integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: 200...480 VAC 3-phase line input operating range at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: 100...240 VAC control circuit input voltage requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F43NBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24.0 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Internal Control Dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current\u003c\/td\u003e\n\u003ctd\u003e43 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e460 VAC (Input Line: 200...480 VAC, 3-Phase, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e30 hp (7.5 to 30.0 hp at 460 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Style\u003c\/td\u003e\n\u003ctd\u003eOpen Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Modes\u003c\/td\u003e\n\u003ctd\u003eSoft Start, Current Limit, Braking Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Communication \u0026amp; Parameter Integration\u003c\/h3\u003e\n\u003cp\u003eThe unit interfaces with higher-level Logix controllers via optional communication modules, supporting EtherNet\/IP deterministic networks for real-time telemetry and control execution. Embedded parameters map directly into controller I\/O trees, maintaining firmware flash compatibility across network nodes to prevent configuration mismatches during system initialization.\u003c\/p\u003e\n\u003ch3\u003ePackage Delivery Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 150-F43NBD Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Setup \u0026amp; Mounting Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Orientation\n\u003cul\u003e\n\u003cli\u003eMount the open-style controller vertically inside a suitable NEMA or IP rated enclosure to allow unrestricted vertical airflow across the heat sink.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMain Power Line Cabling\n\u003cul\u003e\n\u003cli\u003eTerminate 3-phase AC power leads to line terminals L1, L2, L3 and motor leads to T1, T2, T3 using correctly rated torque tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eControl Supply Separation\n\u003cul\u003e\n\u003cli\u003eRoute the 100...240 VAC control supply wiring through isolated conduits separate from high-power load cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSystem Protective Grounding\n\u003cul\u003e\n\u003cli\u003eSecure a low-impedance ground bonding jumper from the panel ground bus directly to the chassis ground terminal before applying line voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Engineering FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum continuous current capacity of the 150-F43NBD?\u003c\/p\u003e\n\u003cp\u003eThe controller provides a maximum continuous output current rating of 43 A for 3-phase induction motor loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control voltage supply is required for internal logic execution?\u003c\/p\u003e\n\u003cp\u003eAn independent single-phase control voltage input of 100...240 VAC at 50\/60 Hz is required across the control terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan main power connections be changed while control power is present?\u003c\/p\u003e\n\u003cp\u003eNo, both main 3-phase line power and control power must be completely de-energized before making or breaking terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat motor power range does this controller manage at 460 VAC line input?\u003c\/p\u003e\n\u003cp\u003eThe hardware manages 3-phase induction motor loads rated from 7.5 hp up to 30.0 hp at 460 VAC operating line potential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 150-F43NBD unit support dynamic motor stopping routines?\u003c\/p\u003e\n\u003cp\u003eYes, the integrated firmware includes braking control modes designed to bring connected inductive loads to a controlled stop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an additional protective housing needed for panel mounting?\u003c\/p\u003e\n\u003cp\u003eYes, because this unit is an open enclosure design, it must be mounted inside a protected industrial enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are communication parameters synchronized across network cards?\u003c\/p\u003e\n\u003cp\u003eOptional communication modules slot into dedicated internal ports, maintaining firmware flash compatibility for seamless integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input line voltage range can be applied to the main power terminals?\u003c\/p\u003e\n\u003cp\u003eThe main power circuit accepts 3-phase AC operating voltages from 200 VAC up to 480 VAC at 50\/60 Hz nominal frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066388009133,"sku":"150-F43NBD","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_5-0_1468472a-b601-487c-a957-8061ffd5beb5.jpg?v=1786074540","url":"https:\/\/www.maxwellplc.com\/ru\/products\/150-f43nbd-allen-bradley-smc-flex-series-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}