{"title":"Bently Nevada 3300XL 25mm \u0026 50mm Probes Differential Expansion","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 XL 25mm and 50mm Transducer Systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare engineered specifically for measuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDifferential Expansion (DE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon large steam turbine generator sets. These sensors track the relative thermal growth between the machine rotor and the casing, which is a critical safety parameter during startup and shutdown cycles.\u003c\/p\u003e\n\u003cp\u003eWith an extended linear range far exceeding standard proximity sensors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL high-displacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem ensures that your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Turbine Supervisory Instrumentation)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides accurate, non-contacting data. As a specialized B2B supplier, we provide the complete\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeddy current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echain—including probes, extension cables, and Proximitor sensors—to maintain compliance with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAPI 670\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards and prevent catastrophic rotor-to-stator contact.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330876-01-10-00-00-3300-xl-proximity-probe","title":"Bently Nevada 330876-01-10-00-00 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for radial vibration and axial position measurement in rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330876-01-10-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330876-01-10-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical execution of displacement sensing via eddy-current induction within 3300 XL monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Decomposition\u003c\/h3\u003e\n\u003cp\u003eThe 330876-01-10-00-00 part number indicates the following hardware configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330876: 3300 XL NSv Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e01: 5 mm probe tip diameter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 10 mm case length (threaded).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Connector assembly without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No agency approval options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330876-01-10-00-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 mm x 250 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL NSv system relies on accurate eddy-current probe scaling to translate target displacement into a voltage signal proportional to the rotor position. To ensure data integrity, the probe must be installed with a target gap voltage of -10 VDC at the Proximitor sensor output. Rotor dynamics analysis is highly sensitive to probe mounting; therefore, the assembly must be secured to a rigid bracket to prevent resonance. Furthermore, effective cross-talk suppression is achieved by maintaining specified physical spacing between adjacent probes, which prevents mutual interference of high-frequency carrier signals.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330876-01-10-00-00 5 mm NSv Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Stainless steel lock nut\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Calibration data sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Mounting\u003c\/strong\u003e: Install in a non-conductive, rigid bracket to ensure signal stability and prevent parasitic capacitance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Setting\u003c\/strong\u003e: Verify the output voltage at the Proximitor end. The probe must be adjusted until the DC gap voltage measures -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Handling\u003c\/strong\u003e: Maintain a minimum static bend radius of 25 mm to prevent impedance changes within the coaxial assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure the probe housing is electrically continuous with the machine casing unless electrical isolation is required by the monitoring system design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the probe is rated for continuous operation within a temperature range of -51 deg C to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the probe tip replaceable?\u003c\/p\u003e\n\u003cp\u003eA: No, the PPS probe tip is permanently bonded to the stainless steel housing as an integrated assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the -10 VDC gap voltage target?\u003c\/p\u003e\n\u003cp\u003eA: This target ensures the Proximitor output operates within its linear range for accurate displacement measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this probe with 3500 series monitors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the probe is connected to a compatible 3300 XL NSv Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum linear range of this probe?\u003c\/p\u003e\n\u003cp\u003eA: The linear range is 1.5 mm, which is specific to the NSv design for smaller target applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the probe housing require special shielding?\u003c\/p\u003e\n\u003cp\u003eA: No, the housing provides basic protection; however, the coaxial cable should be routed through conduit to minimize electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does material composition affect measurement?\u003c\/p\u003e\n\u003cp\u003eA: Calibration is based on 4140 steel; using different target materials will alter the probe scaling factor and require recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the consequence of a loose lock nut?\u003c\/p\u003e\n\u003cp\u003eA: A loose nut may allow the probe to vibrate or shift, causing significant measurement drift and signal noise in the monitoring data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518766932141,"sku":"330876-01-10-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330876-01-10-00-00-proximity-probe-pd1ed1b32na.jpg?v=1766977095"},{"product_id":"330851-06-000-070-50-00-05-bently-nevada-proximity-probe-3300-xl-nsv","title":"330851-06-000-070-50-00-05 Bently Nevada Proximity Probe 3300 XL NSv","description":"\u003cp\u003eThe Bently Nevada 330851-06-000-070-50-00-05 serves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute non-contacting shaft displacement and vibration measurements across 3300 XL NSv platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Matrix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330851: 3300 XL NSv Proximity Probe, 3\/8-24 UNF thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-06: 0.6 inch unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-000: 0.0 inch overall case length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-070: 7.0 inches total length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-50: FluidLoc cable option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-00: Miniature coaxial ClickLoc connector option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-05: Multiple hazardous area agency approvals option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Parameter Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-06-000-070-50-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 x 15.0 x 4.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Element (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.52 mm (60 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc structure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc miniature coaxial connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis proximity sensor operates on the eddy-current principle to track dynamic shaft behavior and rotor dynamics. The mechanical assembly converts distance parameters into high-frequency RF fields generated by the Proximitor. Field calibration relies on accurate gap voltage validation, targeting a nominal -10 VDC center-scale checkpoint for optimal linearity. Precision tip architecture provides stable eddy-current probe scaling metrics while suppressing multi-channel cross-talk in dense radial setups.\u003c\/p\u003e\n\u003ch3\u003eLogistics Packaging Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330851-06-000-070-50-00-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 3\/8-24 Brass Hex Mounting Locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Coaxial Connector Silicone Protection Boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mechanical Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement Stability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure bracket mounting achieves rigid thread engagement to eliminate case vibration harmonics that distort true target readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Position Adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdjust the mechanical insertion depth until gap voltage validation registers approximately -10 VDC at the monitor rack test points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Isolation Proportions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain an open cylindrical radius of at least 15 mm around the probe tip to prevent target anomalies from surrounding metal walls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Coupling Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHand-tighten the ClickLoc miniature coaxial connector; do not use pliers or mechanical tools to avoid crushing internal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximity probe configuration support hot-swap terminal substitution?\u003c\/p\u003e\n\u003cp\u003eYes. The probe can be physically disconnected from the extension cable while the main Proximitor and monitor rack remain energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does structural surface finish affect eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eSurface defects or microstructural variations modify electrical conductivity, altering the calibrated linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptom indicates a failure in gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eA validation reading sitting near 0 VDC or exceeding -18 VDC indicates an open circuit, short circuit, or incorrect mechanical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this model operate with any length of extension cable?\u003c\/p\u003e\n\u003cp\u003eNo. The probe must match the specific system configuration loop length to preserve factory calibration tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is cross-talk suppression managed when installing two orthogonal probes?\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum axial separation of 40 mm between probe tips when monitoring identical shaft sections to prevent RF interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operating limit of the tip material?\u003c\/p\u003e\n\u003cp\u003eThe specialized sensor tip holds structural and electrical integrity during continuous thermal exposure up to 177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external isolation barrier required for hazardous area installations?\u003c\/p\u003e\n\u003cp\u003eYes. Intrinsic safety barriers must be wired between the Proximitor sensor loop and the monitoring system rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the coaxial connector boot is omitted in humid conditions?\u003c\/p\u003e\n\u003cp\u003eMoisture ingress increases electrical leakage resistance, causing calibration drift and intermittent channel fault alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807859373,"sku":"330851-06-000-070-50-00-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-06-000-070-50-00-05-proximity-probe-pfqpq5wantv.jpg?v=1766979370"},{"product_id":"330854-080-25-00-bently-nevada-extension-cable-3300-xl","title":"330854-080-25-00 Bently Nevada Extension Cable 3300 XL","description":"\u003cp\u003eConfigured for signal transmission in 3300 XL proximity monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330854-080-25-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330854-080-25-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical\/electrical execution for connecting probes to remote Proximitor sensors.\u003c\/p\u003e\n\u003ch3\u003ePart Number Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330854 extension cable is designed to maintain the impedance matching requirements of the 3300 XL system. The specific ordering configuration is:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e080\u003c\/strong\u003e: Cable length (8.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e25\u003c\/strong\u003e: Connector\/Cable configuration (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval (None).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-080-25-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.95 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 x 30 x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, 75 Ohm nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe 330854 cable ensures signal integrity between the transducer and the Proximitor. In machinery protection applications, this cable is calibrated as part of the total probe-cable-Proximitor system, where eddy-current probe scaling is maintained across the entire loop. Correct installation is necessary to prevent signal distortion; specifically, the cable must be routed to avoid electromagnetic interference that could affect gap voltage validation (-10 VDC targets). Proper cable management contributes to cross-talk suppression by preventing capacitive coupling between parallel signal loops in the machinery housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330854-080-25-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Connector protective boots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical installation instruction sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing:\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum bend radius of 25 mm to prevent stress on the coaxial center conductor. Avoid routing near high-current motor leads or VFD cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Seating:\u003c\/p\u003e\n\u003cp\u003eEnsure ClickLoc connectors are fully engaged. A tactile and audible click confirms the mechanical lock and electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding:\u003c\/p\u003e\n\u003cp\u003eThe cable shield must remain isolated from the machine housing unless the specific application design mandates a single-point ground connection at the junction box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection:\u003c\/p\u003e\n\u003cp\u003eUse the provided connector boots to seal interfaces against moisture and oil ingress in the terminal housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan I splice this cable if it is too long?\u003c\/p\u003e\n\u003cp\u003eNo. Splicing or cutting the coaxial cable alters the characteristic impedance, which invalidates the system calibration and accuracy of the rotor dynamics data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with 3300 NSv systems?\u003c\/p\u003e\n\u003cp\u003eNo. The 330854 extension cable is specific to the 3300 XL system and uses different impedance characteristics than the NSv-specific cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of excessive cable length?\u003c\/p\u003e\n\u003cp\u003eThe total system length (probe + extension cable) is strictly calibrated. Exceeding specified length limits will cause signal attenuation and calibration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this cable in high-temperature zones?\u003c\/p\u003e\n\u003cp\u003eThe cable is rated for operation up to +177 deg C. Ensure the routing path does not expose the cable to temperatures exceeding this limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the connectors waterproof?\u003c\/p\u003e\n\u003cp\u003eThe connectors are designed for industrial use with protective boots. They are not intended for direct immersion in liquid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a faulty extension cable?\u003c\/p\u003e\n\u003cp\u003eUse a digital multimeter to verify continuity and check for high resistance or shorts between the center conductor and the shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this cable require a specific mounting orientation?\u003c\/p\u003e\n\u003cp\u003eNo, the cable is flexible, but it must be secured using appropriate cable ties to prevent fatigue caused by machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330854 cable agency-rated?\u003c\/p\u003e\n\u003cp\u003eThe -00 suffix indicates no hazardous area approvals. Always verify the site safety requirements before installation in explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518814937261,"sku":"330854-080-25-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-080-25-00-extension-cable-5rocu5wzjkd.jpg?v=1766979473"},{"product_id":"bently-nevada-330850-90-cn-3300-xl-25mm-proximitor-sensor","title":"Bently Nevada 330850-90-CN 3300 XL 25mm Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 330850-90-CN is a specialized 25mm Proximitor sensor from Bently Nevada's 3300 XL series, engineered to provide advanced signal conditioning for large-scale displacement monitoring. This module acts as the sophisticated electronic core of a proximity transducer system, converting the eddy current signals from a 25mm probe into a linear voltage output. Specifically designed for applications requiring an extended linear range, this sensor is a critical component for Turbine Supervisory Instrumentation (TSI). Its high-grade construction ensures deterministic data acquisition, allowing for the precise tracking of mechanical motion in critical rotating assets where standard 8mm systems lack the necessary measurement depth.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters and Engineering Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm Proximity Transducer System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for extended displacement up to 10 mm (approx. 400 mils)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard -24 Vdc supply with a 50mA maximum current draw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Sensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecisely calibrated to 0.787 V\/mm (20 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of handling high-frequency data up to 50 kHz for rapid transient capture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP67 rated for complete protection against dust and temporary immersion in industrial fluids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to +185°F) for extreme industrial climates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCorrosion-resistant housing with CN-specific regional certification compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced RFI\/EMI shielding to prevent data distortion in electrically noisy motor rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Deployment and System Utilization\u003c\/h3\u003e\n\u003cp\u003eThe 330850-90-CN Proximitor is the primary choice for monitoring large-bore rotating machinery, such as massive steam turbines, hydroelectric generators, and large-scale industrial process compressors.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-2248 citation-end-2248\"\u003eBecause of the 25mm system's superior linear range, this sensor is ideally suited for monitoring differential expansion—tracking the relative movement between a machine's rotor and its casing during thermal startup cycles.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is also utilized for axial (thrust) position monitoring on heavy shafts where significant movement is expected. By delivering accurate, non-contacting measurement data to Bently Nevada 3500 series protection racks, the 330850-90-CN supports automated safety interlocks and sophisticated predictive maintenance programs, ensuring long-term operational reliability in the petrochemical and power generation sectors.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518819295405,"sku":"330850-90-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330850-90-cn-proximity-sensor-yyyxuue22dt.jpg?v=1766979480"},{"product_id":"bently-nevada-330850-50-05-proximitor-sensor-3300-xl-25mm","title":"Bently Nevada 330850-50-05 Proximitor Sensor 3300 XL 25mm","description":"\u003ch3 class=\"\"\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 330850-50-05 is a high-precision signal conditioner belonging to the 3300 XL 25 mm Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard 8 mm sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis 25 mm proximitor is engineered for \"Extended Range\" applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering a much larger linear measurement window.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt functions as the electronic core of an eddy current measurement chain,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the necessary excitation for the probe and converting the resulting impedance changes into a stable,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003elinear voltage output.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis system is indispensable for monitoring massive rotating assets where significant thermal expansion or large shaft displacements occur,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that critical safety data remains accurate even during extreme mechanical shifts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Parameters and Key Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330850-50-05 is designed to maintain high linearity and temperature stability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efulfilling the requirements of API 670 for machinery protection systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e330850-50-05\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTransducer Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCalibrated specifically for 3300 XL 25 mm Proximity Probes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTotal System Length\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Meters (Option -50)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Option\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail and bulkhead mounting hardware included (Option -05)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 mm (500 mils),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estarting at approximately 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e63 mm (25 mils) from the probe face\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eScale Factor\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e787 V\/mm (20 mV\/mil)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFrequency Response\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 Hz (DC) to 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-17.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Vdc to -26 Vdc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Signal\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Vdc to -17 Vdc (Gap dependent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTechnopolymer housing provides resistance to moisture and chemical contaminants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDue to its extended measurement range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330850-50-05 is the primary choice for monitoring large-scale Turbine Supervisory Instrumentation (TSI) parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDifferential Expansion (DE)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring the relative growth between a steam turbine’s rotor and its casing during thermal cycles to prevent internal contact.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRamp Differential Expansion\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTracking shaft movement in specialized turbine designs where standard proximity sensors lack the necessary range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLarge-Scale Hydroelectric Generators\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring shaft vibration and displacement in hydro turbines where large mechanical clearances are present.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Growth Analysis\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eQuantifying the physical expansion of machine housings and supports in high-temperature process environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStructural Displacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking the movement of large industrial components in refineries and power plants where sub-millimeter precision is required over a centimeter-scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 330850-50-05 integrates seamlessly with Bently Nevada 3500 series racks, allowing for advanced diagnostic trending and automated machinery protection logic to safeguard high-value industrial infrastructure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518819852461,"sku":"330850-50-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330850-50-05-3300-xl-25-mm-proximitor-sensor-mctkx3ebbta.jpg?v=1766979500"},{"product_id":"330851-02-000-030-10-00-05-bently-nevada-3300-xl-series-proximity-probes","title":"330851-02-000-030-10-00-05 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330851-02-000-030-10-00-05\u003c\/strong\u003e serves as the primary \u003cstrong\u003e330851\u003c\/strong\u003e Proximity Probes utilized to execute long-range non-contact displacement and differential expansion measurements across 3500 Machinery Protection System platforms. This hardware generates a high-frequency eddy-current field to measure large axial displacements between the sensor tip and the rotating shaft target face.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-030-10-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 180 mm x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower supplied via associated 3300 XL Proximitor Sensor loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Linear Range\u003c\/td\u003e\n\u003ctd\u003e27.9 mm (1100 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Calibration\u003c\/td\u003e\n\u003ctd\u003eStandard AISI 4140 steel target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm sensor profile incorporates specialized eddy-current probe scaling matrices optimized for tracking large-scale mechanical shifts, such as thermal differential expansion on large steam turbine rotors. Execution requires precise gap voltage validation (-10 VDC targets) during baseline calibration to fix the physical window relative to the electrical scale factor. Due to the wide RF magnetic field generated by the 25 mm tip diameter, nearby metallic components can cause inductive distortion; hence, cross-talk suppression requires precise physical isolation distances around the sensor assembly. Maintaining proper installation boundaries ensures accurate assessment of low-frequency and high-frequency rotor dynamics across the entire expansion profile.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Framework:\u003c\/strong\u003e Coaxial extension cable shields must remain completely isolated from the machine housing and local electrical conduits. Grounding paths require single-point termination at the Proximitor sensor chassis ground plane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting Engagement:\u003c\/strong\u003e Secure the large-diameter housing into the mounting sleeve. Ensure a minimum of 5 full thread turns engagement to lock the probe assembly against continuous high-frequency machinery vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSide-Wall Clearance Limits:\u003c\/strong\u003e The 25 mm tip diameter projects a wide magnetic field array. Maintain the full unthreaded radius clearance zone specified by the factory blueprint to prevent side-wall metal interference from causing calibration errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this proximity probe be replaced via hot-swap methods while the channel monitor is online?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnecting or reconnecting the coaxial connection point while the Proximitor loop remains fully energized can cause transient voltage spikes, triggering false alerts or hardware diagnostic faults on the monitoring rack.\u003c\/p\u003e\n\u003cp\u003eQ: Why does the 25 mm probe require a significantly larger side-wall clearance than 8 mm probes?\u003c\/p\u003e\n\u003cp\u003eA: The 25 mm probe tip generates an expanded RF magnetic field to achieve its 27.9 mm linear range. Surrounding structural metals within this zone distort the eddy-current probe scaling profile unless proper clearance is maintained.\u003c\/p\u003e\n\u003cp\u003eQ: What target material must be used to maintain the factory calibration curve?\u003c\/p\u003e\n\u003cp\u003eA: The sensor loop is factory-calibrated to an AISI 4140 standard steel target. Alternate alloys modify the magnetic absorption properties and alter the millivolt-per-mil scale sensitivity.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518831255725,"sku":"330851-02-000-030-10-00-05","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-02-000-030-10-00-05-3300-xl-25-mm-proximity-probe-cxchwmfmtq1.jpg?v=1766979839"},{"product_id":"bently-nevada-330851-04-000-030-10-01-00-3300-xl-25-mm-proximity-probe","title":"Bently Nevada 330851-04-000-030-10-01-00 3300 XL 25 mm Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-04-000-030-10-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25 mm Proximity Probe, operates as a dedicated hardware component for eddy-current displacement sensing within turbine monitoring (TSI) platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330851: 25 mm Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e04: Total probe length variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e000: Unthreaded case length (0 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e030: Overall case length (30 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total system length (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e01: Connector option (Connector with housing).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-04-000-030-10-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.0 x 30.0 x 8.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop Powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinearity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm system utilizes eddy-current induction to translate displacement into a linear voltage signal. Unlike 8 mm systems, the 25 mm probe offers a linear range of 12.7 mm, suited for monitoring differential expansion and valve position. System commissioning mandates gap voltage validation; the sensor must be positioned to center the output voltage within the specific linear range defined for the 25 mm Proximitor. The internal geometry includes cross-talk suppression to maintain signal fidelity when multiple probes are installed in dense turbine casings.\u003c\/p\u003e\n\u003ch3\u003eProcurement \u0026amp; Scope of Delivery\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330851-04-000-030-10-01-00 25 mm Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard mounting nut and lock washer set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical conformance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: System operation requires a matched 3300 XL 25 mm Proximitor and extension cable to meet calibrated specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Thread the probe housing into the machine port; ensure perpendicular alignment to the target surface to prevent non-linear signal artifacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Adjustment: Use a calibrated depth micrometer to set the initial mechanical gap; monitor the DC output voltage at the Proximitor test pin during adjustment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Path: Utilize high-frequency coaxial cable; maintain isolation from AC power conduit to minimize EMI\/RFI noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Security: Ensure click-loc connectors are fully engaged until a tactile click is confirmed to maintain shielding continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Establish a low-impedance connection between the housing and the machine chassis to optimize the effectiveness of internal shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the 25 mm system range different from 8 mm systems?\u003c\/p\u003e\n\u003cp\u003eThe 25 mm probe utilizes a larger coil diameter and magnetic field profile, providing a 12.7 mm linear range required for large-scale displacement measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with standard 3300 XL 8 mm Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. The 25 mm probe has unique electrical scaling and must be matched to a dedicated 25 mm Proximitor to ensure valid output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the target gap voltage determined?\u003c\/p\u003e\n\u003cp\u003eGap voltage is set based on the specific linear range document provided with the 25 mm Proximitor, ensuring the transducer operates within its calibrated electrical window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe monitor radial shaft vibration?\u003c\/p\u003e\n\u003cp\u003eWhile technically capable, the 25 mm system is engineered for low-frequency position and expansion data, not for high-frequency rotor vibration analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe tip replaceable if damaged?\u003c\/p\u003e\n\u003cp\u003eNo. The probe tip is permanently bonded to the stainless steel housing; any impact damage necessitates replacement of the complete unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes target material composition impact output?\u003c\/p\u003e\n\u003cp\u003eYes. Factory calibration is standardized for 4140 steel. Alternative shaft materials require an electrical scale factor adjustment to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signifies a failure in the transducer circuit?\u003c\/p\u003e\n\u003cp\u003eFailure is typically identified by the monitor rack reading a \"Gap Error\" or voltage saturation at the rail (either 0 VDC or -24 VDC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 1.0 meter system length be extended in the field?\u003c\/p\u003e\n\u003cp\u003eNo. The system is calibrated at the factory for the specific 1.0 meter length; field modifications to cabling will invalidate system impedance and accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518839873709,"sku":"330851-04-000-030-10-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-04-000-030-10-01-00-3300-xl-25-mm-proximity-probe-efvf4m2gu3m.jpg?v=1766980184"},{"product_id":"330854-40-24-00-bently-nevada-extension-cable-3300-xl-25-mm","title":"330854-40-24-00 Bently Nevada Extension Cable 3300 XL 25 mm","description":"\u003cp\u003eConfigured for high-frequency signal transmission in mechanical monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330854-40-24-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330854\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm Extension Cable) provides direct electrical connectivity between proximity probes and proximal monitoring instrumentation. This component preserves the impedance characteristics required for accurate signal propagation within machine protection networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330854-40-24-00 identification corresponds to the following configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e40: Cable length (4.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24: Connector and cable configuration (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval options (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-40-24-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Passive component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm (Coaxial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Signal Dynamics and Rotor Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 25 mm system requires precise eddy-current probe scaling to function within its linear range. The 330854 extension cable acts as an impedance-matched link that prevents signal reflection, which could otherwise corrupt the diagnostic data of large-clearance machinery. Field technicians must perform gap voltage validation, targeting -10 VDC during installation to ensure that rotor dynamics, such as shaft centerline and orbital plots, are accurately processed by the monitor. Effective cross-talk suppression is achieved by keeping these cables routed separately from high-power AC lines to prevent induced noise in the transducer loop.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330854-40-24-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector caps (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation documentation kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Cable Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Utilize grounded metallic conduit for all cable runs to mitigate electromagnetic and radio frequency interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 3.0 cm to ensure the structural integrity of the coaxial dielectric and signal conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Sealing: Apply weather-resistant heat-shrink or moisture boots if the installation area is subject to high humidity or chemical exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTermination: Secure connections by tightening to finger-tight pressure; avoid the use of mechanical tools that may damage the locking mechanism.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Handling Logistics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComponents are sealed in anti-static industrial packaging to mitigate ESD events and mechanical damage during shipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material targets are supported? The transducer system is calibrated for AISI 4140 steel. Any deviation in target material magnetic permeability requires field recalibration of the probe scale factor to ensure linear output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the probe sensitivity? The 3300 XL 25 mm system provides a standard sensitivity of 3.94 V\/mm (100 mV\/mil), which is maintained through the system-wide impedance matching of this extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow often should calibration be verified? Annual verification is recommended. For critical safety loops, align verification with established site-specific maintenance cycles for rotating machinery protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe operate in hazardous environments? Yes, provided the cable is installed within an intrinsically safe loop as defined by the manufacturer's control drawings and applicable area classification standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat extension cables are compatible? Only Bently Nevada 3300 XL series cables are compatible. Unauthorized cable lengths or impedance mismatches will lead to signal attenuation and erroneous vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes unstable gap voltage? Instability is usually attributed to improper shielding, cable damage, or contaminated connectors. Verify that all connections are secure and free of oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is probe health tested? Health is validated by measuring the loop resistance and verifying the dynamic output response of the transducer system during normal machine operation or via static gap verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the expected service life? Service life is contingent on the operating environment, specifically thermal and mechanical stress levels. Under standard industrial conditions, the cable is intended for continuous, long-term duty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518848622765,"sku":"330854-40-24-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-40-24-00-3300-xl-25-mm-extension-cable-c5r334oxmg1.jpg?v=1766980383"},{"product_id":"330851-02-000-050-50-00-05-bently-nevada-proximity-probes-3300-xl-25-mm-series","title":"330851-02-000-050-50-00-05 Bently Nevada Proximity Probes 3300 XL 25 mm Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-02-000-050-50-00-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute non-contacting displacement and vibration measurements across 3500 Machinery Protection System platforms. It transforms micro-level mechanical shaft movements into corresponding electrical voltage variables processed continuously by monitoring hardware units.\u003c\/p\u003e\n\u003ch3\u003eSuffix Array Mapping\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330851\u003c\/strong\u003e: 3300 XL 25 mm Proximity Probe, 1-12 UNF thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Case thread option (English thread, fully threaded case)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-000\u003c\/strong\u003e: Unthreaded length option (0.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-050\u003c\/strong\u003e: Overall case length option (5.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-50\u003c\/strong\u003e: Total length option (5.0 m \/ 16.4 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Connector option (Miniature coaxial clickloc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Agency approval option (Multiple hazardous area certifications, ATEX \/ IECEx \/ CSA intrinsic safety)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-000-050-50-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 25.0 cm x 7.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 mm (500 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.787 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer component driven by Proximitor Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe heavy-duty 25 mm transducer architecture relies on precise eddy-current probe scaling to execute large-displacement tracking on massive industrial shafts. Field calibration routines demand exact gap voltage validation (-10 VDC targets) representing the definitive geometric center of the linear voltage window. When mapping high-density layouts for multi-plane rotor dynamics analysis, field technicians must adhere to spacing minimums to ensure absolute cross-talk suppression. Unshielded overlapping radio frequency fields between neighboring large-diameter tips distort the induction curve and corrupt the monitor logic.\u003c\/p\u003e\n\u003ch3\u003eKit Packaging Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330851-02-000-050-50-00-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Prefitted miniature coaxial clickloc male connector terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Heavy-duty locknuts (1-12 UNF) for structural positioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Hazardous area installation leaflet with certified control drawings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement Alignment\u003c\/strong\u003e: Insert and turn the large 1-12 UNF threaded case into the mounting bracket manually to verify clean engagement before applying mechanical tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Center Adjustments\u003c\/strong\u003e: Spin the probe body into the holder assembly while tracking the sensor loop voltage until reaching the standard target value of -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Strain Routing\u003c\/strong\u003e: Secure the 5.0 m integral coaxial lead with adequate slack inside conduit to prevent insulation shear or tight bending radius failure at the barrel exit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Isolation\u003c\/strong\u003e: Isolate the outer coaxial jacket braid from machine casing contact, grounding the shield strictly at the Proximitor enclosure barrier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePacking \u0026amp; Delivery Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTransit Frame: 2-7 days when payment finish\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistribution Channels: Dispatched internationally through premium express carriers DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhysical Protection: Packaged in anti-static industrial packaging featuring shock-absorbent multi-layer containment enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Queries \u0026amp; Answers\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific electrical parameter signifies that the probe gap is correctly calibrated?\u003c\/p\u003e\n\u003cp\u003eThe electrical field calibration requires adjusting the sensor position until the raw DC voltage at the Proximitor reads -10 VDC, securing the exact midpoint of the linear displacement zone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe component be hot-swapped while the machinery monitor is under power?\u003c\/p\u003e\n\u003cp\u003eYes, the probe is a passive transducer and can be decoupled from the cable link while live. However, the sudden voltage drop will trigger rack alarms if bypass locks are not set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does targeting alternative metal substrates affect the factory scale factor?\u003c\/p\u003e\n\u003cp\u003eThe internal eddy-current loop is calibrated exclusively for AISI 4140 steel targets. Testing alternative metals changes the magnetic flux properties, introducing significant scaling calculation errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific industrial protection does the -00 connector option provide?\u003c\/p\u003e\n\u003cp\u003eThe -00 option designates a bare miniature coaxial clickloc interface without an external sleeve protector, requiring explicit housing enclosure or separate potting protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this hardware module draw direct operational current from the monitoring rack backplane?\u003c\/p\u003e\n\u003cp\u003eNo, the probe contains no active electrical components. It acts as a passive reactive load driven entirely by high-frequency excitation voltage generated by the external Proximitor Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical spacing is mandatory to ensure complete cross-talk suppression between probes?\u003c\/p\u003e\n\u003cp\u003eProbes must maintain a minimum physical distance equivalent to at least three tip diameters from any adjacent probe or unexpected structural metal to preserve magnetic field integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat performance issue occurs if the total cable length is modified outside of specifications?\u003c\/p\u003e\n\u003cp\u003eThe system demands a matching 5.0 m or 9.0 m total system length. Arbitrary cable cutting or extensions throw off the tuned loop impedance, which invalidates the 0.787 V\/mm linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical temperature boundaries governing the probe tip and internal wire?\u003c\/p\u003e\n\u003cp\u003eThe 25 mm tip structure and matching coaxial lead are structurally rated to withstand field conditions ranging from a minimum of -51 deg C up to a maximum limit of +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518849966253,"sku":"330851-02-000-050-50-00-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-02-000-050-50-00-05-3300-xl-25-mm-proximity-probe-ftob3tiiky4.jpg?v=1766980418"},{"product_id":"330854-080-24-05-bently-nevada-3300-xl-25-mm-extension-cable","title":"330854-080-24-05 Bently Nevada 3300 XL 25 mm Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330854-080-24-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330854\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for non-contacting displacement and vibration measurements within 3300 XL 25 mm Proximity Transducer Systems. It transmits radio frequency signals between the 25 mm proximity probe and the Proximitor sensor without modifying critical loop impedance parameters.\u003c\/p\u003e\n\u003ch3\u003eOption Key Configurations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330854\u003c\/strong\u003e: 3300 XL 25 mm Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-080\u003c\/strong\u003e: Cable length option (8.0 m \/ 26.2 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-24\u003c\/strong\u003e: Connector and cable option (Standard cable with stainless steel armor and coaxial connectors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Agency approval option (Multiple hazardous area certifications including ATEX, IECEx, and CSA intrinsic safety)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-080-24-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.78 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 cm x 28.0 cm x 6.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Total Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 m (when combined with 1.0 m probe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 megohms minimum at 500 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial Composition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtruded FEP jacket over stainless steel armor braiding\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive coaxial circuit component with zero direct consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Signal Scaling and Impedance Parameters\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm proximity configuration relies on absolute match integrity across the cable assembly to preserve calibrated eddy-current probe scaling. This heavy-duty cable matches the 3300 XL 25 mm system parameter curve, allowing accurate gap voltage validation with a nominal -10 VDC target representing the measurement center. Maintaining precise physical separation from adjacent electrical conductors ensures signal cross-talk suppression. Any physical distortion or arbitrary length altering changes the baseline capacitance, causing erratic voltage feedback within the monitoring rack.\u003c\/p\u003e\n\u003ch3\u003ePackage Manifest Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330854-080-24-05 3300 XL 25 mm armored extension cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Factory-installed miniature coaxial connectors (1 male, 1 female)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation insert note containing specific hazardous area entity parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Management Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius Constraints\u003c\/strong\u003e: Maintain a structural bend radius of at least 25.4 mm (1.0 in) along the armored run to prevent inner core layer fracture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Joint Torque\u003c\/strong\u003e: Mate the clickloc coaxial connections fully by hand until a physical click occurs; do not use pliers or high-torque hand tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmor Ground Isolation\u003c\/strong\u003e: Route the stainless steel protective armor away from stray structural currents to preserve single-point ground paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Interface Sealing\u003c\/strong\u003e: Apply connector protectors or high-temperature silicone self-mating tape if connections are exposed to constant moisture or oil mist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDistribution and Transit Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShipping Frame: 2-7 days when payment finish\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogistics Courier: Shipped globally utilizing premium air freight options through DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOuter Protection: Wrapped securely within anti-static industrial packaging using shock-absorbing form-fit interior layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Queries \u0026amp; Answers\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this extension cable modify the nominal scale factor of a 25 mm sensor loop?\u003c\/p\u003e\n\u003cp\u003eNo. The cable acts as a passive transmission medium with a specific impedance profile. When matched with a 1.0 m probe, it maintains the calibrated 0.787 V\/mm scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable component be hot-swapped while the Proximitor sensor is powered?\u003c\/p\u003e\n\u003cp\u003eYes, the cable can be uncoupled while the system is energized. However, disconnecting this terminal causes an immediate open circuit, forcing the monitoring module to enter a fault state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the structural significance of the -24 option on this specific hardware model?\u003c\/p\u003e\n\u003cp\u003eThe -24 option specifies that the standard coaxial cable assembly is encased inside a continuous, flexible stainless steel armor sleeve to withstand harsh physical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does altering the 8.0 m length of this cable compromise the total safety loop?\u003c\/p\u003e\n\u003cp\u003eThe Proximitor requires a strict 9.0 m total electrical length. Shortening or lengthening the extension cable changes the tuned resonant frequency, which invalidates the calibration profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this extension cable carry any internal active power elements or micro-controllers?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive coaxial component. It carries no processing elements and relies entirely on high-frequency AC excitation current supplied from the external Proximitor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental protection does the FEP jacket provide to the internal core?\u003c\/p\u003e\n\u003cp\u003eThe Fluorinated Ethylene Propylene jacket provides chemical resistance against synthetic lubricants, oil mist, acids, and water ingress across the full operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external ground wire attachment necessary for the stainless steel armor?\u003c\/p\u003e\n\u003cp\u003eNo. The armor layer must remain isolated from intermediate structural grounds along the path. The entire assembly grounds back through the Proximitor housing ground point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the high-temperature endurance threshold for the insulation material?\u003c\/p\u003e\n\u003cp\u003eThe FEP insulation and internal silver-plated copper conductors are rated to operate continuously without dielectric breakdown from -51 deg C up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518850097325,"sku":"330854-080-24-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-080-24-05-3300-xl-25-mm-extension-cable-i5p0cd300dq.jpg?v=1766980426"},{"product_id":"330850-50-00-bently-nevada-3300-xl-25mm-proximitor-sensor","title":"330850-50-00 Bently Nevada 3300 XL 25mm Proximitor Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 330850-50-00 is a high-performance Proximitor Sensor engineered for the 3300 XL 25 mm Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis device serves as the primary signal conditioning unit,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the necessary excitation to the proximity probe and converting the returned eddy current signal into a standardized DC voltage proportional to the distance between the probe tip and the target.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed for applications requiring a large linear range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330850-50-00 is essential for monitoring structural thermal growth and large-scale displacement.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt offers a robust upgrade path for legacy 3000 and 7000 series installations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eintegrating modern RFI immunity and superior thermal stability into existing monitoring architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics and Hardware Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis 25 mm Proximitor sensor is built to deliver high-fidelity data in electrically noisy industrial environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing a compact housing that supports both high-density and traditional mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e330850-50-00\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProbe Diameter Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e25 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Length\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Meters (approx.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 feet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Signal\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-4 to -20 Vdc (Analog voltage)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSensitivity (Incremental Scale Factor)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e787 V\/mm (20 mV\/mil) or 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e94 V\/mm (100 mV\/mil) depending on specific system configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 12.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 mm (500 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Wiring\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated SpringLoc terminal strips for tool-free,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration-resistant connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e35 mm DIN-rail or panel-mount compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRFI Immunity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced shielding against high-frequency environmental interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHousing Material\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePolyphenylene sulfide (PPS) and AISI 304 Stainless Steel base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-51°C to +100°C (-60°F to +212°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330850-50-00 is a critical component of Turbine Supervisory Instrumentation (TSI),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eparticularly for assets where small-scale vibration sensors lack the necessary range to capture total movement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSteam Turbine Differential Expansion\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring the relative thermal growth between the rotor and the turbine casing during startup and shutdown cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCentrifugal Air Compressors\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding reliable axial position and radial vibration signals for high-speed industrial compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcess Gas \u0026amp; Refrigeration Equipment\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring structural health in compact or high-density machinery skids where DIN-rail mounting is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHydroelectric Generators\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTracking thrust bearing movement and rotor position in large-scale power generation units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy System Upgrades\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eReplacing obsolete 3300 RAM or 7000 series transducers to improve signal accuracy and reduce maintenance overhead.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518869463213,"sku":"330850-50-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330850-50-00-3300-xl-25-mm-proximitor-sensor-kf4wdhwofl2.jpg?v=1766980637"},{"product_id":"bently-nevada-330876-01-90-00-00-3300-xl-50-mm-proximity-probe","title":"Bently Nevada 330876-01-90-00-00 3300 XL 50 mm Proximity Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330876-01-90-00-00 3300 XL 50 mm Proximity Probe delivers highly stable non-contact vibration and displacement measurement for large rotating machinery operating in demanding industrial environments. Engineers deploy this probe across steam turbines, hydro generators, compressors, and critical process equipment where continuous shaft monitoring directly impacts operational safety and production continuity.\u003c\/p\u003e\n\u003cp\u003eIts large-diameter sensing design improves signal strength in applications involving oversized shafts and extended monitoring distances. The probe maintains accurate dynamic response under vibration, thermal fluctuation, and oil contamination conditions commonly found in power generation and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL architecture integrates seamlessly with Bently Nevada monitoring racks, TSI systems, and modern DCS platforms including Experion PKS and Ovation. The system enables fast fault detection, precise shaft position analysis, and early warning protection against mechanical failure, reducing unplanned downtime and maintenance exposure.\u003c\/p\u003e\n\u003ch2\u003eProbe Configuration Details\u003c\/h2\u003e\n\u003ch3\u003eModel Breakdown — 330876-01-90-00-00\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330876\u003c\/td\u003e\n\u003ctd\u003e3300 XL 50 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eStandard probe mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e9.0 meter system cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard agency approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard connector and packaging option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMechanical \u0026amp; Electrical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003e50 mm Eddy Current Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact Eddy Current Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e9.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eSuitable for low-frequency large shaft monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Jacket Material\u003c\/td\u003e\n\u003ctd\u003eOil-resistant Fluoroethylene Propylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePPS \/ High-temperature engineered polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eThreaded industrial mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e9031809090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Important)\u003c\/td\u003e\n\u003ctd\u003eApprox. 2.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eProbe Diameter: 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (Important)\u003c\/td\u003e\n\u003ctd\u003eApprox. 42 × 32 × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Installation Practices\u003c\/h2\u003e\n\u003cp\u003eMaintain correct target gap voltage during commissioning to ensure optimal linear measurement performance. Engineers typically verify calibrated gap conditions through the associated Proximitor output before startup.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive cable tension and maintain a minimum bending radius greater than 75 mm to preserve long-term signal stability. Route probe extension cables separately from high-voltage motor conductors to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eIn hazardous industrial zones, apply certified explosion-proof conduit practices and ensure single-point grounding architecture throughout the vibration monitoring loop.\u003c\/p\u003e\n\u003ch2\u003eOperational Performance Benefits\u003c\/h2\u003e\n\u003cp\u003eThe 3300 XL 50 mm probe operates reliably in high-moisture turbine halls, heavy vibration environments, and corrosive industrial atmospheres. Its large sensing surface improves shaft tracking consistency on slow-speed and oversized rotating assets.\u003c\/p\u003e\n\u003cp\u003eThe probe integrates directly with Bently Nevada 3500 monitoring systems and turbine supervisory instrumentation platforms without requiring additional signal conversion hardware. Operators gain faster alarm response, improved predictive maintenance visibility, and higher rotating equipment reliability across mission-critical operations.\u003c\/p\u003e\n\u003ch2\u003eOrdering Info\u003c\/h2\u003e\n\u003cp\u003e(1) Shipment includes one original Bently Nevada 330876-01-90-00-00 proximity probe\u003c\/p\u003e\n\u003cp\u003e(2) Factory-sealed anti-static industrial packaging included\u003c\/p\u003e\n\u003cp\u003e(3) Optional extension cables and Proximitor sensors available separately\u003c\/p\u003e\n\u003cp\u003e(4) Calibration verification and export documentation available upon request\u003c\/p\u003e\n\u003ch2\u003eGlobal Logistics Support\u003c\/h2\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003cp\u003eWorldwide shipment available through DHL, FedEx, and UPS international priority services. Each unit receives reinforced anti-static industrial packaging with moisture-protection treatment suitable for long-distance export transportation and heavy industrial storage conditions.\u003c\/p\u003e\n\u003ch2\u003eApplication Support FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What is the primary application of the 50 mm proximity probe?\u003cbr\u003eA1: The probe monitors shaft vibration and displacement on large rotating equipment including hydro turbines, generators, and low-speed compressors.\u003c\/p\u003e\n\u003cp\u003eQ2: What does the “90” suffix represent in this model?\u003cbr\u003eA2: The “90” configuration identifies a 9.0 meter transducer system length.\u003c\/p\u003e\n\u003cp\u003eQ3: Can this probe operate with Bently Nevada 3500 systems?\u003cbr\u003eA3: Yes. The probe fully supports compatible 3300 XL Proximitor systems connected to Bently Nevada 3500 monitoring racks.\u003c\/p\u003e\n\u003cp\u003eQ4: How should the probe cable be routed during installation?\u003cbr\u003eA4: Engineers should isolate probe cables from high-voltage power wiring and maintain proper grounding to minimize signal interference.\u003c\/p\u003e\n\u003cp\u003eQ5: What payment methods are accepted for international orders?\u003cbr\u003eA5: Most industrial procurement orders support T\/T bank transfer, PayPal, and major international commercial payment channels.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518869561517,"sku":"330876-01-90-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330876-01-90-00-00-3300-xl-50-mm-proximity-probe-4ladvbkima3.jpg?v=1766980642"},{"product_id":"330850-51-00-bently-nevada-3300-xl-nsv-proximitor-sensor-vibration-position","title":"330850-51-00 Bently Nevada 3300 XL NSv Proximitor Sensor | Vibration \u0026 Position","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 330850-51-00 is a specialized Proximitor Sensor from the 3300 XL NSv (Narrow Side-view) series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edesigned to process signals from eddy current proximity probes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis device acts as a signal conditioner,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupplying the necessary excitation to the probe and converting the returned signal into a usable voltage proportional to the distance between the probe tip and the target.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is specifically engineered for environments with space constraints where standard sensors cannot be installed,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as centrifugal air compressors and process gas equipment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 330850-51-00 provides an essential bridge for upgrading legacy systems (3300 RAM,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3000,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor 7000 series) to modern monitoring standards without requiring a complete overhaul of existing field wiring and probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Parameters and Key Characteristics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330850-51-00 is built with a focus on signal integrity and ease of installation in high-density control cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e330850-51-00\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL NSv Proximity Transducer System\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for narrow side-view applications with high linearity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRFI\/EMI Immunity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced shielding against high-frequency environmental interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWiring Interface\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSpringLoc terminal strips for tool-free,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration-resistant field connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Options\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports high-density DIN-rail mounting or traditional panel-mount layouts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Output\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog voltage output proportional to displacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConstruction\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompact,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethin-profile housing designed for limited-space enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCalibration\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFactory calibrated for AISI 4140 steel targets (Standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 3300 XL NSv system is a vital component of Turbine Supervisory Instrumentation (TSI) and machinery protection programs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts primary use cases include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCentrifugal Air Compressors\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring radial vibration and axial position where small shaft diameters or tight clearances prevent the use of standard 8mm probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLarge Steam Turbine Generators\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring differential expansion and rotor growth to prevent contact between rotating and stationary components during thermal transitions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcess Gas \u0026amp; Refrigeration Compressors\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding continuous monitoring in compact OEM machinery where high-density sensor mounting is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Modernization\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServing as a direct replacement component for aging 3000 and 7000 series transducers to improve signal stability and RFI rejection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePredictive Maintenance\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInterfacing with Bently Nevada 3500 monitoring racks to provide real-time data for trend analysis and automated alarm logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe robust design and SpringLoc terminals ensure that the 330850-51-00 remains reliable in high-vibration environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeffectively reducing maintenance intervals and preventing false trips caused by poor electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518872641709,"sku":"330850-51-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330850-51-00-proximity-sensor-x3ze0yzz2nz.jpg?v=1768892166"},{"product_id":"330850-91-00-bently-nevada-3300-xl-25-mm-proximitor-sensor","title":"330850-91-00 Bently Nevada 3300 XL 25 mm Proximitor Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330850-91-00 is a high-performance signal conditioner within the Bently Nevada 3300 XL Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to interface with 25 mm proximity probes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis Proximitor sensor converts the eddy current signal from the probe into a proportional voltage output.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis data is essential for monitoring large-scale industrial machinery where significant displacement or vibration ranges are expected.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy providing high-linearity measurements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330850-91-00 enables Turbine Supervisory Instrumentation (TSI) systems to track shaft position and vibration with laboratory-grade precision,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting condition-based maintenance and asset protection strategies.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics and Hardware Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis specific 3300 XL 25 mm Proximitor is engineered for long-term stability and ease of integration into industrial control panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Identification\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e330850-91-00\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProbe Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm Proximity Probes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Length\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Meters (approx.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e29.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 feet) (Option -91)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Option\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e35 mm DIN rail clips for high-density installation (Option -00)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Signal\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e787 V\/mm (20 mV\/mil) average scale factor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 mm (500 mils),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ebeginning at 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 mm (50 mils) from the probe tip\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFrequency Response\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 Hz (DC) to 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSupply Voltage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-17.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Vdc to -26 Vdc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Rating\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRated for operation in relative humidity up to 100% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConstruction\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRobust zinc housing with integrated coaxial connectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Benefits\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330850-91-00 Proximitor is a vital component in sectors requiring the monitoring of massive rotating assets.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts extended measurement range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprovided by the 25 mm probe system,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis particularly advantageous in scenarios where smaller 8 mm probes lack the necessary linear range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHydroelectric Power Generation\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring thermal expansion and vibration in large-diameter generator shafts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMining and Metal Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTracking displacement in heavy-duty crushers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emills,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand conveyor drive systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRenewable Energy\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eImplementing speed detection and structural vibration monitoring in large-scale wind turbine assemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSteam and Gas Turbines\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding axial thrust position data where large rotor movements are anticipated during thermal transients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndustrial Speed Control\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServing as a high-resolution input for electronic overspeed protection systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe DIN-rail mounting configuration (Option -00) facilitates rapid deployment in standard industrial enclosures,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhile the 9.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter system length allows for flexible placement of the sensor relative to the machine casing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprotecting the electronics from the most extreme local heat and vibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518884176045,"sku":"330850-91-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330850-91-00-3300-xl-25-mm-proximitor-sensor-ingtjqundvv.jpg?v=1766981002"},{"product_id":"bently-nevada-330851-02-000-60-10-00-05-proximity-probe-3300-xl-series","title":"Bently Nevada 330851-02-000-60-10-00-05 Proximity Probe 3300 XL Series","description":"\u003cp\u003eConfigured for high-range displacement and position measurement in industrial rotating equipment, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-02-000-60-10-00-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical execution of eddy-current signal transduction within 3300 XL transducer systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe part number 330851-02-000-60-10-00-05 defines the following transducer configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330851: 25 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Total Length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e000: Unthreaded Length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e60: Overall Case Length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Connector Option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency Approval\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Country Specific Options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-000-60-10-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 x 25 x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowered via 3300 XL Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm probe system utilizes eddy-current probe scaling specifically tuned for large-gap measurements. Accurate signal transduction requires gap voltage validation against the -10 VDC target range to ensure rotor dynamics data remains within linear limits. Cross-talk suppression is a mandatory consideration during installation; the probe's electromagnetic field density necessitates maintaining strict spatial separation from adjacent transducers to prevent signal coupling and harmonic distortion.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330851 25 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective connector cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical installation data and compliance documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the probe into the machinery casing using the primary locknut. Ensure the probe tip is perpendicular to the target shaft surface to avoid geometric measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Adjustment\u003c\/strong\u003e: Calibrate the initial air gap using a high-impedance digital voltmeter at the Proximitor sensor output, ensuring the value aligns with the machinery's specific dynamic clearance requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Route the coaxial cable through shielded conduit and terminate the shield to the common ground at the monitor rack to mitigate EMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Keep signal paths clear of AC power cables to eliminate induced noise in the low-voltage transducer circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogistics and Transit\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComponents are sealed in anti-static industrial packaging to prevent electrostatic discharge and mechanical impact during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat material targets are supported?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory calibration is set for AISI 4140 steel; alternative target materials require custom calibration curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the probe sensitivity?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe nominal sensitivity for this system is 3.94 V\/mm (100 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should calibration be verified?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCalibration verification is required during major machine overhauls or if signal drift is detected via the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the probe operate in hazardous environments?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, provided the system is installed in adherence to approved hazardous area certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat extension cables are compatible?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnly 3300 XL series coaxial extension cables are designed to match the system impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable gap voltage?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnstable voltage is typically caused by cable damage, loose mechanical supports, or electromagnetic noise on the signal loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is probe health tested?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHealth is verified through coaxial continuity checks and ensuring the DC gap voltage remains stable within the designated linear operating window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected service life?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eService life depends on the thermal environment and the level of mechanical vibration at the installation point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518884241581,"sku":"330851-02-000-60-10-00-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-02-000-60-10-00-05-3300-xl-25-mm-proximity-probe-yushri0oba0.jpg?v=1766981004"},{"product_id":"bently-nevada-330851-02-000-080-10-00-00-proximity-probe","title":"Bently Nevada 330851-02-000-080-10-00-00 Proximity Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330851-02-000-080-10-00-00 is a high-performance 3300 XL NSv (Near-field) Proximity Transducer system, specifically designed for mission-critical vibration monitoring of small-diameter shafts. When rotating machinery reaches high operational speeds, conventional 8mm sensors often fail to provide the necessary linear range or resolution. This NSv transducer fills that gap, offering engineers precise measurement capabilities for small-scale components that traditional sensors simply cannot handle.\u003c\/p\u003e\n\u003cp\u003eWhether you are looking to Buy 330851-02-000-080-10-00-00 for a new installation or a critical replacement, you are selecting a sensor that adheres to the highest industry benchmarks, including API 670 compliance. As a dedicated Industrial Automation Spare Parts supplier, Maxwell PLC maintains these components In Stock, ensuring that your facility minimizes downtime. By integrating this Genuine Bently Nevada Parts solution into your monitoring architecture, you gain a robust defense against unpredictable equipment failures.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall-Target Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for shafts smaller than 15 mm, ensuring excellent linear output where other sensors lack sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Near-Field Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NSv technology delivers superior signal resolution at close proximities, essential for detecting micro-vibrations in compact machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully tested to meet American Petroleum Institute (API) 670 standards, guaranteeing reliability in high-stakes environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResilient Build:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConstructed with an AISI 303 stainless steel housing and Polyphenylene Sulfide (PPS) tip for thermal and chemical durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures the high-reliability ClickLoc miniature coaxial connector, preventing signal drops caused by mechanical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-000-080-10-00-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL NSv (Near-field)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF-2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal System Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 meters (80 cm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 * 12.0 * 8.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eModel Configuration Explanation\u003c\/h2\u003e\n\u003cp\u003eThe 330851-02-000-080-10-00-00 part number follows Bently Nevada’s rigid engineering code:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330851:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNSv Proximity Probe model identifier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProbe tip and case material designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e000:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnthreaded case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e080:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTotal system cable length (0.8 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnector type and configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00-00:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApproval rating and agency classification options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eThe NSv transducer is the primary choice for specialized rotating equipment:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Small Turbines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring radial vibration and axial position on compact turbo-expanders.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentrifugal Compressors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for staging rotors with small-diameter shaft areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision CNC Spindles:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking displacement in high-speed, precision manufacturing equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResearch and Development:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed for experimental measurement on small-scale rotating prototypes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cp\u003eThis sensor is engineered to integrate perfectly with the Bently Nevada 3300 XL NSv Proximitor. It is a critical data point for the 3500\/42M Proximitor Monitoring System. When you obtain this model from a reliable 330851-02-000-080-10-00-00 Supplier, you ensure that the entire monitoring chain—from probe to signal processor—maintains the factory-calibrated impedance required for 200 mV\/mil accuracy.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClean the mounting surface and probe holder to remove any contaminants that could interfere with signal linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Setting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsing a precision gap-setting tool, position the probe tip at the manufacturer-recommended air gap (typically 1.0 mm range center).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the mounting jam nuts to the specified torque to prevent loosening during high-frequency machine operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the coaxial cable inside metallic conduit, avoiding proximity to high-current wiring to mitigate electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaseline Validation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePost-installation, perform a DC gap voltage check to confirm the sensor is within its active linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eProduct Advantages\u003c\/h2\u003e\n\u003cp\u003eInvesting in this genuine Bently Nevada sensor provides long-term operational stability. Compared to generic sensors, the 330851-02-000-080-10-00-00 offers:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStable signal output even when the machine warms up or cools down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRFI\/EMI Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced internal shielding prevents the environmental noise commonly found in motor rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReduced False Trips:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures your safety system reacts to real machine issues rather than sensor inaccuracies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003eWe offer competitive 330851-02-000-080-10-00-00 Price structures for both single unit orders and bulk procurement. As a leading Industrial Automation Spare Parts supplier, we provide full support, from technical validation of your part number to expedited global shipping logistics.\u003c\/p\u003e\n\u003ch2\u003eLogistics and Shipping\u003c\/h2\u003e\n\u003cp\u003eWe prioritize the integrity of your hardware. All sensors are shipped using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e, providing a robust barrier against electrostatic discharge (ESD) and physical impact. We coordinate with elite courier services to ensure your Genuine Bently Nevada Parts arrive in perfect factory condition, ready for installation.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose Maxwell PLC\u003c\/h2\u003e\n\u003cp\u003eMaxwell PLC has served the industrial sector for decades. We combine technical expertise with a commitment to reliability. By choosing us as your 330851-02-000-080-10-00-00 Supplier, you receive:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuthenticity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGuaranteed factory-original hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Logistics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFast shipping to any industrial location.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpertise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOur team provides answers to complex technical and procurement queries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhy do I need an NSv probe instead of a standard 8mm probe?\u003c\/p\u003e\n\u003cp\u003eNSv probes are designed for shafts under 15mm; a standard 8mm probe would be too large to measure accurately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330851-02-000-080-10-00-00 in stock?\u003c\/p\u003e\n\u003cp\u003eYes, we maintain a large inventory of NSv components for immediate shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes it include the required nuts?\u003c\/p\u003e\n\u003cp\u003eYes, the probe includes the essential jam nuts for secure installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with my 3300 monitoring rack?\u003c\/p\u003e\n\u003cp\u003eYes, it is designed for all 3300 and 3500 series monitoring systems using NSv Proximitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo you provide calibration certificates?\u003c\/p\u003e\n\u003cp\u003eYes, all Genuine Bently Nevada Parts come with factory quality validation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre these units refurbished?\u003c\/p\u003e\n\u003cp\u003eNo, all our products are 100% new, genuine factory-sealed industrial spare parts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I order using a corporate purchase order?\u003c\/p\u003e\n\u003cp\u003eYes, we work closely with procurement departments to facilitate formal purchase orders.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow long does shipping usually take?\u003c\/p\u003e\n\u003cp\u003eWe prioritize fast processing, with most domestic orders arriving within days and international orders managed by reliable couriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat if the probe signal is noisy?\u003c\/p\u003e\n\u003cp\u003eTypically, this is caused by improper grounding or cable interference. Ensure your cables are shielded properly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan you assist with part cross-referencing?\u003c\/p\u003e\n\u003cp\u003eOur technical experts are available to help you verify that this part fits your specific machine configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Models\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330909-00-25-10-02-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330103-00-12-10-02-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330101-00-72-20-02-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 89477-10 (Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518885617837,"sku":"330851-02-000-080-10-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-02-000-080-10-00-00-proximity-probe-todqccgs0qt.jpg?v=1766981056"},{"product_id":"330854-040-24-00-bently-nevada-extension-cables-3300-xl","title":"330854-040-24-00 Bently Nevada Extension Cables 3300 XL","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330854-040-24-00 is a high-performance extension cable designed to bridge the gap between Bently Nevada proximity probes and their corresponding Proximitor sensors. As an integral component of the 3300 XL series vibration monitoring system, this cable ensures the precise transmission of dynamic shaft signals in critical rotating machinery. In industrial environments where signal integrity determines the safety and longevity of assets like turbines, compressors, and pumps, using genuine factory cables is not an option—it is a requirement.\u003c\/p\u003e\n\u003cp\u003eFor maintenance engineers and procurement officers, selecting the right cable is essential to avoiding signal noise and impedance mismatches. The 330854-040-24-00 is engineered for extreme durability, resisting the harsh chemicals, heat, and mechanical stress typical of oil, gas, and power generation facilities. Maxwell PLC maintains these genuine Bently Nevada parts in stock, providing an immediate procurement solution for your maintenance and emergency repair needs.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to minimize EMI\/RFI interference, ensuring clear, accurate signal data from the probe to the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePerfectly matched to Bently Nevada 3300 XL system architectures for consistent 200 mV\/mil output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Jacket Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt with specialized high-temperature, oil-resistant materials for superior longevity in challenging industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with industry-standard ClickLoc connectors, ensuring rapid installation and high resistance to vibration-induced loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Compliant:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets international standards for machinery protection, ensuring your system maintains audit-ready reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-040-24-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 Meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc Miniature Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJacket Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Grade Fluoropolymer \/ Industrial Rubber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 * 20.0 * 8.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eModel Configuration Explanation\u003c\/h2\u003e\n\u003cp\u003eThe 330854-040-24-00 part number follows the specific Bently Nevada logistics and technical coding:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330854:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepresents the 3300 XL series extension cable line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e040:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDenotes the specific cable length of 4.0 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e24:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the connector configuration and cable protection option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepresents the agency approval rating (standard classification).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eThese extension cables are critical in various high-speed rotation applications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSteam and Gas Turbines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVital for linking radial vibration probes to monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentrifugal Compressors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring accurate rotor position tracking in gas processing units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge Industrial Motors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring bearing stability in high-torque environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePumps and Fans:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding essential diagnostic data for preventative maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe 330854-040-24-00 is specifically calibrated for the Bently Nevada 3300 XL 8mm and 5mm Proximity Transducer Systems. It connects seamlessly to the Bently Nevada 3500\/42M Proximitor Monitor. When you buy 330854-040-24-00 from us, you are guaranteed perfect hardware integration, eliminating the risks of signal degradation often found with aftermarket \"compatible\" cabling.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways route cables through dedicated metallic conduits to prevent physical crushing and reduce EMI exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBending Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eObserve the manufacturer's recommended minimum bend radius; sharp kinks can damage the internal coaxial structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the ClickLoc mechanism to ensure the connector is fully seated. Do not force connections; if resistance is felt, check for debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain isolation where required by the system design to prevent ground loops between the probe and the monitor rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTesting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePerform a baseline check of the DC gap voltage at the monitor terminal block post-installation to verify system health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eProduct Advantages\u003c\/h2\u003e\n\u003cp\u003eInvesting in genuine Bently Nevada parts like the 330854-040-24-00 is a direct investment in the reliability of your turbomachinery. Genuine parts offer superior shielding, precise impedance characteristics, and reliable performance across the specified temperature range. As a preferred Industrial Automation Spare Parts supplier, we emphasize that original factory-certified cabling prevents false trips that can cost your facility tens of thousands of dollars in lost production.\u003c\/p\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003eTo receive a formal 330854-040-24-00 price quote or to check bulk availability, please contact our sales team. We offer tailored logistics solutions for global projects. If you need this component in stock for a scheduled shutdown or an immediate repair, our team is equipped to assist you.\u003c\/p\u003e\n\u003ch2\u003eLogistics and Shipping\u003c\/h2\u003e\n\u003cp\u003eWe understand that industrial downtime is unacceptable. Every 330854-040-24-00 is shipped in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e. This professional-grade packaging ensures your cables are protected against electrostatic discharge (ESD) and mechanical impacts during international shipping. We partner with reputable carriers to ensure fast, tracked delivery to your site.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose Maxwell PLC\u003c\/h2\u003e\n\u003cp\u003eMaxwell PLC is a trusted global provider of Industrial Automation Spare Parts. We bring 50 years of collective technical expertise to your procurement process. We do not just process orders; we ensure you get the exact hardware required for your specific monitoring system architecture. Our commitment to quality, genuine products, and rapid response times makes us the leading 330854-040-24-00 supplier.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330854-040-24-00 in stock?\u003c\/p\u003e\n\u003cp\u003eYes, we maintain a robust inventory of 3300 XL series cables for immediate global dispatch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use a 4.0-meter cable to replace a 3.0-meter cable?\u003c\/p\u003e\n\u003cp\u003eNo. Bently Nevada systems are calibrated for specific lengths. Replacing with a different length will alter the signal impedance and calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable oil-resistant?\u003c\/p\u003e\n\u003cp\u003eYes, the outer jacket is designed to handle common industrial fluids and chemicals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo you sell refurbished cables?\u003c\/p\u003e\n\u003cp\u003eNo, Maxwell PLC only supplies 100% brand-new, genuine Bently Nevada parts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow long is the warranty?\u003c\/p\u003e\n\u003cp\u003eThe product carries the standard manufacturer's warranty for new industrial parts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo you offer volume discounts?\u003c\/p\u003e\n\u003cp\u003eYes, we provide tiered pricing for plant-wide turnarounds and large-scale projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre connectors included with the cable?\u003c\/p\u003e\n\u003cp\u003eYes, the 330854 series comes fully assembled with the factory-certified ClickLoc connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat if I need a different length?\u003c\/p\u003e\n\u003cp\u003eOur catalog includes various cable lengths (e.g., 5.0m, 9.0m). Contact our sales team to verify your required length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I request a certificate of conformity?\u003c\/p\u003e\n\u003cp\u003eYes, we provide full factory documentation upon request for all genuine parts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow fast can you ship?\u003c\/p\u003e\n\u003cp\u003eMost in-stock orders are processed and ready for courier pickup within 24 to 48 hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Models\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330854-030-24-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330854-050-24-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330103-00-12-10-02-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330101-00-72-20-02-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518885716141,"sku":"330854-040-24-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-040-24-00-extension-cable-vpqhn3r5lmk.jpg?v=1766981062"},{"product_id":"bently-nevada-330854-080-25-05-3300-xl-25mm-extension-cable","title":"Bently Nevada 330854-080-25-05 3300 XL 25mm Extension Cable","description":"\u003ch2\u003eHigh-Fidelity Signal Integrity\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 330854-080-25-05 extension cable serves as the critical high-impedance link within the 3300 XL 25mm Proximity Transducer System. Specifically designed for large-scale rotating machinery, this cable maintains the electrical length required to ensure precise displacement and axial position data transmission between the 25mm probe and the Proximitor sensor. In heavy-duty environments like steam turbine halls or large pumping stations, this cable acts as a shielded conduit, protecting weak eddy-current signals from electromagnetic interference (EMI) and mechanical stress. By utilizing low-loss coaxial architecture and ruggedized armor, it ensures the Bently Nevada 3500 system receives the accurate, real-time data necessary for mission-critical emergency shutdown (ESD) decisions.\u003c\/p\u003e\n\u003ch2\u003eSuffix Configuration and Material Analysis\u003c\/h2\u003e\n\u003ch3\u003e330854 - 3300 XL 25mm Extension Cable\u003c\/h3\u003e\n\u003cp\u003eIdentifies the specialized extension cable compatible only with the 3300 XL 25mm proximity probe series, featuring specific capacitance matching for extended range measurements.\u003c\/p\u003e\n\u003ch3\u003e080 - Cable Length\u003c\/h3\u003e\n\u003cp\u003eDesignates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8.0-meter (26.2 feet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable length. When combined with a 1.0-meter probe, this configuration completes a standard 9.0-meter electrical system, ensuring the Proximitor remains calibrated to the sensor.\u003c\/p\u003e\n\u003ch3\u003e25 - Armor and Cable Option\u003c\/h3\u003e\n\u003cp\u003eSpecifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStainless Steel Armor with FEP Jacket\u003c\/strong\u003e. The interlocking stainless steel armor provides superior crush resistance and protection against sharp metal debris, while the Fluorinated Ethylene Propylene (FEP) jacket offers exceptional chemical and moisture resistance.\u003c\/p\u003e\n\u003ch3\u003e05 - Agency Approval Option\u003c\/h3\u003e\n\u003cp\u003eConfirms multiple global hazardous area certifications, including ATEX, IECEx, and North American CSA standards. This allows for safe installation in volatile industrial zones when paired with intrinsically safe barriers.\u003c\/p\u003e\n\u003ch2\u003eMechanical and Electrical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-080-25-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85442000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1.15 kg (2.54 lbs)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8.0 Meters (26.2 ft)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3.94 mm (0.155 in) without armor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmored Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8.89 mm (0.350 in)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +177°C (-60°F to +351°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Engineering and Routing Guide\u003c\/h2\u003e\n\u003cp\u003eProper cable management is vital to preventing signal attenuation and \"Not OK\" faults. Engineers must ensure the miniature coaxial connectors are clean and dry before mating; use a dedicated connector protector or heat-shrink tubing to prevent oil ingress in the junction box. When routing the armored cable, respect the 25.4 mm (1.0 inch) minimum bend radius to avoid internal conductor fatigue. Ensure the armor is grounded only at the system monitor end to prevent ground loops. In hazardous area deployments, verify that the cable is secured within conduit or tray systems according to local explosion-proof wiring codes.\u003c\/p\u003e\n\u003ch2\u003eResilience in Extreme Environments\u003c\/h2\u003e\n\u003cp\u003eThe 330854-080-25-05 is built for the harshest corners of the plant floor. The FEP insulation maintains its dielectric properties under extreme thermal cycling—from cryogenic lows to the blistering heat near turbine casings. Its stainless steel armor prevents accidental severing during maintenance activities, while the shielded coaxial core rejects noise from nearby variable frequency drives (VFDs) and high-voltage motor leads. This cable integrates seamlessly with the Bently Nevada 3500\/42M or 3500\/45 modules, providing a stable backbone for Turbine Supervisory Instrumentation (TSI) and integration into Honeywell Experion PKS or Emerson DeltaV platforms.\u003c\/p\u003e\n\u003ch2\u003eLogistics and Dispatch Standards\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish, BY DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003cp\u003eWe deliver all extension cables in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static industrial packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the connectors capped to prevent oxidation and contamination during global transit.\u003c\/p\u003e\n\u003ch2\u003eTechnical Support FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 8.0m cable with an 8mm or 11mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 330854 is electrically matched specifically for the 25mm system. Using it with 8mm or 11mm probes will cause significant linearity errors and scale factor inaccuracies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the total system length when using this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: This 8.0m cable is designed to be used with a 1.0m probe, creating a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter total system\u003c\/strong\u003e. Ensure your 3300 XL Proximitor is also configured for a 9.0m system length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I identify if the extension cable is faulty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Use a Bently Nevada TK-3 or a voltmeter to check the bias voltage. A sudden shift to the positive or negative supply rail often indicates a broken center conductor or a short to the armor within the extension cable.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518912651437,"sku":"330854-080-25-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-080-25-05-extension-cable-qaurovk0jwe.jpg?v=1766981466"},{"product_id":"330851-02-000-060-10-01-05-bently-nevada-3300-xl-series-proximity-probe","title":"330851-02-000-060-10-01-05 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for high-temperature differential expansion and shaft position surveillance within steam turbine platforms, the \u003cstrong\u003eBently Nevada 330851-02-000-060-10-01-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330851\u003c\/strong\u003e 3300 XL 25 mm Proximity Probe, operates as a dedicated hardware component for eddy-current displacement measurement across machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Number: 330851 (3300 XL 25 mm Proximity Probe Assembly)\u003c\/li\u003e\n\u003cli\u003eProbe Case Type Option (-02): M30x2 thread configuration with 0 mm unthreaded length\u003c\/li\u003e\n\u003cli\u003eOverall Case Length Option (-000): 0.6 in case length parameter\u003c\/li\u003e\n\u003cli\u003eTotal Length Option (-10): 1.0 metre (3.3 feet) cable length\u003c\/li\u003e\n\u003cli\u003eArmor and Approval Options (-01-05): Includes stainless steel armor and multiple hazardous area approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-060-10-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.8 x 2.8 x 115 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUp to 200 deg C continuous (250 deg C intermittent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via monitor rack supplying -17.5 VDC to -26 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n\u003ctd\u003e12.7 mm (500 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Transducer Measurement Mechanics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEddy-Current Probe Scaling: The 25 mm transducer utilizes high-frequency radio frequency circuitry to excite the probe tip coil, producing a linear voltage output proportional to the wide gap distance between the probe face and large turbine shaft targets.\u003c\/li\u003e\n\u003cli\u003eGap Voltage Validation: Field technicians must verify that the initial static operating point achieves exact voltage parameters using a calibrated multimeter during mechanical alignment to ensure linear response across the extended dynamic range.\u003c\/li\u003e\n\u003cli\u003eCross-Talk Suppression: Spatial isolation and high-frequency modulation design prevent electromagnetic interference when multiple large-format proximity probes are installed adjacently on complex turbine casings.\u003c\/li\u003e\n\u003cli\u003eRotor Dynamics Monitoring: Translates large-scale thermal growth, differential expansion, and axial rotor movement into high-fidelity electrical inputs for continuous machinery protection monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330851-02-000-060-10-01-05 330851 Proximity Probe Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Matching 3300 XL 25 mm Extension Cable with SST Armor\u003c\/li\u003e\n\u003cli\u003e1 x Connector Protector and Installation Tool Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTarget Material Verification: Ensure the monitored target consists of flat AISI 4140 steel with a minimum diameter of 61 mm (2.4 in) to maintain linear scaling accuracy.\u003c\/li\u003e\n\u003cli\u003eSliding Bracket Usage: Utilize a dedicated sliding bracket during commissioning to physically move the probe, simulating shaft motion and verifying system calibration.\u003c\/li\u003e\n\u003cli\u003eLocknut Torque and Safety Wire: Tighten the M30x2 threaded case locknut securely, utilizing pre-drilled safety wire holes to prevent loosening under severe turbine vibration.\u003c\/li\u003e\n\u003cli\u003eMoisture Protection Routing: Route the FluidLoc cable carefully through tight clearances using the removable ClickLoc connector collar while maintaining front and rear seal integrity against steam environment moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total nominal weight of the 330851 probe assembly?\u003c\/p\u003e\n\u003cp\u003eThe unit weighs approximately 0.34 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical shipping package dimensions?\u003c\/p\u003e\n\u003cp\u003eThe shipping container measures 2.8 x 2.8 x 115 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat linear measurement range does the 25 mm transducer provide?\u003c\/p\u003e\n\u003cp\u003eIt delivers an extended linear measurement range of 12.7 mm (500 mils).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal scale factor for this 25 mm probe system?\u003c\/p\u003e\n\u003cp\u003eThe incremental scale factor is calibrated to 0.787 V\/mm, equivalent to 20 mV\/mil.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum operating temperature can the probe withstand continuously?\u003c\/p\u003e\n\u003cp\u003eThe probe is rated for continuous operation in temperatures up to 200 deg C (392 deg F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat intermittent temperature limit is supported by the sensor tip?\u003c\/p\u003e\n\u003cp\u003eIt can withstand intermittent high temperatures up to 250 deg C (482 deg F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat primary machinery parameter does this transducer monitor?\u003c\/p\u003e\n\u003cp\u003eIt monitors differential expansion (DE) on mid-size to large steam turbine generators caused by differential thermal growth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shaft target dimensions are required for optimal accuracy?\u003c\/p\u003e\n\u003cp\u003eThe system requires a flat AISI 4140 steel target with a minimum diameter of 61 mm (2.4 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025260826797,"sku":"330851-02-000-060-10-01-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-55_36b3a598-1c5a-47a6-9444-a53b45c330ca.jpg?v=1783667380"},{"product_id":"330854-080-24-00-bently-nevada-3300-system-high-temperature-fluidloc-cable-extension-cables","title":"330854-080-24-00 Bently Nevada 3300 System High Temperature FluidLoc Cable Extension Cables","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330854-080-24-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330854-080-24-00\u003c\/strong\u003e High Temperature FluidLoc Cable, operates as a dedicated hardware component for signal transmission extension and fluid-ingress prevention tasks within 3300 system eddy-current transducer circuits.\u003c\/p\u003e\n\u003ch3\u003eDesignation Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase model code: 330854 designating the high-temperature FluidLoc extension cable variant for 3300 transducer systems.\u003c\/li\u003e\n\u003cli\u003eLength option: 080 indicating the specific cable length configuration designed for extended distance routing.\u003c\/li\u003e\n\u003cli\u003eConnector option: 24 indicating specialized connector protection or termination styles.\u003c\/li\u003e\n\u003cli\u003eAdditional option: 00 specifying standard factory assembly configurations without extra special requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330854-080-24-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 x 15.0 x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive analog signal transmission line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial transmission standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Signal Transmission Integrity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplements precise eddy-current probe scaling compatibility to maintain linear millivolt-per-unit output ratios across extended line lengths.\u003c\/li\u003e\n\u003cli\u003ePreserves gap voltage validation baselines by preventing signal attenuation or ground loop introduction between probe tips and monitor racks.\u003c\/li\u003e\n\u003cli\u003eMaintains high-frequency response characteristics required for capturing transient rotor dynamics and synchronous vibration waveforms.\u003c\/li\u003e\n\u003cli\u003eUtilizes specialized FluidLoc construction to prevent moisture and fluid migration through the cable core, ensuring cross-talk suppression in harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330854-080-24-00 High Temperature FluidLoc Cable unit\u003c\/li\u003e\n\u003cli\u003e1 x Protective connector cap set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation and Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the coaxial extension cable through designated metal conduits to protect the outer jacket from mechanical abrasion and high radiant heat.\u003c\/li\u003e\n\u003cli\u003eEnsure all coaxial screw connectors are torqued finger-tight plus an additional incremental turn using a calibrated wrench to prevent signal degradation.\u003c\/li\u003e\n\u003cli\u003eMaintain complete electrical isolation between the coaxial shield and external machine casing grounds except at the designated monitor termination point.\u003c\/li\u003e\n\u003cli\u003eVerify system loop resistance and check static gap voltages prior to machinery startup to confirm signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary application of the 330854-080-24-00 cable?\u003c\/p\u003e\n\u003cp\u003eA: It functions as an extension cable linking proximity probes to monitor racks in high-temperature environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the characteristic impedance of this coaxial transmission line?\u003c\/p\u003e\n\u003cp\u003eA: The cable is engineered to maintain a strict 75 ohm coaxial impedance standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What does the FluidLoc designation signify in this hardware build?\u003c\/p\u003e\n\u003cp\u003eA: It indicates a specialized internal barrier design that stops fluid and oil migration through the cable strands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum operating temperature limit for this component?\u003c\/p\u003e\n\u003cp\u003eA: The cable is rated to withstand continuous operational temperatures up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this extension cable affect the overall scale factor of the transducer system?\u003c\/p\u003e\n\u003cp\u003eA: Matching the exact electrical length ensures the nominal scale factor remains unaffected during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are special tools required to couple the connectors?\u003c\/p\u003e\n\u003cp\u003eA: Standard coaxial connectors should be secured carefully to avoid damaging the inner pins or stripping threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the cable handle electromagnetic interference?\u003c\/p\u003e\n\u003cp\u003eA: The shielded coaxial construction combined with proper grounding suppresses external electrical noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the total approximate weight of the packaged item?\u003c\/p\u003e\n\u003cp\u003eA: The packaged unit features an approximate physical weight of 0.35 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026442670253,"sku":"330854-080-24-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian12_48597d85-245a-4877-adea-a82bc08a59e4.jpg?v=1783667097"},{"product_id":"330851-02-000-066-10-00-00-bently-nevada-3300-xl-proximity-probe","title":"330851-02-000-066-10-00-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting displacement sensing tasks in turbomachinery train monitoring loops, the \u003cstrong\u003eBently Nevada 330851-02-000-066-10-00-00\u003c\/strong\u003e (\u003cstrong\u003e330851-02-000-066-10-00-00\u003c\/strong\u003e Proximity Probe) provides direct physical\/electrical execution of eddy-current gap variations.\u003c\/p\u003e\n\u003ch3\u003eOption Structure \u0026amp; Code Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330851\u003c\/strong\u003e: Core designator for the 3300 XL 25 mm proximity probe hardware configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Specifies an M30x2 threaded case geometric outline.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000\u003c\/strong\u003e: Indicates a 0.0 in unthreaded length variable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e066\u003c\/strong\u003e: Denotes a 0.6 in total overall case length parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: Sets the physical electrical cable length to exactly 1.0 metre (3.3 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Confirms a fluid-tight plain cable structure with no external armor cladding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Restricts safety categorization options to standard no approvals configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Dimensions\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-066-10-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.5 x 22.5 x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C nominal sensor range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer element powered by external Proximitor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Profile\u003c\/td\u003e\n\u003ctd\u003eM30x2 threads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e0.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Total Length\u003c\/td\u003e\n\u003ctd\u003e1.0 metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Scaling \u0026amp; Rotor Dynamics Validation\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm coil assembly relies on precise eddy-current probe scaling matrices to accurately translate physical gap voltage changes into micro-inch metrics. During high-amplitude rotor dynamics excursions, the continuous linear response slope feeds directly into proximity sensor channels to ensure valid tracking without cross-talk suppression failures near local journal bearing housings.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330851-02-000-066-10-00-00 3300 XL 25 mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Coaxial Connector Protection Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting \u0026amp; Mechanical Alignment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBracket Torque \u0026amp; Thread Indexing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eThread the M30 case systematically into the target mounting bracket using standard mechanical steps.\u003c\/li\u003e\n\u003cli\u003eAvoid tight twisting profiles on the output coaxial pig-tail line while adjusting the insertion position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Cable Routing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the 1.0 metre signal extension line inside matching metallic conduit runs to prevent mechanical chafing.\u003c\/li\u003e\n\u003cli\u003eKeep minimum bend radii parameters above 25.4 mm (1.0 in) along all physical junction paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer Infrastructure FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the target gap voltage indication value during a standard static calibration loop?\u003c\/p\u003e\n\u003cp\u003eThe industrial benchmark targets a standard nominal -10 VDC gap voltage level at the geometric center of the linear calibration span.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this specific unarmored coaxial cable variant be deployed inside fluid-splash areas?\u003c\/p\u003e\n\u003cp\u003eYes, the outer polymer jacket resists standard synthetic machine lubricating oils, but open physical crushing forces must be avoided.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the internal field terminal links protected from shorting against surrounding metal machinery frames?\u003c\/p\u003e\n\u003cp\u003eThe probe connector terminal must be fully insulated using the enclosed clear sleeve kits to isolate the outer signal shield loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat behavior occurs if the target rotor moves completely past the physical calibration range?\u003c\/p\u003e\n\u003cp\u003eThe output electrical link saturates toward upper limit voltages, which triggers a transducer limit flag inside the tracking monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this 25 mm transducer system share identical extension cables with smaller 8 mm probe setups?\u003c\/p\u003e\n\u003cp\u003eNo, the 25 mm transducer structure uses dedicated matching networks that cannot be paired with 8 mm component configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mechanical thread engagement step is needed to lock the case into a blind machine port safely?\u003c\/p\u003e\n\u003cp\u003eThe mounting sequence requires a minimum of 5 full thread engagements to ensure structural stability against continuous mechanical vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs a separate calibration adjustment needed if the target shaft alloy changes from 4140 steel?\u003c\/p\u003e\n\u003cp\u003eYes, changes in target chemistry modify the eddy-current probe scaling performance, requiring customized instrument adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum continuous storage temperature limit allowed for this unpowered hardware?\u003c\/p\u003e\n\u003cp\u003eThe passive hardware elements maintain physical layout stability across storage ranges from -51 to +177 deg C without damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026686496941,"sku":"330851-02-000-066-10-00-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--4_827c014a-ffa5-45f0-a576-486efdfe0943.jpg?v=1783666025"},{"product_id":"330851-02-000-060-50-00-05-bently-nevada-proximity-probes-3300-xl-series","title":"330851-02-000-060-50-00-05 Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330851-02-000-060-50-00-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330851\u003c\/strong\u003e Proximity Probes, operates as a dedicated hardware component for non-contacting displacement measurement within \u003cstrong\u003e3300 XL\u003c\/strong\u003e platforms. Configured as a large-scale 25 mm sensor tip system, the hardware tracks physical gap variations between the probe face and rotating machine targets by generating high-frequency eddy-current field modulations.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330851: Base model designator for the 3300 XL 25 mm proximity probe assembly.\u003c\/li\u003e\n\u003cli\u003e02: Case thread configuration specifying an M30 x 2 metric threaded body.\u003c\/li\u003e\n\u003cli\u003e000: Minimum unthreaded length code mapping to 0 mm of smooth cylindrical sleeve.\u003c\/li\u003e\n\u003cli\u003e060: Minimum threaded length configuration defining a 60 mm fully threaded section.\u003c\/li\u003e\n\u003cli\u003e50: Total system length option selecting a 5.0 meter (16.4 feet) integrated cable.\u003c\/li\u003e\n\u003cli\u003e00: Armor configuration selecting a standard layout without flexible metal armor.\u003c\/li\u003e\n\u003cli\u003e05: Agency approval variant selecting the international multiple approvals matrix.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330851-02-000-060-50-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Thread Geometry\u003c\/td\u003e\n\u003ctd\u003eM30 x 2 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThreaded Length\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Span\u003c\/td\u003e\n\u003ctd\u003e5.0 meter (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Option\u003c\/td\u003e\n\u003ctd\u003eNo Armor, standard insulation sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive inductive probe driven by active RF signal from host Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.5 cm x 22.5 cm x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm sensor diameter extends the linear measurement envelope to track larger dynamic displacement fields. Continuous monitoring depends on precise eddy-current probe scaling constants, converting broad mechanical shaft motion into proportional voltage transitions. The system configuration records fluid-film changes and low-frequency rotor dynamics states, while structural shielding across the 5.0 meter loop maintains target cross-talk suppression safety factors when running near large industrial machinery structures.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330851-02-000-060-50-00-05 Proximity Probe Unit\u003c\/li\u003e\n\u003cli\u003e1 x Coaxial Connector Interface Insulator Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Seating and Probe Positioning\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThread the M30 x 2 case structure into the pre-drilled brackets, checking for clean mechanical thread engagement across the full 60 mm line.\u003c\/li\u003e\n\u003cli\u003eAdjust insertion depth to align the physical sensor gap with the mid-scale operational voltage point before tightening the primary anchoring hex nuts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCable Routing and External Shielding\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRun the unarmored 5.0 meter cable through protective conduits, maintaining minimum bend radii to protect the internal coaxial components.\u003c\/li\u003e\n\u003cli\u003eTerminate the outer braid shield element strictly at the host instrumentation monitor rack common terminal block to prevent destructive ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swap disconnection of the coaxial terminal permitted while the monitoring system is live?\u003c\/p\u003e\n\u003cp\u003eYes, the loop configuration allows hot-swap sensor replacement or maintenance without causing terminal damage or monitor channel faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 25 mm tip diameter affect standard eddy-current probe scaling parameters?\u003c\/p\u003e\n\u003cp\u003eThe large tip geometry widens the electromagnetic field distribution, expanding the linear window but reducing the millivolt-per-mil response factor compared to smaller 8 mm tips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat problem occurs if the field installation alters the calibrated 5.0 meter cable loop length?\u003c\/p\u003e\n\u003cp\u003eCutting or splicing the cable changes the resonant loop impedance parameters, which invalidates factory calibration and introduces tracking measurement drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operational boundary for the unarmored coaxial cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe raw materials and high-temperature outer jacket maintain technical structural properties across an operational range up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is cross-talk suppression managed when installing multiple 25 mm probes side by side?\u003c\/p\u003e\n\u003cp\u003eEngineers must enforce large lateral spacing distances between adjacent probe bodies to prevent magnetic fields from bleeding together.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe component require an external DC power supply terminal block hookup?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive transducer assembly that receives its operating RF excitation directly from the matched 3300 XL Proximitor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical failure occurs if the housing is installed with fewer than 5 full threads of engagement?\u003c\/p\u003e\n\u003cp\u003eLow thread engagement increases stress during structural vibration, leading to stripped threads, loose alignment, or total mechanical failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat baseline target configuration is verified during field gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eTechnicians measure the DC bias output via the Proximitor to check that the static installation clearance sits squarely inside the tracking window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026719002797,"sku":"330851-02-000-060-50-00-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_111.jpg?v=1783492625"},{"product_id":"330876-02-10-00-00-bently-nevada-proximity-probes-3300-xl-series","title":"330876-02-10-00-00 Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330876-02-10-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330876\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting displacement measurement across 3300 XL Series platforms. The hardware measures high-amplitude static and dynamic gaps between the 50 mm tip face and a target surface, tracking high-frequency eddy-current parameter transformations generated by the proximity sensor assembly.\u003c\/p\u003e\n\u003ch3\u003eOption Options and Nomenclature\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330876: Base hardware reference identifier for the 3300 XL 50 mm proximity probe system component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Probe case type option specifying an M14 x 1.5 metric mounting thread pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total length configuration assigning a 1.0 meter (3.3 feet) integrated lead construction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Armor configuration option detailing a high-temperature FluidLoc cable without steel weave layering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Certification approval matrix selecting standard production documentation with no agency approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Metrics\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330876-02-10-00-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Housing Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM14 x 1.5 metric threads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Armor Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Temperature FluidLoc Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification Layer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor driven via high-frequency excitation from paired Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 cm x 6.0 cm x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe large 50 mm coil head dictates a wide magnetic field spread, adjusting the eddy-current probe scaling metrics to linearize tracking across broad displacement spans. Managing dynamic rotor dynamics within low-frequency or high-displacement environments demands correct field calibration. Field engineers execute gap voltage validation procedures referencing a standard -10 VDC targets configuration, verifying that the mechanical installation alignment matches the exact center point of the linear system window while external shield properties deliver proper cross-talk suppression against adjacent sensor interference loops.\u003c\/p\u003e\n\u003ch3\u003ePackage Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 * 330876-02-10-00-00 Proximity Probe Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 * Coaxial Connector Insulator Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Instructions\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation and Thread Engagement\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHand-thread the M14 x 1.5 housing into the custom machine bracket, confirming no less than 5 full threads of engagement before locking down the hardware position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the sensor positioning relative to the shaft face until the linked diagnostic voltmeter measures the target initial bias voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCabling Run and Shield Terminal Integration\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the 1.0 meter FluidLoc cable layout through high-clearance flexible conduits, separating the wire run from areas prone to mechanical pinching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAttach the outer shielding link directly to the field termination block terminal, verifying isolation from intermediate structural machine grounding loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swap removal of the sensor line permitted while the matching proximity transmitter card remains active?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware allows hot-swap isolation and line reconnection without generating diagnostic errors across the internal bus system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific issue occurs if the target piece has a face dimension smaller than the 50 mm tip?\u003c\/p\u003e\n\u003cp\u003eSmaller targets alter the eddy-current probe scaling line, which reduces calibration accuracy and creates measurement distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the field gap voltage validation verified on a standard 3300 XL loop setup?\u003c\/p\u003e\n\u003cp\u003eTechnicians measure the gap via the buffer terminal port using a high-impedance multimeter, aiming for a -10 VDC baseline value.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this FluidLoc cable structure protect against aggressive process fluids or high humidity?\u003c\/p\u003e\n\u003cp\u003eYes, the high-temperature FluidLoc structure contains internal blocks designed to stop oil or moisture tracking through the wire jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is cross-talk suppression an important parameter for these large 50 mm elements?\u003c\/p\u003e\n\u003cp\u003eThe broad electromagnetic field can bleed into adjacent sensors if they are mounted closer than the minimum required separation distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the displacement tracking loop if an extension cable of incorrect length is added?\u003c\/p\u003e\n\u003cp\u003eAdding wrong extension lengths shifts the loop resonance parameters, which invalidates the calibration slope of the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the upper operating temperature limit for the main 50 mm sensing head?\u003c\/p\u003e\n\u003cp\u003eThe probe head assembly maintains physical and mechanical properties over an operating range up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external power source directly attached to the M14 threaded sensor housing?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive sensing coil that receives RF power from the matched Proximitor unit via the coaxial connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026752753837,"sku":"330876-02-10-00-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--1_da03ff7c-5f53-46ca-8805-b4732b53b8e8.jpg?v=1783666020"},{"product_id":"330851-02-020-060-50-00-00-bently-nevada-3300-xl-series-proximity-probes","title":"330851-02-020-060-50-00-00 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in 3300 XL 25 mm Proximity Transducer systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-02-020-060-50-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes) provides direct physical\/electrical execution. The instrument captures differential distance metrics between the 25 mm sensor tip face and a conductive target area, translating structural deviations into modulated high-frequency eddy-current impedance shifts prior to external signal processing.\u003c\/p\u003e\n\u003ch3\u003eModel Parameter Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330851: Base model numeric code for the 3300 XL 25 mm proximity probe hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Threaded case type option selecting an M30 x 2 metric thread profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e020: Unthreaded case length configuration assigning 20 mm (approx. 0.8 in) of smooth barrel length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e060: Overall case length choice defining 60 mm of total case housing footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50: System total length parameter dictating a 5.0 meters (16.4 feet) length standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Armor selection variant selecting a standard fluid-resistant cable layer without flexible metal armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency certification configuration specifying standard delivery with no approvals required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-020-060-50-00-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElement Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM30 x 2 metric profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive magnetic inductive coil assembly driven via external Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 cm x 22.5 cm x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm sensor tip area governs specific eddy-current probe scaling coefficients designed to measure high-amplitude displacement parameters during dynamic machinery cycles. Accurate evaluation of rotor dynamics is maintained through gap voltage validation tests, setting the resting physical position relative to -10 VDC targets. Advanced structural shielding and component geometry yield native cross-talk suppression properties that prevent adjacent RF signal interference paths when multiple large-diameter elements operate inside shared oil-deflector frames.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1* 330851-02-020-060-50-00-00 Proximity Probe Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1* Coaxial Terminal ClickLoc Protective Shell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Torquing and Depth Configuration\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the M30 x 2 threaded housing into the bracket interface, keeping a thread depth allocation of no less than 5 full engaged threads inside the fixture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotate the sensor case body to establish the required mechanical gap, ensuring the terminal multimeter tracks the live voltage to the standard midpoint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Routing and Shield Interconnects\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePlace the 5.0 meters non-armored cable path inside clean galvanized rigid conduits to isolate the jacket polymer from surrounding thermal sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate the outer coaxial shield layout at the central Proximitor ground rail terminal, preventing parallel structural earth loops along the machinery body.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable line permitted to be hot-swapped while the main rack monitor loop is powered up?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware structure permits active hot-swap insertion without corrupting adjacent vibration measurement channels across the instrument bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the on-site gap voltage validation process performed during standard installation setup?\u003c\/p\u003e\n\u003cp\u003eThe loop is verified by connecting a digital voltmeter to the Proximitor signal out contacts, reading a target baseline value of -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes a shift in target metallurgy alter the factory default eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eYes, the scale slope relies on AISI 4140 steel, and utilizing alternative alloys will require separate laboratory re-calibration procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the proximity module signal if the total loop length option is misconfigured?\u003c\/p\u003e\n\u003cp\u003eUsing incorrect electrical line lengths induces internal resonance changes, creating amplitude calibration errors and signal distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the probe tip geometry provide integrated cross-talk suppression inside the bearing house?\u003c\/p\u003e\n\u003cp\u003eThe internal coil wraps are shielded to concentrate the magnetic field forwards, limiting radial emission escape zones between sensor tips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this non-armored variant include moisture protection features along the main wire jacket?\u003c\/p\u003e\n\u003cp\u003eYes, the standard jacket material features high chemical resistance designed to isolate internal conductors against standard turbine oil mist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum safe operating temperature exposure for the 25 mm probe tip block?\u003c\/p\u003e\n\u003cp\u003eThe front element tip assembly is rated to operate securely across a standard structural thermal range up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external power source directly wired to this sensor element?\u003c\/p\u003e\n\u003cp\u003eNo, this passive probe receives high-frequency drive current solely through the coaxial terminal of its paired 3300 XL Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026754261165,"sku":"330851-02-000-060-50-00-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_09_50cddf55-d387-4aba-9fd0-ea472354a3a9.jpg?v=1783666015"},{"product_id":"330851-02-000-050-90-00-05-bently-nevada-3300-xl-series-proximity-probe","title":"330851-02-000-050-90-00-05 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-02-000-050-90-00-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting dynamic and static displacement measurements within 3300 XL 25 mm Proximity Transducer platforms. The hardware tracks proximity variations by generating high-frequency eddy currents at the sensor tip, providing raw physical voltage inputs corresponding to the gap distance changes of the monitored shaft target.\u003c\/p\u003e\n\u003ch3\u003eStructural Option Codes Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330851: Main catalog base identifier for the 3300 XL 25 mm proximity probe hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Case thread type option denoting an M30x2 metric thread profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e000: Unthreaded length specification indicating 0 mm of unthreaded smooth casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e050: Overall case length specification indicating a 50 mm total housing shell.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90: Total system length option selecting a 9.0 meters (29.5 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Armor option indicating no flexible stainless steel conduit armor over the outer jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval specification establishing certification under multiple international hazardous area standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-000-050-90-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Tip Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mm diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM30x2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (29.5 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor element powered via external Proximitor excitation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 cm x 22.5 cm x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm transducer layout employs precise eddy-current probe scaling configurations optimized for large-scale shaft movement tracking and machinery rotor dynamics. During baseline machine commissioning calibration, the system maps output data against a predefined gap voltage validation curve targeting specific negative VDC indicators. Built-in internal cross-talk suppression paths insulate the core high-frequency transmission coil from neighboring instrumentation arrays, maintaining clean physical signals in tight bearing block structures.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330851-02-000-050-90-00-05 Proximity Transducer Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Coaxial Connector Protection End Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Threading and Case Alignment\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the M30x2 probe housing directly into the calibrated bracketry, verifying a minimum mechanical thread engagement depth of 5 full threads before final locking torque is applied.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotate the sensor shaft inside the mount while monitoring live DC output potential until the designated operational clearance target is locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePhysical Cable Routing and Shield Termination\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFasten the 9.0 meters non-armored lead wire along protective routing channels using non-conductive, padded tie wraps spaced to prevent friction insulation wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the extension cables clear of power lines to block high-voltage interference fields inside the cabinet framework.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this 25 mm proximity sensor support dynamic replacement while the host TSI rack is energized?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware allows technicians to disconnect or swap out individual sensor nodes without generating faults in adjacent channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the baseline gap voltage validation standard executed at the installation site?\u003c\/p\u003e\n\u003cp\u003eTechnicians measure the raw negative DC potential at the monitor proxy port to calibrate the core resting position of the shaft.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat parameters define the active eddy-current probe scaling performance for this 25 mm model?\u003c\/p\u003e\n\u003cp\u003eThe wide 25 mm tip face dictates a broader magnetic field footprint, expanding the maximum linear measuring path over standard smaller tips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe element run natively without an active Proximitor processing module?\u003c\/p\u003e\n\u003cp\u003eNo, this device is an unpowered inductive sensor that relies entirely on high-frequency driver loops supplied by a paired Proximitor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical step protects the sensor lines from cross-talk suppression failures when grouped?\u003c\/p\u003e\n\u003cp\u003eProbes must be physically separated by standard radial distance limits to prevent overlapping fields from bleeding across conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of electrical terminator is fitted to the tail of the 9.0 meters cable?\u003c\/p\u003e\n\u003cp\u003eThe integrated line ends in a miniature coaxial click-loc push-lock connector designed to interface with matching extension cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the non-armored option change the operating temperature thresholds of the probe jacket?\u003c\/p\u003e\n\u003cp\u003eNo, the omission of steel armor lowers the total structural weight but retains the standard physical operational bounds up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is structural shield grounding handled for the integrated transducer lines?\u003c\/p\u003e\n\u003cp\u003eThe outer braided shield must connect to a clean instrumentation ground block inside the junction box while leaving the probe body isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026767433901,"sku":"330851-02-000-050-90-00-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-59_7930bb3a-62a4-42db-87c5-f0936cd98648.jpg?v=1783666001"},{"product_id":"330876-02-10-01-00-bently-nevada-3300-xl-nsv-series-50-mm-proximity-probe","title":"330876-02-10-01-00 Bently Nevada 3300 XL NSV Series 50 mm Proximity Probe","description":"\u003cp\u003eConfigured for non-contact shaft position and vibration monitoring in TSI platforms, the \u003cstrong\u003eBently Nevada 330876-02-10-01-00\u003c\/strong\u003e (\u003cstrong\u003e330876\u003c\/strong\u003e 50 mm Proximity Probe) provides direct physical execution of displacement sensing within the 3300 XL NSV system.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330876: 3300 XL NSV Proximity Probe\u003c\/li\u003e\n\u003cli\u003e02: Probe case length (50 mm)\u003c\/li\u003e\n\u003cli\u003e10: Total length (1.0 meter)\u003c\/li\u003e\n\u003cli\u003e01: Connector option (Miniature coaxial ClickLoc connector)\u003c\/li\u003e\n\u003cli\u003e00: Agency approval (Not required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Hardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330876-02-10-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm x 180 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor (powered by Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e0.5 mm to 2.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL NSV system utilizes specific eddy-current probe scaling to accommodate narrow-range measurements required for small-shaft applications. Achieving accurate rotor dynamics data necessitates strict gap voltage validation; technicians should target a -10 VDC baseline when the probe is positioned at the electrical center of its range. Effective cross-talk suppression is achieved by following factory-defined minimum separation distances between adjacent sensors to prevent carrier frequency interference within the transducer system.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x 330876 50 mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1x Connector protector\u003c\/li\u003e\n\u003cli\u003e1x Technical product datasheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable Routing: Ensure coaxial cables are installed within grounded steel conduit to isolate signals from electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTorque Requirements: Apply appropriate torque to the mounting nut as specified in the manual to maintain structural integrity during machine operation.\u003c\/li\u003e\n\u003cli\u003eGap Setting: Verify the gap voltage with a high-impedance multimeter at the Proximitor monitor terminal before finalizing the lock-nut position.\u003c\/li\u003e\n\u003cli\u003eConnector Sealing: Utilize the provided ClickLoc protector to ensure the integrity of the coaxial connection in environments exposed to hydrocarbons or moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat distinguishes the NSV probe from standard 3300 XL probes?\u003c\/p\u003e\n\u003cp\u003eThe NSV series is specifically engineered for non-contact measurements on shafts with small diameters where standard probes may exhibit excessive side-view interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs field calibration of the cable length permitted?\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 XL NSV system is calibrated as a matched set (Probe, Extension Cable, and Proximitor). Modifying lengths will alter the electrical characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the -10 VDC gap voltage?\u003c\/p\u003e\n\u003cp\u003eThe -10 VDC target positions the probe in the center of the linear measurement range, allowing for maximum signal swing in both directions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be connected to a standard 3300 XL Proximitor?\u003c\/p\u003e\n\u003cp\u003eNo. The NSV probe must be paired with an NSV-specific Proximitor to ensure correct system scaling and frequency response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does probe tip material affect the measurement?\u003c\/p\u003e\n\u003cp\u003eThe probe is calibrated for AISI 4140 steel; using a different target material will require a correction factor or recalibration of the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the limitations regarding hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe probe can be replaced while the system is powered, but the change will induce a discontinuity in the monitored signal, potentially triggering alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the probe be grounded?\u003c\/p\u003e\n\u003cp\u003eThe probe case is grounded through the mounting bracket; verify that the bracket maintains a low-impedance path to the machine frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum operating temperature of the probe tip?\u003c\/p\u003e\n\u003cp\u003eThe probe tip is rated for continuous operation up to +177 deg C. Exceeding this limit will degrade the polymer material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026775625901,"sku":"330876-02-10-01-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian11_4b4706c3-f9a5-44d3-802c-ae1e5bc9abf1.jpg?v=1783411617"},{"product_id":"330850-91-05-bently-nevada-3300-xl-25-mm-proximitor-sensor","title":"330850-91-05  Bently Nevada 3300 XL 25 mm Proximitor Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330850-91-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330850\u003c\/strong\u003e Proximitor Sensor, operates as a dedicated hardware component for casing-to-shaft proximity signal conditioning within machine monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering \u0026amp; Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330850: 3300 XL 25 mm Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003e91: 9.0 meters (29.5 feet) system length\u003c\/li\u003e\n\u003cli\u003e05: Multiple agency approval ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330850-91-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.8 x 3.5 x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDefined by 3300 XL system architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Scale Factor\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTSI and Mechanical Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL series utilizes high-frequency eddy-current probe scaling to convert target proximity into a linear electrical output. System performance is contingent upon precise gap voltage validation, typically maintained at -10 VDC to ensure the probe operates within its linear measurement range. The sensor architecture includes active cross-talk suppression, permitting operation in multi-channel proximity arrays without mutual signal interference. Accurate rotor dynamics data acquisition relies on maintaining system integrity across the specified 9.0 m cable length.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 330850-91-05 Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003e1 Instruction and technical documentation packet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Secure the sensor within an enclosure or on a DIN rail, ensuring the housing is protected from direct environmental exposure.\u003c\/li\u003e\n\u003cli\u003eCabling: Use factory-terminated coaxial cables to ensure impedance matching; avoid sharp bends or mechanical stress on the ClickLoc connectors.\u003c\/li\u003e\n\u003cli\u003eShielding: Terminate the cable shield at the designated ground reference to maintain RFI\/EMI immunity in industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerification: Confirm system calibration post-installation by checking the gap voltage at the sensor output terminals against expected mechanical clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs this sensor compatible with 8 mm probes?\u003c\/p\u003e\n\u003cp\u003eNo. The 330850 Proximitor is specifically calibrated for 25 mm probes; electrical impedance mismatch will occur if connected to an 8 mm probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the system cable length is modified in the field?\u003c\/p\u003e\n\u003cp\u003eSystem calibration is fixed to the 9.0 m length. Modifying cable length alters the circuit capacitance and inductance, leading to significant measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the Proximitor be hot-swapped?\u003c\/p\u003e\n\u003cp\u003eThe unit does not support hot-swapping. Power must be disconnected from the loop to avoid electrical transients that may damage internal components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of temperatures exceeding 100 deg C?\u003c\/p\u003e\n\u003cp\u003eOperating above the 100 deg C limit causes drift in the sensor scale factor and potential failure of internal electronic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the Average Scale Factor (ASF) affect output?\u003c\/p\u003e\n\u003cp\u003eThe 0.787 V\/mm ASF is the constant ratio of output voltage change to input displacement; deviations indicate a fault in the probe or sensor loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the \"91\" option include extension cables?\u003c\/p\u003e\n\u003cp\u003eThe \"91\" code defines the total system length (9.0 m), which includes the probe, extension cable, and Proximitor sensor assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there specific grounding requirements for the sensor case?\u003c\/p\u003e\n\u003cp\u003eYes. The sensor case must be connected to a clean instrument ground to maintain the signal-to-noise ratio required for precision vibration monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the significance of the 20 mV\/mil rating?\u003c\/p\u003e\n\u003cp\u003eThis is the standard engineering unit sensitivity for the sensor, used by monitoring systems to interpret the raw voltage output as physical distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026781950125,"sku":"330850-91-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330850-91-05_35.jpg?v=1783409569"},{"product_id":"330851-06-000-070-10-00-05-bently-nevada-proximity-probe-3300-xl-25-mm","title":"330851-06-000-070-10-00-05 Bently Nevada Proximity Probe 3300 XL 25 mm","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330851-06-000-070-10-00-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330851-06-000-070-10-00-05\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for non-contact displacement measurement within vibration monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: 3300 XL 25 mm\u003c\/li\u003e\n\u003cli\u003eThread Specification: M39 x 1.5\u003c\/li\u003e\n\u003cli\u003eUnthreaded Length: 0 mm\u003c\/li\u003e\n\u003cli\u003eTotal Length: 1.0 meter (3.3 feet)\u003c\/li\u003e\n\u003cli\u003eArmor Option: None\u003c\/li\u003e\n\u003cli\u003eAgency Approval: Multiple Approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330851-06-000-070-10-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e25 x 22 x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eN\/A (Passive transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Properties\u003c\/h3\u003e\n\u003cp\u003eThe transducer assembly employs eddy-current probe scaling to convert target proximity into a linear voltage signal. System accuracy is contingent upon rigorous gap voltage validation to maintain -10 VDC targets under nominal operating conditions. During installation, technicians must account for rotor dynamics to minimize signal distortion, and ensure adequate cross-talk suppression by maintaining spatial isolation from adjacent high-frequency sensing elements within the machine casing.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e1 x 330851-06-000-070-10-00-05 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x M39 x 1.5 mounting nut\u003c\/li\u003e\n\u003cli\u003e1 x Installation documentation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Ensure the M39 x 1.5 thread is fully seated in the support bracket; avoid mechanical stress on the probe body during tightening.\u003c\/li\u003e\n\u003cli\u003eGap Setting: Calibrate the probe-to-target distance to achieve the required DC voltage offset for the target material.\u003c\/li\u003e\n\u003cli\u003eGrounding: Verify the probe tip is electrically isolated from the mounting structure to prevent ground loop interference.\u003c\/li\u003e\n\u003cli\u003eRouting: Ensure the cable path minimizes exposure to high-temperature zones and avoids proximity to high-current conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the specific application for the 25 mm probe tip?\u003c\/p\u003e\n\u003cp\u003eThe 25 mm tip diameter provides an extended linear range, suitable for measuring large-amplitude displacements on massive rotating machinery components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model require an extension cable?\u003c\/p\u003e\n\u003cp\u003eThis model is a probe assembly; it must be connected to a matching Bently Nevada extension cable and Proximitor sensor calibrated for the 25 mm system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the M39 thread used in installation?\u003c\/p\u003e\n\u003cp\u003eThe M39 x 1.5 thread is designed for heavy-duty mounting, allowing for precise axial adjustment of the probe tip relative to the target surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eThe Multiple Approvals suffix indicates compliance with various international hazardous area certification standards; verify specific regional requirements before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of target material on signal output?\u003c\/p\u003e\n\u003cp\u003eThe output signal is calibrated for 4140 steel; other materials will require a known scaling factor to maintain displacement measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe tip sensitive to fluid immersion?\u003c\/p\u003e\n\u003cp\u003eThe probe is designed for operation in common industrial lubricants and gases; ensure chemical compatibility with the probe tip material before extended immersion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the gap voltage be measured?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance digital multimeter to measure the DC voltage at the Proximitor sensor output terminals during the static gap calibration process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the minimum clearance between probes?\u003c\/p\u003e\n\u003cp\u003eTo maintain cross-talk suppression, adhere to the minimum spacing guidelines defined in the Bently Nevada 3300 XL installation manual to avoid signal beating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026809835693,"sku":"330851-06-000-070-10-00-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian10_67054478-2c5a-43ef-a5a7-f6f545f27a96.jpg?v=1782790934"},{"product_id":"330851-000-070-10-00-05-bently-nevada-3300-xl-25-mm-proximity-probe","title":"330851-000-070-10-00-05 Bently Nevada 3300 XL 25 mm Proximity Probe","description":"\u003cp\u003eConfigured for large-gap displacement sensing in industrial monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-000-070-10-00-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction of rotor position and vibration within expansive mechanical clearances.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix and Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330851-000-070-10-00-05 identifier is defined by the following specifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e000: Minimum unthreaded length of 0 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e070: Maximum unthreaded length of 0.7 inches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 1.0 meter (3.3 feet) total probe length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No armor construction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Multiple agency approval ratings (CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-000-070-10-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 x 22 x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult 3300 XL system manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 25 mm probe is engineered to facilitate precise measurement in applications requiring larger linear ranges than standard 8 mm probes. Successful integration requires accurate eddy-current probe scaling, as the larger tip diameter alters the electromagnetic field characteristics. Field commissioning must include gap voltage validation to target -10 VDC at the Proximitor sensor output, ensuring the system operates within its linear region. Cross-talk suppression is maintained through the system's high-frequency carrier design, mitigating interference when multiple probes are installed in high-density monitoring arrays.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330851-000-070-10-00-05 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Locknut and mounting hardware set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Regulatory compliance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the mounting bracket provides a rigid support to prevent resonant vibration from affecting the measurement signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the probe position to the required gap, then tighten the mounting nuts to lock the probe in place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the probe cable through dedicated conduit or raceways, away from high-current power cables to prevent electromagnetic noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck for tight bends at the probe-to-cable transition point, which can cause internal conductor stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is a 25 mm probe used instead of an 8 mm probe?\u003c\/p\u003e\n\u003cp\u003eThe 25 mm probe provides a significantly larger linear range, allowing for accurate monitoring of machinery with greater shaft movement or thermal expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require a specific Proximitor sensor?\u003c\/p\u003e\n\u003cp\u003eYes, this probe must be paired with a 25 mm 3300 XL Proximitor sensor, as the internal circuitry is impedance-matched specifically for this transducer size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this probe in a hazardous area?\u003c\/p\u003e\n\u003cp\u003eYes, the 05 suffix indicates the probe carries multiple agency approvals (CSA, ATEX, IECEx) for use in designated hazardous atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of probe unthreaded length?\u003c\/p\u003e\n\u003cp\u003eUnthreaded length defines the portion of the probe case without mounting threads; this is chosen based on the thickness of the machine housing and the required gap distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable shield grounded?\u003c\/p\u003e\n\u003cp\u003eThe probe cable shield should be grounded at the monitor rack terminal to prevent ground loops that could degrade signal resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is signal continuity checked?\u003c\/p\u003e\n\u003cp\u003eContinuity can be verified by measuring the DC resistance between the center conductor and the outer connector body; ensure readings align with system specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip is scratched?\u003c\/p\u003e\n\u003cp\u003eSurface damage to the probe tip can distort the eddy-current field, leading to non-linear output and measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I field-replace the connector?\u003c\/p\u003e\n\u003cp\u003eNo, the connector is factory-swaged to the coaxial cable; attempting to replace or repair it will permanently alter the impedance of the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026810458285,"sku":"330851-000-070-10-00-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--2_20e251e3-2c16-4654-8042-a1b420350085.jpg?v=1782790016"},{"product_id":"bently-nevada-330851-05-000-040-50-01-05-proximity-transducer-3300-xl-series","title":"Bently Nevada 330851-05-000-040-50-01-05 Proximity Transducer 3300 XL Series","description":"\u003cp\u003eConfigured for high-frequency vibration monitoring in turbomachinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-05-000-040-50-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal acquisition via eddy-current induction to measure shaft displacement and position.\u003c\/p\u003e\n\u003ch3\u003eCatalog Suffix Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330851\u003c\/strong\u003e: 3300 XL 25 mm Proximity Probe, standard configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 1-12 UNF-2A thread probe case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e000\u003c\/strong\u003e: Minimum unthreaded length, 0 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e040\u003c\/strong\u003e: Case length, 40 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e50\u003c\/strong\u003e: Total probe length, 5.0 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: With SST (Stainless Steel) armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Multiple agency approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-05-000-040-50-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.5 x 21 x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-12 UNF-2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Sensing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 25 mm transducer system relies on the conversion of high-frequency radio waves into a magnetic field, which induces eddy currents on the target surface. Proper scaling requires adherence to the nominal sensitivity of 7.87 mV\/µm (200 mV\/mil). Calibration must be performed against the specified target material (typically AISI 4140 steel) to ensure linear output. The system requires a nominal -10 VDC gap voltage bias for linear operation within the designated 0 mm to 12.7 mm (500 mil) linear range. Cross-talk suppression is maintained through integrated radio-frequency shielding to prevent interference in high-density probe installations.\u003c\/p\u003e\n\u003ch3\u003eDelivery Components\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 3300 XL 25 mm Proximity Probe (with integral cable and armor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Certificate of Conformance \/ Regulatory documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMounting and Signal Integration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Positioning\u003c\/strong\u003e: Ensure the probe tip is installed perpendicular to the target surface. Utilize the 1-12 thread for depth adjustment; tighten locking nuts to ensure structural stability against vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Requirements\u003c\/strong\u003e: The SST armor must be protected from sharp bends. Ensure the minimum bend radius is maintained to prevent inner cable dielectric deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: The probe case must be electrically isolated from the machinery housing if required by the specific installation drawing to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Continuity\u003c\/strong\u003e: Verify termination at the Proximitor sensor interface to ensure the -10 VDC supply is stable before final gap setting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum linear range for this 25 mm probe?\u003c\/p\u003e\n\u003cp\u003eThe linear measurement range is typically 12.7 mm (500 mils), provided the gap is set to the correct center-line voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the SST armor field-replaceable?\u003c\/p\u003e\n\u003cp\u003eNo, the armor is factory-integrated with the probe assembly. Any attempt to remove or modify the armor will compromise the probe's integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require a specific target material?\u003c\/p\u003e\n\u003cp\u003eStandard calibration is based on AISI 4140 steel. Different target materials will necessitate a correction factor for the output scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the effect of oil film on the probe performance?\u003c\/p\u003e\n\u003cp\u003eThe eddy-current principle is largely unaffected by oil, water, or steam, making it suitable for internal turbine bearing monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the gap be verified?\u003c\/p\u003e\n\u003cp\u003eUse a calibrated feeler gauge or a micrometer to verify the physical gap against the Proximitor output voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used without the 3300 XL Proximitor?\u003c\/p\u003e\n\u003cp\u003eNo, the probe is a passive component and requires the matched 3300 XL Proximitor sensor for signal conditioning and linearization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the significance of the 5.0 meter cable length?\u003c\/p\u003e\n\u003cp\u003eThe total length (probe + extension) is tuned to the specific inductance\/capacitance of the system; shortening the cable will invalidate the calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe sensitive to temperature fluctuations?\u003c\/p\u003e\n\u003cp\u003eYes, thermal expansion can alter the gap. Ensure the mount material matches the target expansion coefficient for high-accuracy stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026822287533,"sku":"330851-05-000-040-50-01-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--3_0cc23b5b-c1ce-4f47-a1a8-552bd148b2ed.jpg?v=1782789563"},{"product_id":"330850-51-cn-bently-nevada-3300-xl-25-mm-series-proximitor-sensor","title":"330850-51-CN Bently Nevada 3300 XL 25 mm Series Proximitor Sensor","description":"\u003cp\u003eConfigured for displacement and vibration measurements in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330850-51-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330850\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor) provides direct physical\/electrical execution. This signal conditioning hardware processes high-frequency carrier signals from a 25 mm proximity probe, converting inductive impedance changes into a proportional voltage output ranging from -2 VDC to -18 VDC. The unit serves as the interface between the transducer and monitoring instrumentation, supporting continuous observation of shaft dynamic behavior.\u003c\/p\u003e\n\u003ch3\u003ePart Number Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330850\u003c\/strong\u003e: 3300 XL 25 mm Proximitor Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e51\u003c\/strong\u003e: System length option (5.0 meters \/ 16.4 feet system).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Agency approval option (China-specific compliance).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330850-51-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 cm x 6.0 cm x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-18 VDC to -24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 mm to 3.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) +\/- 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz to 10 kHz (+\/- 1 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm proximity sensing system is optimized for target surfaces where large gap measurements are required. Accurate eddy-current probe scaling is mandatory, requiring the system to be calibrated against AISI 4140 steel. Field technicians must perform gap voltage validation (-10 VDC targets) at the Proximitor output during setup to ensure the probe tip is centered within the 1.0 mm to 3.0 mm linear range. Proper scaling is critical for reliable rotor dynamics analysis, particularly when monitoring large-clearance fluid-film bearings. Cross-talk suppression must be enforced by maintaining required spatial separation between multiple sensors to prevent electromagnetic interference within the high-frequency measurement loop.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330850-51-CN Proximitor Sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Technical Data Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation Reference Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the Proximitor to a DIN-rail or standard mounting plate within a clean, dry enclosure to ensure long-term stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the mounting surface is grounded to a common instrumentation reference to minimize electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Signal Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUtilize shielded twisted-pair cabling for all output signal paths to the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain physical separation from high-voltage AC cables to avoid signal degradation or induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the -18 VDC to -24 VDC power supply remains within the specified range to avoid output voltage clipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the Proximitor output signal compatible with PLC analog input cards?\u003c\/p\u003e\n\u003cp\u003eThe output is a negative DC voltage. A signal converter or an appropriate negative-voltage-capable analog input module is required for integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this Proximitor be used with a 5 m or 9 m system cable?\u003c\/p\u003e\n\u003cp\u003eThe model 330850-51-CN is specifically calibrated for a 5.0 m system length; deviation from this length will alter the system impedance and calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the device hot-swappable during system operation?\u003c\/p\u003e\n\u003cp\u003eThe sensor can be removed while the loop is powered, but this will trigger a channel fault or \"Not OK\" status in the connected monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify the linear range in the field?\u003c\/p\u003e\n\u003cp\u003eUsing a static calibration fixture or a manual micrometer, verify the voltage change matches the 7.87 V\/mm sensitivity as the probe moves through the 1-3 mm range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the supply voltage drops below -18 VDC?\u003c\/p\u003e\n\u003cp\u003eThe Proximitor will fail to maintain the necessary carrier wave amplitude, resulting in increased signal noise or complete loss of the output voltage signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this sensor support HART or digital communication protocols?\u003c\/p\u003e\n\u003cp\u003eNo, the 330850 is a purely analog signal conditioning device and does not support digital handshaking or HART protocol modulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I clean the coaxial connector during installation?\u003c\/p\u003e\n\u003cp\u003eUse a clean, dry, non-conductive electronic contact cleaner. Ensure no residue remains, as it can cause impedance shifts in the high-frequency path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of an \"Open\" or \"Short\" circuit in the probe lead?\u003c\/p\u003e\n\u003cp\u003eAn open or short circuit will cause the Proximitor output to swing to the negative supply rail or ground, triggering an \"Not OK\" status in the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026840080557,"sku":"330850-51-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330850-51-CN_1.jpg?v=1782723119"},{"product_id":"330850-51-05-bently-nevada-3300-xl-series-proximitor-sensor","title":"330850-51-05 Bently Nevada 3300 XL Series Proximitor Sensor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330850-51-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor, operates as a dedicated hardware component for processing non-contacting displacement signals within Turbine Supervisory Instrumentation platforms. The device supplies high-frequency excitation energy to a 25 mm proximity probe and conditions the modulated return parameters into a continuous analog voltage proportional to machine differential expansion or thrust position.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330850-51-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 x 3.5 x 7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +85 deg C (Associated probe rated to +200 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRequires nominal -24 VDC input rail via monitor rack supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExtended Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 mm (500 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAverage Scale Factor (ASF): 0.787 V\/mm (20 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet) total electrical loop tuning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStructural Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP67 rated dust and water immersion barrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated 35 mm DIN-rail mount base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField Wiring Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eToolless SpringLoc terminal strips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Approvals option (including CE, ATEX, IECEx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 330850-51-05 instrumentation circuit executes precise eddy-current probe scaling to linearize signal feedback across a broad 12.7 mm displacement zone. To achieve accurate physical measurements, the system requires matching total loop cable lengths to the 5.0 meter electrical constant. The hardware features improved internal RFI\/EMI immunity filters that block parasitic radiation from adjacent communication devices, providing robust cross-talk suppression and preventing noise injection from distorting low-frequency rotor dynamics signals.\u003c\/p\u003e\n\u003ch3\u003eComponent Interfacing FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can a 3300 XL 25 mm Proximitor Sensor operate with older, non-3300 XL series transducer components?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The device features backward compatibility with legacy non-3300 XL 25 mm transducer parts. When mixing generations, the baseline system metrics adapt to the matching performance limits of the legacy components.\u003c\/p\u003e\n\u003cp\u003eQ: What are the electrical consequences if the total probe and extension cable length drops below the 5.0 meter specification?\u003c\/p\u003e\n\u003cp\u003eA: Shortening the loop changes the configured loop capacitance and inductance. This shift skews the nominal 0.787 V\/mm Average Scale Factor, distorting the output accuracy and invalidating the tracking alignment during machine expansion phases.\u003c\/p\u003e\n\u003cp\u003eQ: How do SpringLoc terminal strips behave under conditions of high mechanical machinery vibration?\u003c\/p\u003e\n\u003cp\u003eA: The SpringLoc terminal configuration maintains continuous spring-biased clamping force onto the field conductor core. This mechanical tension eliminates terminal loosening and intermittent open circuits common to screw-type terminals in high-vibration instrumentation racks.\u003c\/p\u003e\n\u003ch3\u003eField Layout and Installation Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Placement Constraints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSnap the sensor directly onto an earthed 35 mm DIN rail, checking that the metallic grounding foot seats securely against the rail to establish a low-impedance path for RFI\/EMI shield currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Validation Tuning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect a calibrated digital multimeter to the transmitter signal terminal blocks and adjust the probe position through its bracket until the baseline gap voltage validation reads the designated mid-scale DC target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Transducer Compensated Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen setting up a ramp-viewing differential expansion array, mount both 25 mm probes with sufficient lateral spacing to eliminate overlapping eddy-current target zones and prevent cross-talk errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Terminal Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the field wiring cables through clean liquid-tight conduit paths, verifying the outer insulation jackets are clamped without pinch faults inside the terminal compartment to preserve the IP67 sealing profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandard Delivery Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Line Components:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne Bently Nevada 330850-51-05 3300 XL 25 mm Proximitor Sensor module, integrated DIN-rail mount clips, and raw terminal plug headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparated Optional Additions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm non-contacting proximity probes, matching coaxial extension cables, external power supplies, and metal instrumentation boxes must be sourced via separate lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Profile and Handling Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsignment Processing Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivery time: 2-7 days when payment finish, utilizing prioritized express air courier dispatch via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Static Industrial Packaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDispatched in heavy-gauge anti-static industrial packaging using shock-absorbing outer containers to safeguard the precision internal oscillator and demodulator networks during international transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026885791917,"sku":"330850-51-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330850-51-05_3.jpg?v=1780047619"},{"product_id":"330854-080-24-cn-bently-nevada-proximity-probes-3300-xl-series","title":"330854-080-24-CN Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330854-080-24-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330854\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute non-contact displacement signal routing across 3300 or 3500 Turbine Supervisory Instrumentation (TSI) platforms. The hardware maintains impedance-matched electrical continuity between a 25 mm proximity probe and an external Proximitor sensor, enabling high-range differential expansion and rotor position tracking.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBase Model (330854):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length Option (080):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.0 meters (26.2 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Type Option (24):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh Temperature FluidLoc cable variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval Option (CN):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSA, ATEX, and IECEx hazardous area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-080-24-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 x 18 x 2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive coaxial transmission path with zero nominal current draw\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 meters (26.2 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc moisture-blocking construction\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Component Matching\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 25 mm Proximity Transducer systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 330854-080-24-CN extension cable is specifically manufactured with strict physical parameter tolerances to control total loop capacitance and inductance. This precise impedance tuning ensures that the factory eddy-current probe scaling remains linear across the wide operating envelope of the 25 mm transducer system. The internal coaxial shielding parameters are optimized for cross-talk suppression, preventing external radio frequency fields or adjacent high-voltage machinery cables from inducing noise into the sensor circuit, maintaining clear signal pathing for tracking rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eHardware Interfacing FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can this 8.0 meter extension cable be paired with an unarmored 1.0 meter 25 mm proximity probe?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The combined electrical length of the probe and extension cable must match the required driver hardware configuration exactly. Joining an 8.0 meter extension cable to a 1.0 meter probe forms the standard 9.0 meter tuned loop needed to validate factory eddy-current probe scaling.\u003c\/p\u003e\n\u003cp\u003eQ: What physical protection layer does the FluidLoc option (24) provide over standard cables?\u003c\/p\u003e\n\u003cp\u003eA: The FluidLoc cable configuration uses a specialized internal sealing structure that prevents moisture, oil, or chemical contaminants from migrating through the core of the cable by capillary action. This blocks moisture intrusion from reaching the internal terminals even if the outer protective sheath is compromised.\u003c\/p\u003e\n\u003cp\u003eQ: Does installing this cable require manual field loop calibration or component matching?\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 XL series components are engineered for complete interchangeability. As long as the correct 9.0 meter system configuration length is maintained, the hardware eliminates the need for manual bench calibration or component matching during field replacement.\u003c\/p\u003e\n\u003ch3\u003eField Interfacing Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Joint Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClean the miniature coaxial ClickLoc interfaces before locking them together. Once engaged, pull the clear insulation sleeve completely over the junction to eliminate structural frame ground paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Routing Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the cable along the internal machine brackets ensuring the layout does not bend past a minimum radius of 25.4 mm (1.0 inch) to prevent structural damage to the inner conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Constraints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGround the outer instrumentation shielding layer at the monitor rack panel terminal strip only. Let the field end of the shield float to prevent ground loop currents from destabilizing gap voltage validation tracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Routing Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRun the extension cable inside a dedicated, isolated conduit system. Avoid running the high-frequency sensor signal line parallel to high-voltage power lines or variable speed drive output lines to maintain cross-talk suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Check Elements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Line Components:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne Bently Nevada 330854-080-24-CN 8.0 meter FluidLoc extension cable, silicone connector protection sleeves, and physical registration paperwork.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparated Optional Additions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity probe sensors, DIN-rail mounting base plates, and silicon environmental sealing boots must be ordered as distinct lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Configurations and Logistics Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurnaround Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivery time: 2-7 days when payment finish, routed internationally via prioritized express transit channels including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStructural Protection Profiling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSealed in heavy-duty anti-static industrial packaging and shipped inside protective, padded compartments to prevent kinking or stress fractures along the 8.0 meter coaxial path during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026887692461,"sku":"330854-080-24-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-080-25-00-extension-cable-jlp2hkctwb0.jpg?v=1766979472"},{"product_id":"330851-02-000-070-90-00-05-bently-nevada-proximity-probe-3300-xl-series","title":"330851-02-000-070-90-00-05 Bently Nevada Proximity Probe 3300 XL Series","description":"\u003cp\u003eConfigured for non-contact displacement sensing in Turbine Supervisory Instrumentation (TSI) systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330851-02-000-070-90-00-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution. Equipped with an oversized 25 mm sensor head, the hardware measures high-range dynamic thrust position or differential expansion parameters by generating a high-frequency magnetic field to interact with the target machine surface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Array Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBase Model (330851):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm Proximity Probe hardware platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Case Type (02):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eM30 x 2 threaded housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnthreaded Length (000):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 mm unthreaded section.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Case Length (070):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e70 mm fully threaded case body.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Length (90):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.0 meters (29.5 feet) integral cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmor Option (00):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo Armor standard coaxial insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval (05):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple Approvals for hazardous area classifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-02-000-070-90-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 x 22.5 x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive inductive load driven by external 3300 XL Proximitor circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM30 x 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal System Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (29.5 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnarmored coaxial jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 25 mm sensor tip relies on specialized eddy-current probe scaling to achieve an extended linear measurement range far exceeding standard 8 mm variants, making it optimal for long-stroke differential expansion profiles. Field integration requires strict gap voltage validation to anchor the stationary measurement center point inside the linear calibration boundary. The internal coil matrices are engineered for enhanced cross-talk suppression, preventing inductive signal distortion when multiple high-diameter 25 mm probes are positioned adjacent to each other to track high-amplitude rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Mechanical FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Why does this probe omit an unthreaded section (0 mm option) on the M30 x 2 case?\u003c\/p\u003e\n\u003cp\u003eA: The 0 mm unthreaded configuration allows the M30 x 2 threads to extend completely to the base of the 25 mm tip. This allows maximum mechanical flexibility when screwing the probe into through-wall machine cases or thick bracket structures, ensuring complete structural stability.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 9.0 meter integral cable probe be paired with an independent 9.0 meter extension cable?\u003c\/p\u003e\n\u003cp\u003eA: No. The driver electronics are calibrated for a total loop length of 9.0 meters. Because this probe features a native 9.0 meter cable, it must connect directly to the 9.0 meter Proximitor sensor without any mid-loop extension cables. Adding an extra cable will invalidate the factory eddy-current probe scaling.\u003c\/p\u003e\n\u003cp\u003eQ: How does operating near the +177 deg C temperature limit affect the transducive element?\u003c\/p\u003e\n\u003cp\u003eA: The high-temperature potting material and inner winding elements of the 330851 platform are rated for continuous execution up to +177 deg C. Operating within this limit will not cause thermal scale shift or degrade the cross-talk suppression characteristics.\u003c\/p\u003e\n\u003ch3\u003eField Layout Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Thread Engagement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure at least 5 full threads of the M30 x 2 casing are engaged into the mounting plate before locking to counter continuous mechanical frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSide Space Boundaries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDue to the large diameter of the 25 mm tip, maintain a clear radial distance from adjacent structural metal surfaces to prevent side-viewing interference from disrupting the sensor calibration fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Insulation Booting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSnap the miniature coaxial connector firmly into the Proximitor link port and slide the clear insulation boot over the union to prevent the outer shield path from contacting the local machine housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Routing Paths:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the unarmored cable along non-moving internal machine structures using oil-resistant clamps, observing a minimum bend radius of 25.4 mm (1.0 inch) to protect the internal conductor from shearing stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComponents Included\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Line Items:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne Bently Nevada 330851-02-000-070-90-00-05 25 mm proximity probe, integrated M30 x 2 mounting nuts, and a clear connector protection boot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExcluded System Elements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMatching external 3300 XL Proximitor sensors, calibration blocks, and weatherproof industrial junction boxes must be purchased as separate hardware components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Dispatch and Packing Profile\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransit Turnaround Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivery time: 2-7 days when payment finish, routed internationally via premium express networks including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging Specification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped inside heavy-duty anti-static industrial packaging featuring custom-molded interior compartments to secure the 25 mm tip assembly and coiled 9.0 meter unarmored lead against kinetic forces during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026887889069,"sku":"330851-02-000-070-90-00-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-02-000-60-10-00-05-3300-xl-25-mm-proximity-probe-lckx2luutoq.jpg?v=1766981004"},{"product_id":"330850-90-00-bently-nevada-3300-xl-series-proximitor-sensor","title":"330850-90-00 Bently Nevada 3300 XL Series Proximitor Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330850-90-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3300 XL 25 mm Proximitor Sensor\u003c\/strong\u003e, operates as a dedicated eddy-current signal conditioning interface for converting probe gap variation into linear displacement voltage within the 3300 XL transducer system. It processes raw proximity probe input and outputs a calibrated signal proportional to shaft radial movement.\u003c\/p\u003e\n\u003ch3\u003eSuffix \/ Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90: 9.0 m system length configuration\u003c\/li\u003e\n\u003cli\u003e00: No agency approval configuration\u003c\/li\u003e\n\u003cli\u003eMounting: panel mount architecture\u003c\/li\u003e\n\u003cli\u003eSensor family: 3300 XL 25 mm proximitor platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330850-90-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6.2 x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (system loop powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e9.0 m (29.5 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Displacement Processing (Bently Nevada TSI Characteristics)\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 25 mm proximitor system operates through eddy-current field interaction between probe tip and conductive target surface. Displacement of the rotor alters coil impedance, which is converted into a linear voltage output proportional to shaft movement. The system maintains a nominal scale factor of 0.787 V\/mm across its defined linear range of 12.7 mm. Signal stability depends on controlled impedance matching across probe, extension cable, and proximitor interface. Cross-talk suppression is implemented through shielding design and grounding architecture to reduce interference in multi-channel monitoring environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the function of the 330850-90-00 module?\u003cbr\u003eA: It conditions eddy-current probe signals into proportional voltage for displacement and vibration measurement.\u003c\/p\u003e\n\u003cp\u003eQ: Is the system hot-swappable?\u003cbr\u003eA: The proximitor module is not designed for live insertion; system power isolation is required before replacement.\u003c\/p\u003e\n\u003cp\u003eQ: What determines measurement linear range?\u003cbr\u003eA: The 25 mm probe system defines a nominal linear range of 12.7 mm based on scale factor behavior.\u003c\/p\u003e\n\u003cp\u003eQ: Does cable length affect signal accuracy?\u003cbr\u003eA: The 9.0 m system length is factory defined and must be maintained to preserve calibration integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall panel-mounted unit on grounded metallic enclosure surface\u003c\/li\u003e\n\u003cli\u003eMaintain separation between signal cables and high-voltage conductors\u003c\/li\u003e\n\u003cli\u003eEnsure full seating of connectors to avoid impedance mismatch\u003c\/li\u003e\n\u003cli\u003eVerify probe and extension cable continuity before energization\u003c\/li\u003e\n\u003cli\u003eUse proper shielding termination at single grounding point\u003c\/li\u003e\n\u003cli\u003eAvoid mechanical stress on coaxial cable routing paths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 330850-90-00 25 mm Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003eFactory configured 9.0 m system length assembly\u003c\/li\u003e\n\u003cli\u003ePanel mounting hardware included\u003c\/li\u003e\n\u003cli\u003eNo calibration accessories included unless specified\u003c\/li\u003e\n\u003cli\u003eA380 aluminum housing assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days after payment confirmation or 2-7 days depending on logistics route. Shipment via DHL \/ FedEx \/ UPS with anti-static industrial packaging, shock-resistant sealing, and vibration-protected handling for precision monitoring electronics.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026896146605,"sku":"330850-90-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330850-90-00_1.jpg?v=1779959720"},{"product_id":"bently-nevada-3300-system-330850-90-05-proximity-sensor","title":"Bently Nevada 3300 System 330850-90-05 Proximity Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330850-90-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3300 XL 25 mm Proximitor Sensor\u003c\/strong\u003e, operates as a dedicated hardware interface for converting eddy-current probe displacement signals into conditioned voltage output within the 3300 monitoring system. It processes raw probe gap variation into a calibrated electrical signal proportional to shaft radial position.\u003c\/p\u003e\n\u003ch3\u003eSuffix \/ Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90: 9.0 m system length cable assembly\u003c\/li\u003e\n\u003cli\u003e05: Multiple agency approvals configuration\u003c\/li\u003e\n\u003cli\u003ePanel mount: Fixed installation interface\u003c\/li\u003e\n\u003cli\u003eSensor family: 3300 XL 25 mm Proximitor architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330850-90-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 6 x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot explicitly specified (system loop powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e9.0 m (29.5 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Scale Factor\u003c\/td\u003e\n\u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current probe interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Displacement Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL proximity system uses eddy-current field interaction between probe tip and conductive target surface to derive displacement data. The proximitor converts probe coil impedance variation into a linearized voltage output referenced to calibrated gap conditions. Scale factor stability at 0.787 V\/mm is maintained across the specified temperature range. Signal integrity is dependent on cross-talk suppression between adjacent channels and stable gap voltage validation near nominal -10 VDC operating reference behavior in associated probe driver circuitry.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 330850-90-05 support 3300 XL probe interchangeability?\u003cbr\u003eA: It is designed for compatibility with 3300 XL 25 mm proximity probe systems within defined calibration ranges.\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of the 9.0 m system length specification?\u003cbr\u003eA: It defines the maximum integrated cable distance between probe, extension cable, and proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ: Can the sensor operate under high-temperature conditions continuously?\u003cbr\u003eA: The module is rated for operation up to +100 deg C with defined thermal drift characteristics.\u003c\/p\u003e\n\u003cp\u003eQ: Does the system require external calibration after installation?\u003cbr\u003eA: Calibration is factory-set; field verification may be performed using standard gap reference targets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall panel-mounted proximitor on stable grounded metal surface\u003c\/li\u003e\n\u003cli\u003eMaintain separation between probe cable and high-voltage conductors\u003c\/li\u003e\n\u003cli\u003eEnsure probe tip alignment perpendicular to rotating shaft surface\u003c\/li\u003e\n\u003cli\u003eVerify extension cable shielding continuity and grounding integrity\u003c\/li\u003e\n\u003cli\u003eAvoid mechanical stress on connector interface during installation\u003c\/li\u003e\n\u003cli\u003eConfirm system length configuration matches 9.0 m assembly specification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 330850-90-05 Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003ePanel mount hardware configuration\u003c\/li\u003e\n\u003cli\u003eFactory cable assembly (9.0 m system length)\u003c\/li\u003e\n\u003cli\u003eMultiple approvals variant labeling included\u003c\/li\u003e\n\u003cli\u003eNo calibration accessories included unless specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days after payment confirmation or 2-7 days depending on carrier routing. Shipment via DHL \/ FedEx \/ UPS with anti-static industrial-grade packaging designed for vibration monitoring instrumentation and precision analog signal modules.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026900537517,"sku":"330850-90-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330850-90-05_3.jpg?v=1779958712"}],"url":"https:\/\/www.maxwellplc.com\/ru\/collections\/bently-nevada-3300xl-25mm-50mm-probes-differential-expansion.oembed?page=3","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}