{"title":"Allen-Bradley Distributed I\/O (FLEX\/POINT)","description":"\u003cp\u003e\u003cspan\u003eReduce wiring costs and cabinet space with Allen-Bradley’s distributed I\/O solutions. Our catalog features the highly flexible \u003c\/span\u003e\u003cstrong\u003e1794\/1797 FLEX I\/O\u003c\/strong\u003e\u003cspan\u003e, designed for high-density modularity, and the space-saving \u003c\/span\u003e\u003cstrong\u003e1734 POINT I\/O\u003c\/strong\u003e\u003cspan\u003e for smaller, localized control. These modules allow you to place your inputs and outputs closer to the sensors and actuators, communicating back to the main controller via EtherNet\/IP, ControlNet, or PROFIBUS. Whether you need digital, analog, or specialty safety modules, we provide the modular components necessary for a distributed, scalable network architecture.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1797-ob4d-4-point-digital-output-module","title":"Allen-Bradley 1797-OB4D 4-Point Digital Output Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1797-OB4D is a specialized four-channel digital sourcing output module designed for the FLEX™ Ex I\/O system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered specifically for hazardous area applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis intrinsically safe module allows for the direct control of field devices—such as solenoid valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esmall actuators,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand motor starters—located in potentially explosive environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing a sourcing output architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module simplifies field wiring by referencing all four channels to a single common power supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eAs part of the FLEX Ex family,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1797-OB4D provides a modular and space-efficient solution that eliminates the need for bulky isolation barriers.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt integrates seamlessly into the FLEX I\/O backplane,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding high-speed communication and advanced diagnostic capabilities that ensure process safety and maximized uptime in critical industrial sectors like oil and gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echemical processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand mining.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Configuration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 sourcing digital output channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eArchitecture:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNon-isolated sourcing type with a shared common supply for streamlined wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntrinsically Safe Design:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically rated for use with FLEX Ex terminal bases in hazardous locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSmart Diagnostics:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel detection for wire-break (open circuit) and short-circuit faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVisual Indicators:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a dedicated red\/green status LED and four yellow channel-state LEDs for immediate on-site troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResponse Performance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed data refresh rate of 2 milliseconds from the system backplane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eElectronic Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated protection circuits prevent module damage during field-side electrical faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDIN-rail mountable via compatible FLEX Ex terminal bases (e.\u003c\/span\u003e\u003cspan class=\"\"\u003eg.,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1797-TB3 or 1797-TB3S).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for industrial-grade thermal resilience (0°C to 60°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e9 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eAdvanced Fault Detection and Hazardous Area Control\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1797-OB4D stands out due to its \"D\" (Diagnostic) designation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich provides granular feedback to the controller.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1797-OB4D can differentiate between a healthy load and a disconnected wire.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen a fault is detected,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe status LED provides a flashing red signal,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing maintenance personnel to pinpoint the failure location without exhaustive manual testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis module is optimized for use with ControlLogix® or SLC 500™ systems via a FLEX Ex adapter.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts low-power,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eintrinsically safe design significantly reduces the thermal footprint within the control enclosure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhile the ruggedized housing protects internal electronics from the vibration and humidity common in remote field locations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy providing deterministic control and real-time health monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1797-OB4D ensures that critical automated sequences—such as emergency shutdowns or precise dosing—are executed with total reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519092482221,"sku":"1797-OB4D","price":899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1797-ob4d-flex-ex-output-module-kznbkmxfyvz.jpg?v=1766986838"},{"product_id":"1794-adn-allen-bradley-24v-dc-devicenet-communication-head","title":"1794-ADN Allen-Bradley 24V DC DeviceNet Communication Head","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-2225 citation-end-2225\"\u003eThe Allen-Bradley 1794-ADN serves as a high-performance communication gateway for the FLEX™ I\/O system, enabling seamless integration into DeviceNet® industrial networks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis adapter module acts as the localized head-end for a distributed I\/O rack, managing the data exchange between the central PLC processor and up to eight individual FLEX I\/O expansion modules. By centralizing power distribution and network signals, the 1794-ADN reduces wiring complexity and allows for modular scalability in modern automation environments.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for high availability, the 1794-ADN effectively bridges the gap between field-level sensors and supervisory control systems.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-2224 citation-end-2224\"\u003eIts compact, open-type design supports both standard DIN rail and panel mounting, making it an ideal choice for space-constrained control cabinets in manufacturing, material handling, and process industries.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eConnectivity and Network Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1794-ADN is engineered to provide a stable and deterministic link for mission-critical data.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-2223\"\u003e\u003c\/span\u003e\u003cstrong\u003eMulti-Rate Communication:\u003c\/strong\u003e\u003cspan class=\"citation-2223 citation-end-2223\"\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically detects and supports standard DeviceNet transmission speeds of 125 Kbps, 250 Kbps, and 500 Kbps upon power-up.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Addressing:\u003c\/strong\u003e\u003cspan class=\"citation-2222 citation-end-2222\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures integrated manual thumbwheel switches for quick node address assignment (ranging from 00 to 63), eliminating the need for complex software configuration during initial hardware setup.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Power Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on a nominal 24V DC input and provides a dedicated 640 mA FlexBus output to power the internal logic of the attached I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Transparency:\u003c\/strong\u003e\u003cspan class=\"citation-2221 citation-end-2221\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with front-panel LED indicators that provide real-time status updates for \"Module Status,\" \"Network Status,\" and \"I\/O Status,\" facilitating rapid troubleshooting.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-2220\"\u003e\u003c\/span\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"citation-2220 citation-end-2220\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1794-ADN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDeviceNet Communication Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (Range: 19.2–31.2V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-2219\"\u003e\u003c\/span\u003e\u003cstrong\u003eNetwork Protocol:\u003c\/strong\u003e\u003cspan class=\"citation-2219 citation-end-2219\"\u003e\u003cspan\u003e \u003c\/span\u003eDeviceNet (CAN-based)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 8 FLEX I\/O Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexBus Output Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e640 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeviceNet Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-2218\"\u003e\u003c\/span\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"citation-2218 citation-end-2218\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +70°C (-4°F to 158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.4 x 9.1 x 8.6 cm (3.7 x 3.6 x 3.4 inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.9 kg (1.98 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Durability and Environmental Compliance\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for operation in harsh industrial zones, with significant resistance to operational shock and vibration to ensure continuous network uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIts small footprint allows for high-density I\/O configurations, compatible with standard 35mm DIN rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for use with standard 5-pin or 10-pin linear DeviceNet plugs; Rockwell recommends high-quality industrial-grade cabling (like Belden YR-29832) to maintain signal integrity over long trunk lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes internal polarity protection for the 24V DC input and isolation between the DeviceNet network and the local I\/O logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519093563565,"sku":"1794-ADN","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-adn-devicenet-adaptor-bbh55k12utw.jpg?v=1766986884"},{"product_id":"allen-bradley-1797-acnr15-flex-ex-i-o-modules","title":"Allen-Bradley 1797-ACNR15 FLEX Ex I\/O Modules","description":"\u003ch3 class=\"\"\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1797-ACNR15 is a high-performance ControlNet communication adapter designed specifically for the FLEX™ Ex I\/O system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module functions as a critical gateway between a ControlNet network and intrinsically safe I\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for distributed control in Zone 1,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eZone 2,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Class I,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDivision 1 hazardous environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating intrinsic safety (IS) protection directly into the communication architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1797-ACNR15 eliminates the need for expensive explosion-proof enclosures or external purges in many volatile industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe \"R\" designation in the model number signifies its support for redundant media.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with dual BNC coaxial connectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module maintains simultaneous communication across two independent cables.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis dual-path architecture ensures that a single cable failure or signal interruption does not result in system downtime,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it indispensable for continuous process industries where operational continuity is vital for safety and productivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eIntrinsically Safe Networking and Performance\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1797-ACNR15 is engineered to meet the most rigorous global standards for hazardous area operation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding ATEX,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIECEx,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand UL certifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Communication:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual ControlNet ports provide automatic seamless switchover between Media A and Media B,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring high-availability data transmission.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Speed Throughput:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports a deterministic 5 Mbps communication rate,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the rapid response times required for complex safety and process loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExpansion Scalability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA single adapter acts as the bus head-end for up to eight FLEX Ex I\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecentralizing the interface for various analog and digital field signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Diagnostics:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eLocalized LED arrays provide real-time status for the module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epower supply,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand individual network channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating rapid fault isolation in the field.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSimplified Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCommunicates over standard ControlNet coax,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing intrinsically safe I\/O clusters to be integrated into broader plant-wide ControlLogix® or PLC-5® systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1797-ACNR15\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFLEX Ex ControlNet Redundant Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (Intrinsically Safe Power)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Protocol:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eControlNet (Coax)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Rate:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5 Mbps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eI\/O Module Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 8 modules per adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Watts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +70°C (-4°F to 158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHazardous Area Rating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eClass I Div 1; Zone 1 (Intrinsic Safety)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e9 kg (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e98 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eHazardous Area Application\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1797-ACNR15 is the preferred solution for sectors where flammable gases,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evapors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor liquids are present:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOil and Gas:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRemote monitoring of wellhead sensors and valve control on offshore platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChemical Processing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eData acquisition from distillation columns and reactor monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePharmaceutical:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePrecision control of volatile chemical mixing and batching processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePaint and Coating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eManaging automation in spray booths and solvent storage facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519094841517,"sku":"1797-ACNR15","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1797-acnr15-flex-ex-i-o-modules-wc3sroezock.jpg?v=1766986933"},{"product_id":"1794-ie8-allen-bradley-flex-i-o-8-channel-analog-input-module","title":"1794-IE8 Allen-Bradley FLEX I\/O 8-Channel Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1794-IE8 is a high-performance 8-point analog input module designed for the FLEX™ I\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module serves as a versatile interface for converting real-world analog signals from field transmitters into digital data for PLC processing.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt supports a wide array of signal configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding standard 4-20mA and 0-20mA current loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eas well as 0-10V DC and ±10V DC voltage ranges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eBy utilizing a modular design,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-IE8 attaches to a separate terminal base (such as the 1794-TB2 or 1794-TB3),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich centralizes field wiring and allows for Removal and Insertion Under Power (RIUP).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis feature is critical for industrial environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling hardware maintenance or replacement without interrupting system power or disturbing existing terminations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eAdvanced Signal Processing and Performance\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IE8 is engineered to deliver high-speed data acquisition with consistent thermal stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePrecision Conversion:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEmploys a successive approximation converter providing 12-bit unipolar resolution and 11-bit plus sign bipolar resolution for accurate signal representation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Speed Sampling:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a rapid conversion rate of 256μs for all channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring minimal latency in dynamic process control loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFlexible Input Selection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSoftware-configurable channels allow for a mix of voltage and current inputs to suit diverse sensor types.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRugged Reliability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to operate in temperatures ranging from -20°C to 55°C and designed to withstand up to 5g of vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it suitable for mounting directly on machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDistributed Architecture:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSeamlessly connects to EtherNet\/IP,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eControlNet,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor DeviceNet networks via FLEX I\/O adapters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereducing the need for long,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eexpensive home-run cable pulls.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-IE8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8 Single-ended\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Ranges:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e±10V DC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0-10V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12 bits (Unipolar); 11 bits + sign (Bipolar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAccuracy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e20% Full Scale @ 25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExternal DC Power:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC nominal (Range 10.\u003c\/span\u003e\u003cspan class=\"\"\u003e5-31.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e20mA @ 5V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Impedance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e238 ohms (Current); 100k ohms (Voltage)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e12 kg (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e26 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IE8 is a key component in the Rockwell Automation distributed I\/O family.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module must be aligned with the Position 3 keyswitch on the terminal base to ensure correct mechanical and electrical mating.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts compact profile and DIN-rail mounting capability make it an ideal choice for high-density control cabinets where space is a premium.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eFor specialized environments where humidity or chemical exposure is a concern,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econformal-coated versions of the 1794-IE8 are available to provide enhanced protection for the internal circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519095136429,"sku":"1794-IE8","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-ie8-flex-8-point-analog-input-module-d3lvulqdchg.jpg?v=1766986949"},{"product_id":"1794-aentrxt-allen-bradley-flex-i-o-dual-port-ethernet-ip-xt-adapter","title":"1794-AENTRXT Allen-Bradley FLEX I\/O Dual-Port EtherNet\/IP XT Adapter","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1794-AENTRXT is an \"Extended Duty\" (XT) communication interface designed for the FLEX™ I\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module serves as a high-performance bridge between EtherNet\/IP networks and distributed I\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for seamless data exchange with programmable logic controllers (PLCs).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe \"XT\" designation signifies its specialized engineering for extreme environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing a conformal coating to protect against corrosive atmospheres and an expanded thermal operating range that exceeds standard industrial hardware limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eEquipped with dual Ethernet ports,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-AENTRXT supports Device Level Ring (DLR) topologies,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich provide critical network redundancy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a cable break,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe DLR capability ensures that communication remains active,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eminimizing system downtime.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis adapter is the ideal choice for distributed control systems in offshore rigs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewastewater treatment plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand remote pump stations where reliability is non-negotiable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Capabilities and Network Resiliency\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-AENTRXT is optimized for high-speed connectivity and environmental protection in hazardous or remote locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDual-Port Redundancy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports DLR (Device Level Ring),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eLinear,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Star network topologies to ensure continuous operation during single-point network failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExtended Thermal Performance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRated for reliable operation in temperatures ranging from -20°C to +70°C (-4°F to +158°F).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChemical Resistance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFactory-applied conformal coating meets ISA\/ANSI-71.\u003c\/span\u003e\u003cspan class=\"\"\u003e040-1985 G3 standards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a barrier against noxious gases and high humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Speed Processing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDelivers 10\/100 Mbps communication rates with full-duplex support for low-latency I\/O updates.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Power Regulation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEfficiently converts a 24V DC input into the 5V DC backplane power required to drive up to eight attached FLEX I\/O modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-AENTRXT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEtherNet\/IP Network Adapter (Extended Duty)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePorts:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2 x RJ45 EtherNet\/IP (DLR Capable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Speed:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10\/100 Mbps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 8 FLEX I\/O modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (19.\u003c\/span\u003e\u003cspan class=\"\"\u003e2–31.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNominal Input Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e450mA @ 24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e7.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 Watts (maximum)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHazardous Area Rating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNorth American Class I Div 2 \/ ATEX Zone 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 x 8.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 x 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e18 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eApplication and System Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-AENTRXT is specifically utilized in industries requiring \"Extreme Environment\" (XT) certified hardware:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOil \u0026amp; Gas Production:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring wellheads and separators in high-temperature,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecorrosive environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMining Operations:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding distributed I\/O for processing equipment exposed to dust and vibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWater\/Wastewater:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eManaging remote lift stations and chemical dosing systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGlobal Logistics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperating in non-climate-controlled warehouses and outdoor terminal cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519095627949,"sku":"1794-AENTRXT","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-aentrxt-network-adapter-3kpxc31hdbr.jpg?v=1766986967"},{"product_id":"1794-ie12-allen-bradley-flex-i-o-12-channel-high-density-analog-input-module","title":"1794-IE12 Allen-Bradley FLEX I\/O 12-Channel High-Density Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1794-IE12 is a high-density analog input expansion module engineered for the FLEX™ I\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt provides twelve non-isolated input channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for the simultaneous monitoring of multiple process variables within a single,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003espace-saving footprint.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is designed to bridge field sensors and programmable controllers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econverting diverse signal types—including 4-20mA current loops and ±10V DC voltage inputs—into 16-bit digital values for high-precision control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDesigned for distributed I\/O architectures,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-IE12 mounts onto a standard terminal base,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich facilitates \"Removal and Insertion Under Power\" (RIUP).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis capability allows maintenance teams to replace the module without disconnecting field wiring or shutting down the entire system,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring maximum process uptime.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module’s high channel count makes it an ideal choice for data-intensive applications such as environmental monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echemical processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand complex assembly lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSignal Processing and Precision\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IE12 utilizes advanced Successive Approximation (SAR) technology to deliver superior signal fidelity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e16-Bit Resolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOffers granular data capture with a resolution of 320 μV per count for voltage signals and 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e641 μA per count for current measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndependently Configurable Channels:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 12 ports can be tailored to match the specific requirements of the connected field device,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting 0-20mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4-20mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand ±10V DC ranges.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Speed Conversion:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a standard conversion rate of 8.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 ms for all channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith an optimized Quick Step mode for faster response in dynamic monitoring scenarios.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExceptional Accuracy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMaintains a 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e1% full-scale accuracy at 25°C,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the reliability required for critical process loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRugged Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in circuitry protects against continuous input overloads up to 30V,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esafeguarding the internal electronics from field wiring errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-IE12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12 Channels (Single-ended,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enon-isolated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Ranges:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4–20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0–20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e±10V DC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0–10V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 Bits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e20mA @ 5V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExternal DC Power:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC nominal (Range 10.\u003c\/span\u003e\u003cspan class=\"\"\u003e5–31.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Impedance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e238 ohms (Current),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e100k ohms (Voltage)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMechanical Rating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e30g Operational Shock; 5g Vibration (10–500 Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm (Logic Component)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e9 kg (Approx.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e98 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eInstallation and System Compatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IE12 integrates seamlessly into the Rockwell Automation ecosystem via various FLEX I\/O adapters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting EtherNet\/IP,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eControlNet,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand DeviceNet communication protocols.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt requires a compatible terminal base,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as the 1794-TB3G or 1794-TB3GS,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich uses a specific Position 3 keyswitch alignment to ensure correct mechanical seating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDue to its high-density design and robust environmental ratings,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module is widely utilized in the oil and gas sector,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewater treatment facilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand power generation plants where reliable analog data acquisition is mandatory in harsh conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519095890093,"sku":"1794-IE12","price":369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-ie12-analog-input-module-3kxhhzrfecq.jpg?v=1766986980"},{"product_id":"1794-ir8-allen-bradley-flex-i-o-8-channel-rtd-temperature-input-module","title":"1794-IR8 Allen-Bradley FLEX I\/O 8-Channel RTD Temperature Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1794-IR8 is a high-density,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8-channel analog input module designed for precision temperature sensing within the FLEX™ I\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module converts resistance signals from Resistance Temperature Detectors (RTDs) or direct ohm inputs into digital data for a programmable controller.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for versatility,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit supports a broad range of industrial RTD standards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding Platinum,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNickel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCopper,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Nickel-Iron sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IR8 is an ideal solution for process industries that require localized temperature monitoring without the need for extensive long-distance sensor wiring.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt integrates seamlessly onto a 1794 terminal base (such as the 1794-TB3 or 1794-TB3S),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a compact footprint for DIN-rail or panel-mounted applications.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith 16-bit resolution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module is specifically tailored for critical temperature control loops in chemical processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethermal management,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand pharmaceutical manufacturing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eAdvanced Measurement and Noise Immunity\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IR8 is optimized for stable operation in electrically \"noisy\" factory environments where electromagnetic interference can compromise signal integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Resolution Digitization:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a 16-bit Sigma-Delta converter to ensure granular data capture across the entire input range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Noise Rejection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a sophisticated digital filter providing 60dB of common-mode rejection at 60Hz,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeffectively neutralizing AC line interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDual Operating Modes:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOffers a \"Normal Mode\" for standard high-speed updates and an \"Enhanced Mode\" for maximum precision,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eachieving an accuracy rating as fine as 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e01% of full scale.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSensor Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAccommodates multiple standards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding 100Ω Platinum (Alpha 385 and 3916),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e120Ω Nickel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand 10Ω Copper sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFlexible Scaling:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports a wide resistance input range from 1 to 433 ohms,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing it to be used for specialized potentiometer or resistive position sensing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-IR8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels (Non-isolated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16-bit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExcitation Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e718.\u003c\/span\u003e\u003cspan class=\"\"\u003e36 µA (typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e707V DC (Continuous)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eData Format:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16-bit 2's Complement or Binary\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThroughput Rate:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable from 28ms to 650ms (for all 8 channels)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Requirements:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC nominal (10.\u003c\/span\u003e\u003cspan class=\"\"\u003e0V–31.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e20mA @ 5V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 9.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e15 kg (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e33 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eSystem Reliability and Safety Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntelligent Diagnostics:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides real-time detection for open-circuit (sensor break) or short-circuit conditions,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003einstantly notifying the controller to trigger safety interlocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOvervoltage Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to withstand continuous overvoltages of up to 35V DC or 25V AC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreventing hardware failure during field wiring faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCalibration-Free Design:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eComes factory-calibrated to maintain long-term stability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereducing the need for periodic field maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExtended Thermal Stability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompensates for cold-junction and ambient drift across a wide operating temperature range of -20°C to +55°C (-4°F to +131°F).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519097987245,"sku":"1794-IR8","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-ir8-rtd-input-module-lzmt3jrjopf.jpg?v=1766987038"},{"product_id":"1797-ie8-allen-bradley-flex-ex-8-channel-intrinsically-safe-analog-input-module","title":"1797-IE8 Allen-Bradley FLEX Ex 8-Channel Intrinsically Safe Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1797-IE8 is a high-precision,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8-channel analog current input module specifically engineered for the FLEX Ex™ I\/O system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is designed to interface with field devices located in hazardous areas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding intrinsic safety (IS) protection without the need for external barriers.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating the IS barrier functionality directly into the module hardware,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1797-IE8 simplifies cabinet architecture while ensuring compliance with stringent explosive atmosphere standards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding Ex ia and Class I,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDivision 1.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eSupporting standard 4-20 mA current loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1797-IE8 converts analog process variables into high-resolution 16-bit digital data.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is a critical component for oil and gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echemical processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand pharmaceutical applications where flammable gases or vapors are present and measurement accuracy is paramount for process safety and efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHigh-Resolution Measurement and Safety Architecture\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1797-IE8 combines laboratory-grade measurement precision with ruggedized hardware for volatile environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntrinsically Safe Design:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEliminates the risk of electrical sparking by limiting the energy available to the hazardous area,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecertified for use in Zone 1 and Zone 2 (ATEX\/IECEx) as well as North American Class I,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eII,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand III locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e16-Bit Resolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides highly granular data conversion for precise monitoring of pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eflow,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand level sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting an accuracy of 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e1% of full scale.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNon-Isolated Channels:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures eight high-speed current inputs sharing a common return,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for high-density sensor arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConfigurable Input Filtering:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllows users to adjust the software-selectable digital filter to mitigate the effects of industrial noise and signal transients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStandardized Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMounts onto specialized 1797-TB3 or 1797-TB3S terminal bases,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating \"Removal and Insertion Under Power\" (RIUP) even in hazardous zones when appropriate safety protocols are followed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1797-IE8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Current (4-20 mA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels (Non-isolated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 bits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntrinsic Safety Rating:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEx ia IIC T4,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eClass I Div 1 Groups A-D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Impedance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 65 ohms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAccuracy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e1% Full Scale @ 25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Consumption:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 Watts @ 9V DC (from FlexBus)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e13.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 BTU\/hr\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 70°C (-4°F to 158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e9 kg (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e98 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eDiagnostic Monitoring and Maintenance\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1797-IE8 includes advanced firmware-based diagnostics that continuously monitor the integrity of the field wiring and the health of the module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWire-Break Detection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInstantly identifies open-circuit conditions in the 4-20 mA loop,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing the controller to trigger \"fail-safe\" states.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRange Validation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDetects and flags over-range and under-range signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eidentifying potential sensor calibration drift or mechanical failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLED Status Array:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel indicators provide local visual confirmation of module power,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecommunication status,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand individual channel faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProactive Troubleshooting:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDiagnostic data is transmitted via the FLEX Ex adapter to the central PLC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling remote monitoring of field-side health without entering the hazardous area.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519098314925,"sku":"1797-IE8","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1797-ie8-analog-input-module-30m2otgbgzb.jpg?v=1766987050"},{"product_id":"1794-oe12-allen-bradley-12-channel-analog-output-module","title":"1794-OE12 Allen-Bradley 12-Channel Analog Output Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1794-OE12 is a high-density expansion module designed for the FLEX™ I\/O platform,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding twelve independent analog output channels in a single,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003espace-efficient footprint.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is engineered to convert digital values from the controller into precise analog signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling the control of a wide variety of field devices such as proportional valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evariable speed drives,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand industrial actuators.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting both voltage and current output modes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-OE12 offers the versatility required for complex process control and manufacturing automation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe module utilizes a 16-bit digital-to-analog converter (DAC) to deliver exceptional signal resolution and accuracy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis high-resolution performance allows for granular control adjustments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich is critical for maintaining stability in sensitive control loops.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs part of the distributed FLEX I\/O family,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit connects to a variety of network adapters—including EtherNet\/IP,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eControlNet,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand PROFIBUS—allowing for flexible placement near the field devices to reduce wiring costs and minimize signal interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eAdvanced Signal Performance and Precision\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-OE12 is built to maintain high accuracy across its entire operating range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that command signals remain consistent despite industrial environmental fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDual-Mode Outputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEach channel is individually configurable to provide either current (0–20mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4–20mA) or voltage (±10V DC) signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSuperior Resolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDelivers precision counts of 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e641 μA for current loops and 320 μV for voltage outputs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring smooth transitions for final control elements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Management:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for low power dissipation (7.\u003c\/span\u003e\u003cspan class=\"\"\u003e68W @ 24V DC),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for high-density mounting in enclosures without excessive heat buildup.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eError Prevention:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a keyswitch system (Position 4) on the terminal base to ensure only the correct module type can be inserted into the designated slot,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprotecting the system from wiring mismatches.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-OE12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12 Channels (Single-ended)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDigital-to-Analog Resolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 Bits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Ranges:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0–20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4–20 mA; ±10V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAccuracy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e1% Full Scale @ 25°C (77°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExternal DC Power:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC Nominal (Range:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10.\u003c\/span\u003e\u003cspan class=\"\"\u003e5–31.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMaximum Resistive Load:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e750 Ω (Current Mode)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTerminal Base Requirement:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with 1794-TB32 or 1794-TB32S bases\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVibration\/Shock Resistance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5g vibration; 30g operational shock\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9.4 x 9.4 x 5.3\u003c\/span\u003e\u003cspan class=\"\"\u003e cm (3.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 x 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 x 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 in.\u003c\/span\u003e\u003cspan class=\"\"\u003e)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e9 kg (Shipping weight)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eDistributed Architecture and Reliability\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHot-Swap Capability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports \"Removal and Insertion Under Power\" (RIUP),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing maintenance personnel to replace modules without shutting down the entire system or disconnecting field-side wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCompact Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe high channel count (12 points) significantly reduces the number of modules required for large systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptimizing cabinet rail space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRuggedized Design:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to withstand the mechanical stresses of industrial environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emeeting strict standards for shock and vibration durability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a front-panel LED indicator to provide instant feedback on module power and operational status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519098904749,"sku":"1794-OE12","price":1599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-oe12-analog-output-module-r3isp5l4eqj.jpg?v=1766987077"},{"product_id":"1734-ie4c-allen-bradley-point-i-o-4-channel-analog-input-module","title":"1734-IE4C Allen-Bradley POINT I\/O 4-Channel Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1734-IE4C is a high-density analog input module designed for the POINT I\/O™ platform,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding four high-precision current input channels in a slim,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003espace-saving form factor.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is engineered to interface with field sensors that generate 0 to 20mA or 4 to 20mA signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econverting these continuous physical variables into 16-bit digital values for the controller.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts ultra-compact 12mm width makes it an essential component for distributed I\/O configurations where cabinet space is at a premium.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDesigned for seamless integration into Logix-based architectures via Studio 5000®,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1734-IE4C supports diverse process control applications ranging from chemical processing to wastewater management.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module installs onto a 1734-TB or 1734-TBS wiring base,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for \"Change-of-State\" (COS) data reporting to optimize network bandwidth and ensure high-speed system responsiveness.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1734-IE4C utilizes a Sigma-Delta conversion method to achieve superior noise rejection and measurement stability.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEach of the four channels is independently monitored,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the processor with granular data including over-range and under-range detection.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure long-term reliability in industrial environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module features built-in digital filtering that can be configured to suppress 50Hz or 60Hz line noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eFor maintenance efficiency,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module supports \"Removal and Insertion Under Power\" (RIUP),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing technicians to replace faulty slices without shutting down the entire I\/O segment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVisual diagnostics are provided through a set of LED indicators on the front panel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich communicate module status,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enetwork activity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand individual channel faults at a glance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1734-IE4C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Current (Single-ended)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Signal Ranges:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4–20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0–20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 Bits (0 to 21 mA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e32 µA\/bit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConversion Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSigma-Delta\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStep Response:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e70ms @ 60Hz filter,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e80ms @ 50Hz filter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePOINTBus Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e75 mA @ 5V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 W maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 BTU\/hr maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e50V (continuous),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBasic Insulation Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 x 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm (approximate)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e04 kg (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e088 lb)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Environmental Ratings\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcess Control:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for monitoring pressure transmitters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eflow meters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand temperature transducers in liquid processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHazardous Locations:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCarries North American (Class I,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDiv 2),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEuropean (ATEX),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand IECEx certifications for safe operation in volatile atmospheres.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModular Scalability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEasily integrates with Ethernet\/IP,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDeviceNet,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor ControlNet adapters within the POINT I\/O family.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Density Packaging:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMinimizes the required DIN rail length compared to traditional rack-based PLC I\/O.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519106867373,"sku":"1734-IE4C","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1734-ie4c-point-i-o-4-point-analog-input-module-5uatjrupqiw.jpg?v=1766987203"},{"product_id":"1794-tb3k-allen-bradley-flex-i-o-terminal-base-unit-conformal-coated","title":"1794-TB3K Allen-Bradley FLEX I\/O Terminal Base Unit (Conformal Coated)","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1794-TB3K is a specialized terminal base unit designed for the FLEX I\/O platform,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eserving as the essential mounting and wiring backbone for individual I\/O modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis unit facilitates the electrical connection between field sensors\/actuators and the FLEXbus communication backplane.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA critical feature of the \"K\" variant is its factory-applied conformal coating,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich provides an added layer of protection against moisture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edust,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand corrosive chemical environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it ideal for harsh industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-TB3K utilizes a 3-wire termination style,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering a high-density connection point that simplifies cabinet layout by providing integrated power and common terminals for each I\/O point.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis design eliminates the need for external terminal strips for many applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereducing overall installation time and panel space requirements.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy angling the unit onto a standard DIN rail and engaging the locking mechanism,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eusers create a rigid foundation that supports hot-swapping of I\/O modules without disturbing the field wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eElectrical and Mechanical Interface\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis terminal base is engineered for versatility,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting a wide voltage range up to 125V AC\/DC.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe wiring architecture consists of 16 dedicated I\/O terminals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e18 common terminals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand 18 voltage terminals.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis generous allocation of termination points allows for efficient daisy-chaining of field power to adjacent terminal bases,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estreamlining the power distribution network within the I\/O rack.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe unit features robust screw-clamp terminals designed to accept wire sizes from 24 to 16 AWG.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure long-term electrical stability in high-vibration environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe terminals are rated for a specific torque range of 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e56–0.\u003c\/span\u003e\u003cspan class=\"\"\u003e79 Nm.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFurthermore,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-TB3K provides complete galvanic isolation between the field-side wiring and the logic-side FLEXbus,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprotecting the central PLC processor from field-induced electrical noise or surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-TB3K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduct Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTerminal Base Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConformal Coated (K-Version)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMaximum Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e125V AC\/DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCurrent Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10A Maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTermination Count:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 I\/O,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e18 Common,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e18 Voltage terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWire Gauge Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24–16 AWG stranded copper\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTerminal Torque:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e56–0.\u003c\/span\u003e\u003cspan class=\"\"\u003e79 Nm (5–7 lb-in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +70°C (-4°F to +158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eShock\/Vibration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e30G Functional Shock; 5G Vibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9  x 9  x 7 cm (Standard FLEX footprint)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCertifications:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ec-UL-us,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUL,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCSA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCE,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEx,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMarine\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Reliability and Mounting\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRuggedized Design:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating ensures reliable operation in \"Class G3\" harsh environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreventing dendritic growth and silver corrosion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDIN Rail Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports rapid assembly on standard 35mm DIN rails with integrated grounding and interlocking tabs for adjacent units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSimplified Power Distribution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDedicated voltage and common buses reduce the complexity of wiring auxiliary power to field devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eServiceability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for \"Removal and Insertion Under Power\" (RIUP), enabling module replacement while the rest of the FLEX I\/O system remains operational.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519114076333,"sku":"1794-TB3K","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-tb3k-base-unit-jbccarpp1q0.jpg?v=1766987306"},{"product_id":"allen-bradley-1794-ib16-flex-i-o-16-channel-sink-digital-input-module","title":"Allen-Bradley 1794-IB16 FLEX I\/O 16-Channel Sink Digital Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IB16 is a high-density digital input module from the Allen-Bradley FLEX I\/O™ family,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eengineered to interface field sensors with industrial controllers.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module features 16 non-isolated sink-style inputs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003especifically designed to detect 24V DC discrete signals from devices such as limit switches,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand pushbuttons.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing a modular \"slide-and-plug\" architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-IB16 allows for the maintenance of individual I\/O components without disturbing existing field wiring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reducing system downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eAs a core component of decentralized automation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-IB16 offloads wiring from the main PLC chassis to the machine level.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is compatible with various FLEX I\/O terminal bases and communication adapters (including EtherNet\/IP,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eControlNet,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand DeviceNet),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a scalable solution for high-performance signal handling in both standard and SIL2 safety-rated applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Density:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 Digital Inputs (Sinking configuration).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNominal Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (Input range of 10V DC to 31.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Style:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSink (Current flows from the input device into the module).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOn-State Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 mA minimum at 10V DC; 12.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 mA maximum at 31.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOff-State Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0V DC maximum.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Certification:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSIL2 capable for use in safety-instrumented systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFilter Time:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-configurable input filtering to eliminate electrical noise and contact bounce.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDraws 30 mA at 5V DC from the communication adapter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTerminal Base Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for use with 1794-TB2,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-TB3,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1794-TB3S,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand other FLEX I\/O bases.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOperating temperature from -20°C to +60°C (-4°F to +140°F).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eInstallation and Industrial Reliability\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1794-IB16 is optimized for space-constrained control cabinets,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering a small footprint without sacrificing ruggedness.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts digital circuitry is protected against industrial transients,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that high-speed signal processing remains accurate in environments with heavy motor noise or electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIntegration into the Rockwell Automation ecosystem is seamless through Studio 5000 or RSLogix software,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhere engineers can define input delay times to match specific application requirements.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhether deployed in automotive assembly,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ematerial handling,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor food and beverage processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1794-IB16 provides the deterministic data acquisition necessary for real-time logic execution.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts robust design and global certifications make it a reliable choice for both domestic USA projects and international industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519118893229,"sku":"1794-IB16","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1794-ib16-flex-16-point-digital-input-module-ylgxyfwja2i.jpg?v=1766987341"},{"product_id":"1734-485asc-allen-bradley-serial-interface-module-point-i-o","title":"1734-485ASC Allen-Bradley Serial Interface Module POINT I\/O","description":"\u003cp\u003eConfigured for serial communication data routing in industrial networks, the \u003cstrong\u003eAllen-Bradley 1734-485ASC\u003c\/strong\u003e (\u003cstrong\u003e1734-485ASC\u003c\/strong\u003e Point I\/O module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Architectural Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Base: 1734\u003c\/li\u003e\n\u003cli\u003eModule Variant: 485ASC Serial Interface\u003c\/li\u003e\n\u003cli\u003eSeries Platform: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eKey Switch Position: 2\u003c\/li\u003e\n\u003cli\u003eNominal Supply Voltage: 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-485ASC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 cm x 14 cm x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10 V DC to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eIntegrated across Profinet and EtherNet\/IP deterministic networks, this serial module supports backplane bus communication velocity and I\/O density scaling. The onboard processing logic manages protocol conversion latencies and ensures firmware flash compatibility, allowing seamless integration of legacy serial field instruments into modern distributed control architectures without compromising packet transmission timing.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-485ASC Serial Interface Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal base connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation bulletin reference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Clearance: Maintain adequate vertical and horizontal spacing around the module housing to allow for proper convective airflow and thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the unit firmly onto a standard 35 mm industrial DIN rail, verifying that the mechanical locking mechanism engages completely.\u003c\/li\u003e\n\u003cli\u003eWiring Termination: Connect incoming power and serial communication lines securely into the terminal blocks, ensuring proper conductor strip length to prevent exposed copper.\u003c\/li\u003e\n\u003cli\u003eGrounding Compliance: Fasten the base assembly directly to a grounded metal panel or mounting plate to mitigate electromagnetic interference and ensure noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the primary operational function of this hardware module?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit functions as a dedicated serial interface module designed to connect serial communication devices into distributed point I\/O systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the specified supply voltage range for proper operation?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt operates across an input voltage range spanning from 10 V DC to 28.8 V DC, with a nominal supply rating of 24 V DC.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the current consumption draw under normal operating conditions?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module draws a supply current of 15 mA when powered at 24 V DC.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat mechanical key switch position is assigned to this hardware variant?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe physical key switch is configured at position 2 to prevent incorrect module insertion on the backplane base.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the physical weight of the module unit?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe hardware weighs precisely 0.26 kg.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat are the estimated packaged shipping dimensions?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe shipping dimensions measure 3.5 cm x 14 cm x 14.5 cm.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhere is the manufacturing origin of this component?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe country of origin is designated as the USA.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhich industrial system platform accommodates this module?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is engineered exclusively for integration within the Allen-Bradley POINT I\/O distributed hardware platform.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066398822573,"sku":"1734-485ASC","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-485ASC3.jpg?v=1784728062"},{"product_id":"1734-4iol-allen-bradley-point-i-o-point-io-link-master-module","title":"1734-4IOL Allen-Bradley Point I\/O Point IO-Link Master Module","description":"\u003cp\u003eConfigured for distributed sensor communication and data multiplexing within industrial automation networks, the \u003cstrong\u003eAllen-Bradley 1734-4IOL\u003c\/strong\u003e (\u003cstrong\u003e1734-4IOL\u003c\/strong\u003e Point IO-Link Master Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Architectural Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Base: 1734\u003c\/li\u003e\n\u003cli\u003eModule Family: Point I\/O\u003c\/li\u003e\n\u003cli\u003eFunctional Variant: IO-Link Master\u003c\/li\u003e\n\u003cli\u003eChannel Density: 4-Channel Configuration\u003c\/li\u003e\n\u003cli\u003eOperational Voltage: 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-4IOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.5 cm x 7 cm x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eDistributed I\/O IO-Link Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eIntegrated across Profinet and EtherNet\/IP deterministic networks, this communication module sustains backplane bus communication velocity and I\/O density scaling. The internal processing architecture manages protocol conversion latencies and supports firmware flash compatibility, ensuring synchronized data exchange between smart field devices and the central controller without introducing communication jitter or packet loss across distributed network nodes.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-4IOL Point IO-Link Master Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal block base connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Clearance: Maintain adequate vertical and horizontal spacing around the module housing to allow for proper thermal dissipation and ambient airflow.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Securely mount the unit onto a standard 35 mm industrial DIN rail, verifying that the locking mechanism engages completely.\u003c\/li\u003e\n\u003cli\u003eWiring Termination: Connect incoming 24 V DC power supplies and IO-Link field device cables to the designated terminal points, ensuring secure mechanical clamping.\u003c\/li\u003e\n\u003cli\u003eGrounding Compliance: Fasten the base assembly directly to a grounded metal panel to mitigate electromagnetic interference and ensure noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat are the recommended practices for physical mounting and enclosure clearance?\u003c\/li\u003e\n\u003cli\u003eThe module must be installed within a protective industrial enclosure mounted securely onto a standard DIN rail, ensuring sufficient top and bottom clearance to maintain adequate convective airflow.\u003c\/li\u003e\n\u003cli\u003eHow should cable shielding and grounding be executed for IO-Link communication ports?\u003c\/li\u003e\n\u003cli\u003eCable shields must be terminated directly to a low-impedance ground bus bar using proper metal clamping brackets to prevent high-frequency electromagnetic interference from corrupting data packets.\u003c\/li\u003e\n\u003cli\u003eWhat are the strict wiring segregation and routing limitations in the control cabinet?\u003c\/li\u003e\n\u003cli\u003eLow-voltage digital and communication cables must be segregated physically from high-voltage power lines and motor drive cables within separate metal conduits or cable trays to minimize electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eWhat standard industrial practices apply to wire stripping and terminal insertion?\u003c\/li\u003e\n\u003cli\u003eConductors must be stripped to the exact length specified by the manufacturer without exposing bare copper outside the terminal, and stranded wires must be fully inserted to avoid stray strands causing short circuits.\u003c\/li\u003e\n\u003cli\u003eAre there specific torque limits when securing terminal block connections?\u003c\/li\u003e\n\u003cli\u003eScrews on terminal blocks must be tightened using calibrated tools to avoid under-tightening that causes high contact resistance or over-tightening that shears screw threads.\u003c\/li\u003e\n\u003cli\u003eHow should power distribution lines be protected against transient voltage surges?\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels must incorporate appropriate surge suppression devices and fuses on incoming power branches to protect sensitive electronics from grid transients and lightning-induced spikes.\u003c\/li\u003e\n\u003cli\u003eWhat environmental conditions must be avoided during field installation?\u003c\/li\u003e\n\u003cli\u003eInstallation locations must be free from excessive moisture, corrosive gases, severe continuous vibration, and ambient temperatures exceeding the designated hardware specifications.\u003c\/li\u003e\n\u003cli\u003eHow is proper continuity verified across the common grounding system?\u003c\/li\u003e\n\u003cli\u003eSystem integrators must verify that all panel backplanes, DIN rails, and shielding bars exhibit low-resistance metallic bonding back to the main earth ground stud of the facility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066398855341,"sku":"1734-4IOL","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-4IOL_13.jpg?v=1784727912"},{"product_id":"1734-8cfgdlx-allen-bradley-dc-configurable-i-o-module-point-i-o-series","title":"1734-8CFGDLX Allen-Bradley DC Configurable I\/O Module POINT I\/O Series","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-8CFGDLX\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-8CFGDLX\u003c\/strong\u003e DC Configurable I\/O Module, operates as a dedicated hardware component for configurable digital signal acquisition and output execution within POINT I\/O system networks.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1734-8CFGDLX is an 8-channel DC configurable I\/O module designed for installation within the Allen-Bradley POINT I\/O platform. The module supports configurable field-side channels for industrial digital signal processing through a DIN rail mounted distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-8CFGDLX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Configurable I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Channels\u003c\/td\u003e\n\u003ctd\u003e8 configurable channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e11 Volts DC minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2-5 milliamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Platform\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O backplane communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Platform Integration\u003c\/h3\u003e\n\u003cp\u003eAllen-Bradley POINT I\/O modules are designed for distributed PLC architectures where remote I\/O density scaling and deterministic EtherNet\/IP network communication are required. The 1734-8CFGDLX connects through the POINT I\/O backplane assembly and exchanges process data with the controller through the configured network adapter.\u003c\/p\u003e\n\u003cp\u003eThe module configuration supports flexible channel assignment, allowing the I\/O density of a POINT I\/O station to be adjusted according to field device requirements. Firmware flash compatibility should be verified before installation to ensure alignment between the module revision and the controller environment.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-8CFGDLX DC Configurable I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x Factory-installed electronic assembly\u003c\/li\u003e\n\u003cli\u003ePOINT I\/O terminal base assembly is required separately if not already available\u003c\/li\u003e\n\u003cli\u003eNetwork adapter and power distribution accessories are ordered separately according to system architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible DIN rail with the correct POINT I\/O terminal base.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module for wiring access and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal base connection is fully seated before applying system power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm field voltage levels before connecting DC input circuits.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring separately from high-current power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the control cabinet grounding design.\u003c\/li\u003e\n\u003cli\u003eVerify module addressing and controller configuration before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat type of signals does the 1734-8CFGDLX process?\u003c\/strong\u003e\u003cbr\u003eThe module processes configurable DC digital field signals through its 8-channel I\/O interface within a POINT I\/O distributed control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the 1734-8CFGDLX compatible with POINT I\/O systems?\u003c\/strong\u003e\u003cbr\u003eYes. The module is designed specifically for installation within the Allen-Bradley POINT I\/O platform using compatible terminal bases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the module require a separate terminal base?\u003c\/strong\u003e\u003cbr\u003eYes. POINT I\/O modules typically require a compatible terminal base assembly for field wiring connection and mechanical mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the module be installed on a standard DIN rail?\u003c\/strong\u003e\u003cbr\u003eYes. The module uses DIN rail mounting as part of the POINT I\/O distributed I\/O installation method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range of this module?\u003c\/strong\u003e\u003cbr\u003eThe specified operating temperature range is -20 to 55 deg C for standard industrial installation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the minimum input voltage requirement?\u003c\/strong\u003e\u003cbr\u003eThe module requires a minimum input voltage of 11 Volts DC according to the provided technical specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the module support firmware updates?\u003c\/strong\u003e\u003cbr\u003eFirmware compatibility depends on the installed controller environment and POINT I\/O system revision. Verify revision requirements before updating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow should field wiring be installed?\u003c\/strong\u003e\u003cbr\u003eField wiring should follow industrial control practices, including proper grounding, signal separation, and protection against electrical noise sources.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066398920877,"sku":"1734-8CFGDLX","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-8CFGDLX_13.jpg?v=1784730778"},{"product_id":"1734-acnr-allen-bradley-point-i-o-series-24v-dc-controlnet-adapter","title":"1734-ACNR Allen-Bradley POINT I\/O Series 24V DC ControlNet Adapter","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-ACNR\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-ACNR\u003c\/strong\u003e Point I\/O 24V DC ControlNet Adapter, operates as a dedicated hardware component for ControlNet network communication and POINTBus I\/O data exchange within Allen-Bradley POINT I\/O system platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1734-ACNR is a dual-media ControlNet adapter designed to connect POINT I\/O modules to a ControlNet network infrastructure. The adapter provides communication between the ControlNet network and local POINTBus modules, supporting up to 63 POINT I\/O modules within a single station.\u003c\/p\u003e\n\u003cp\u003eThe spare model reference includes 1734ACNR and 1734-ACNR\/A versions. The unit requires 24 VDC field power and provides POINTBus current capacity for connected I\/O assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-ACNR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePoint I\/O ControlNet Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eControlNet Dual Media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 63 POINT I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e6 A for 10 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e425 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current Capacity\u003c\/td\u003e\n\u003ctd\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 x 7.6 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and Industrial Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley POINT I\/O architecture uses distributed I\/O communication technology to connect remote field devices with PLC control systems. The 1734-ACNR adapter provides ControlNet network access while maintaining local POINTBus communication with installed I\/O modules.\u003c\/p\u003e\n\u003cp\u003eThe adapter supports I\/O density scaling by allowing multiple POINT I\/O modules to operate within a single remote station. System configuration requires matching the adapter revision, controller configuration, and network parameters to maintain deterministic ControlNet communication.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility should be verified before replacement or system upgrades to ensure correct operation with the existing ControlNet infrastructure.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-ACNR ControlNet Adapter\u003c\/li\u003e\n\u003cli\u003e1 x POINT I\/O communication adapter assembly\u003c\/li\u003e\n\u003cli\u003eCompatible POINT I\/O terminal bases are ordered separately when required\u003c\/li\u003e\n\u003cli\u003eControlNet network cables and connectors are supplied separately according to installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMount the adapter on a compatible DIN rail within the POINT I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eEnsure the adapter is correctly seated with adjacent terminal bases before applying power.\u003c\/li\u003e\n\u003cli\u003eInstall the module in an enclosure suitable for the surrounding industrial environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical and Network Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the 24 VDC power supply according to the system wiring design.\u003c\/li\u003e\n\u003cli\u003eVerify power supply capacity based on connected POINT I\/O module load requirements.\u003c\/li\u003e\n\u003cli\u003eRoute ControlNet communication cables separately from high-current power conductors.\u003c\/li\u003e\n\u003cli\u003eApply proper cable shielding and grounding practices to reduce communication interference.\u003c\/li\u003e\n\u003cli\u003eConfirm network addressing and controller configuration before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat network protocol does the 1734-ACNR use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-ACNR operates as a ControlNet adapter for communication between ControlNet networks and POINT I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many POINT I\/O modules can connect to this adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe adapter supports up to 63 POINT I\/O modules within a single POINTBus I\/O station configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply does the 1734-ACNR require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe adapter requires a 24 VDC power source and has a specified power requirement of 425 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the POINTBus current capacity of this adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe adapter provides a POINTBus current capacity of 1000 mA for connected POINT I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-ACNR support DIN rail mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The adapter is designed for DIN rail mounting as part of the POINT I\/O distributed I\/O system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1734-ACNR a standalone controller module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The unit functions as a network communication adapter and requires POINT I\/O modules for field signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the adapter be replaced without configuration changes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplacement requires verification of ControlNet addressing, module revision compatibility, and controller configuration parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation practice is recommended for ControlNet wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eControlNet cables should be routed separately from power wiring with correct shielding and grounding methods applied.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066398986413,"sku":"1734-ACNR","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-ACNR3.jpg?v=1784730675"},{"product_id":"allen-bradley-1734-adn-point-i-o-devicenet-network-adaptor","title":"Allen-Bradley 1734-ADN POINT I\/O DeviceNet Network Adaptor","description":"\u003cp\u003eConfigured for DeviceNet communication between POINT I\/O modules and controller networks, the \u003cstrong\u003eAllen-Bradley 1734-ADN\u003c\/strong\u003e (\u003cstrong\u003e1734-ADN\u003c\/strong\u003e DeviceNet Network Adaptor) provides direct physical network interface execution.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1734-ADN is a POINT I\/O communication adaptor designed for DeviceNet networks. The module provides the interface between distributed POINT I\/O terminal modules and the DeviceNet fieldbus infrastructure. The device supports modular I\/O expansion with a DeviceNet communication rate range from 125 Kbit\/s to 500 Kbit\/s.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-ADN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O DeviceNet Network Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O 1734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Speed\u003c\/td\u003e\n\u003ctd\u003e125 Kbit\/s to 500 Kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e504 I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSingapore \/ United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e13.2 x 5.6 x 8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC supply, 50 mA current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail modular mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and Industrial Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe POINT I\/O platform uses modular communication adaptors to connect remote I\/O assemblies with industrial controller networks. The 1734-ADN performs DeviceNet protocol communication, managing data exchange between field-connected I\/O modules and the network master.\u003c\/p\u003e\n\u003cp\u003eThe module supports I\/O density scaling by allowing multiple POINT I\/O modules to be installed on a common backplane assembly. DeviceNet communication parameters are determined by the selected network baud rate and controller configuration.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe shipment configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-ADN POINT I\/O DeviceNet Network Adaptor\u003c\/li\u003e\n\u003cli\u003e1 x Standard product housing assembly\u003c\/li\u003e\n\u003cli\u003e1 x Terminal connection interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional POINT I\/O terminal modules and DeviceNet accessories are installed separately according to system configuration requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the adaptor on a compatible DIN rail section with proper mechanical locking.\u003c\/li\u003e\n\u003cli\u003eConfirm module alignment before connecting adjacent POINT I\/O modules.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient clearance for wiring access and maintenance operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDeviceNet Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse DeviceNet-compatible cable and follow network topology requirements.\u003c\/li\u003e\n\u003cli\u003eSeparate communication wiring from high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eConnect shield grounding according to the installation design of the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the 24 VDC supply polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eCheck current loading when additional POINT I\/O modules are connected.\u003c\/li\u003e\n\u003cli\u003eConfirm network addressing before controller communication testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication protocol does the 1734-ADN use?\u003c\/p\u003e\n\u003cp\u003eThe 1734-ADN uses DeviceNet communication protocol for connection between POINT I\/O modules and the network controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage is required for this adaptor?\u003c\/p\u003e\n\u003cp\u003eThe module operates with a 24 VDC supply input according to the provided technical specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many I\/O points can the adaptor support?\u003c\/p\u003e\n\u003cp\u003eThe 1734-ADN supports a maximum configuration of 504 I\/O points within the POINT I\/O system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat DeviceNet baud rates are supported?\u003c\/p\u003e\n\u003cp\u003eThe adaptor supports DeviceNet communication speeds from 125 Kbit\/s to 500 Kbit\/s.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the module be installed on DIN rail?\u003c\/p\u003e\n\u003cp\u003eYes. The 1734-ADN is designed for modular DIN rail installation within POINT I\/O assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the adaptor provide field signal conversion?\u003c\/p\u003e\n\u003cp\u003eNo. The module provides network communication functions and requires separate POINT I\/O modules for signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the module part of the POINT I\/O 1734 family?\u003c\/p\u003e\n\u003cp\u003eYes. The 1734-ADN belongs to the Allen-Bradley POINT I\/O 1734 product family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre additional I\/O modules required for operation?\u003c\/p\u003e\n\u003cp\u003eYes. The adaptor functions as a communication interface and normally operates with connected POINT I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399019181,"sku":"1734-ADN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-ADN_13.jpg?v=1784729947"},{"product_id":"1734-aent-allen-bradley-point-i-o-ethernet-network-adaptor-point-i-o","title":"1734-AENT Allen-Bradley POINT I\/O Ethernet Network Adaptor Point I\/O","description":"\u003cp\u003eConfigured for Ethernet network communications and distributed I\/O bridging within industrial automation systems, the \u003cstrong\u003eAllen-Bradley 1734-AENT\u003c\/strong\u003e (\u003cstrong\u003e1734-AENT\u003c\/strong\u003e POINT I\/O Ethernet Network Adaptor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Architectural Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Base: 1734\u003c\/li\u003e\n\u003cli\u003eModule Type: Ethernet Network Adaptor\u003c\/li\u003e\n\u003cli\u003eSeries Platform: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eSpare Model Identifier: 1734AENT\u003c\/li\u003e\n\u003cli\u003eSupported Chassis Size: 4 Modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-AENT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e13.2 cm x 5.7 cm x 7.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eIntegrated across Profinet and EtherNet\/IP deterministic networks, this communication module manages backplane bus communication velocity and I\/O density scaling. The onboard processing architecture handles protocol conversion latencies and supports firmware flash compatibility, maintaining synchronized data transmission across distributed network nodes without introducing packet jitter or communication drops.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-AENT POINT I\/O Ethernet Network Adaptor unit\u003c\/li\u003e\n\u003cli\u003e1 x RJ-45 communication port interface connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Clearance: Maintain adequate vertical and horizontal spacing around the open-style housing to allow for proper convective airflow and thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the adaptor firmly onto a standard 35 mm industrial DIN rail, verifying that the mechanical locking mechanism engages completely.\u003c\/li\u003e\n\u003cli\u003eWiring Termination: Connect incoming 24 V DC power lines and Category 5 Ethernet cables securely, ensuring proper wire gauge insulation limits.\u003c\/li\u003e\n\u003cli\u003eGrounding Compliance: Fasten the base assembly directly to a grounded metal mounting panel to suppress electromagnetic interference and ensure noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary operational function of this network adaptor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit functions as an Ethernet network adaptor designed to bridge distributed Point I\/O modules with higher-level automation controllers over industrial networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum module capacity supported by the adaptor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The adaptor supports a maximum expansion I\/O capacity of up to 63 modules and 31 direct connections depending on configuration rules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the supported network communication rates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It operates at communication rates of 10 or 100 Mbits\/s, supporting both half and full-duplex transmission modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of physical connector is utilized for network cabling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Network connections are established using standard RJ-45 ports compatible with Category 5 Ethernet media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the nominal input voltage requirement for power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit operates on a rated supply voltage of 24 V DC with built-in reverse polarity protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the specified electrical isolation rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The hardware provides a continuous isolation voltage rating of 50 V.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the physical weight of the communication adaptor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit weighs precisely 0.24 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the estimated packaged shipping dimensions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The shipping dimensions measure 13.2 cm x 5.7 cm x 7.5 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399084717,"sku":"1734-AENT","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-AENT_13.jpg?v=1784728493"},{"product_id":"allen-bradley-1734-aentr-network-adapter-module-point-i-o","title":"Allen-Bradley 1734-AENTR Network Adapter Module Point I\/O","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-AENTR\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734AENTR\u003c\/strong\u003e Network Adapter Module, operates as a dedicated hardware component for bridging Ethernet\/IP communications to Point I\/O rack modules within industrial automation architectures.\u003c\/p\u003e\n\u003ch3\u003eCatalog Nomenclature and Mapping Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1734-AENTR: Base catalog number for the 2-port EtherNet\/IP communication adapter\u003c\/li\u003e\n\u003cli\u003e1734AENTR: Alternative manufacturer identification string without separator hyphens\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-AENTR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e13.3 cm x 7.3 cm x 8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e55 deg C max surrounding air temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.4 W max at 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 VDC to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Communication Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbits\/s, half or full-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Networks and Bus Architecture\u003c\/h3\u003e\n\u003cp\u003eThe unit relies on deterministic EtherNet\/IP networks to manage data exchanges between connected I\/O nodes and central controllers across star, tree, linear, or device-level ring topologies. Backplane bus communication velocity coordinates module execution limits up to a 63-module capacity on the internal PointBus. I\/O density scaling allows seamless expansion without violating backplane current loading limits or inducing protocol conversion latencies. Firmware flash compatibility is managed through system software tools to preserve operational baseline stability across controller updates.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-AENTR Network Adapter Module\u003c\/li\u003e\n\u003cli\u003e1 x Removable Marker Carrier\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Data Sheet Reference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Instructions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting Mechanics\n\u003cul\u003e\n\u003cli\u003eSecure the adapter module firmly onto a standard 35 mm industrial DIN rail inside an appropriate protective enclosure.\u003c\/li\u003e\n\u003cli\u003eAlign the module slide latch and push down until it locks securely into place on the rail structure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eNetwork and Power Cabling\n\u003cul\u003e\n\u003cli\u003eConnect shielded twisted-pair Ethernet cables into the RJ-45 communication ports supporting ring or linear topologies.\u003c\/li\u003e\n\u003cli\u003eTerminate the external 24 VDC power supply lines to the removable terminal block while respecting polarity limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Technical Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the maximum number of I\/O modules supported by this adapter?\u003c\/li\u003e\n\u003cli\u003eA: The adapter supports a maximum capacity of 63 expansion modules connected along the PointBus.\u003c\/li\u003e\n\u003cli\u003eQ: What communication rates do the Ethernet ports support?\u003c\/li\u003e\n\u003cli\u003eA: The ports support 10\/100 Mbits\/s communication speeds in both half and full-duplex modes.\u003c\/li\u003e\n\u003cli\u003eQ: How is the IP address assigned to the communication adapter?\u003c\/li\u003e\n\u003cli\u003eA: IP configuration is managed using BOOTP\/DHCP utilities or physical thumbwheel switches located on the device.\u003c\/li\u003e\n\u003cli\u003eQ: Does the hardware support ring network topologies?\u003c\/li\u003e\n\u003cli\u003eA: Yes, the dual Ethernet ports support Device Level Ring (DLR) topologies for network media redundancy.\u003c\/li\u003e\n\u003cli\u003eQ: What happens if an attached I\/O module fails to respond to a request?\u003c\/li\u003e\n\u003cli\u003eA: The adapter generates an error code indicating a communication time-out back to the controller.\u003c\/li\u003e\n\u003cli\u003eQ: What is the maximum inrush current rating during startup?\u003c\/li\u003e\n\u003cli\u003eA: The maximum inrush current reaches 6 A for a duration of 10 milliseconds.\u003c\/li\u003e\n\u003cli\u003eQ: Is hot-swapping permitted for expansion modules on the active PointBus?\u003c\/li\u003e\n\u003cli\u003eA: Expansion modules can be replaced under power if supported by system architecture, but rack power rules apply.\u003c\/li\u003e\n\u003cli\u003eQ: What is the maximum field side power rating supplied through the adapter?\u003c\/li\u003e\n\u003cli\u003eA: The field side power is rated for a maximum of 24 VDC at 400 mA.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399117485,"sku":"1734-AENTR","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-AENTR3.jpg?v=1784730316"},{"product_id":"1734-ctm-allen-bradley-point-i-o-terminal-module","title":"1734-CTM Allen-Bradley POINT I\/O Terminal Module","description":"\u003cp\u003eConfigured for field power distribution and signal termination in distributed automation nodes, the \u003cstrong\u003eAllen-Bradley 1734-CTM\u003c\/strong\u003e (\u003cstrong\u003e1734-CTM\u003c\/strong\u003e POINT I\/O Terminal Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Identification and Suffix Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Identifier: 1734-CTM\u003c\/li\u003e\n\u003cli\u003eSpare Model Reference: 1734CTM\u003c\/li\u003e\n\u003cli\u003eSeries Platform: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eHardware Module Class: Terminal Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-CTM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.2 x 5.6 x 7.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Field Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 Volts Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply\u003c\/td\u003e\n\u003ctd\u003e1 to 28.8 V DC or 12\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply Current\u003c\/td\u003e\n\u003ctd\u003e4 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane and Deterministic Network Parameters\u003c\/h3\u003e\n\u003cp\u003eThe module integrates within Allen-Bradley node racks, managing backplane bus communication velocity limits. Firmware flash compatibility ensures alignment with host controller architectures, supporting deterministic EtherNet\/IP networks and optimized I\/O density scaling across distributed physical loops.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-CTM Terminal Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Field power distribution jumper reference sheet\u003c\/li\u003e\n\u003cli\u003e1 x Terminal block housing component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Deployment Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the module firmly onto standard 35 mm DIN rails inside the designated control cabinet.\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: Verify that connected field power circuits do not exceed the 250 Volts continuous isolation threshold.\u003c\/li\u003e\n\u003cli\u003eCurrent Load Management: Ensure total current draw across the terminal block assembly remains within the 4 A per module limit.\u003c\/li\u003e\n\u003cli\u003eCircuit Protection: Install external fusing on incoming field power supply lines to protect against overcurrent faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry and Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous isolation voltage rating of the module?\u003c\/p\u003e\n\u003cp\u003eThe isolation voltage rating is 250 Volts continuous.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the supported field power supply voltage ranges?\u003c\/p\u003e\n\u003cp\u003eThe field power supply supports 1 to 28.8 V DC or 12\/240 V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum field power supply current capacity per module?\u003c\/p\u003e\n\u003cp\u003eThe maximum current capacity is 4 A per module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical series platform does the unit belong to?\u003c\/p\u003e\n\u003cp\u003eThe unit belongs to the POINT I\/O series platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the designated country of origin for manufacturing?\u003c\/p\u003e\n\u003cp\u003eThe country of origin is the USA, with shipment originating from Xiamen, China.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recorded weight of the hardware component?\u003c\/p\u003e\n\u003cp\u003eThe weight of the module is 0.04 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the estimated shipping dimensions of the package?\u003c\/p\u003e\n\u003cp\u003eThe shipping dimensions are 1.2 x 5.6 x 7.2 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat function does the terminal module execute in a control assembly?\u003c\/p\u003e\n\u003cp\u003eIt provides physical field power distribution and wiring termination support across I\/O nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399215789,"sku":"1734-CTM","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-CTM_24.jpg?v=1784732344"},{"product_id":"1734-fpd-allen-bradley-point-i-o-field-distributor-module","title":"1734-FPD Allen-Bradley POINT I\/O Field Distributor Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-FPD\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-FPD\u003c\/strong\u003e POINT I\/O Field Distributor Module, operates as a dedicated hardware component for field power segmentation and distribution within Allen-Bradley POINT I\/O control architectures.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-FPD is a POINT I\/O Field Power Distributor module designed to separate and distribute field power groups within a distributed I\/O assembly. The module allows separate field power sections to be created without interrupting the controller communication structure.\u003c\/p\u003e\n\u003cp\u003eThe module supports 10 to 28.8 VDC field power distribution, up to 120\/240 VAC compatibility, and a maximum current rating of 10 A for connected field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-FPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSingapore, United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 7.8 x 13.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eField Distributor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Range\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Compatibility\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePOINT I\/O Power Distribution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1734-FPD supports I\/O density scaling by dividing field power distribution into separate segments within a POINT I\/O system. This allows different groups of field devices to receive power from independent field supply sections.\u003c\/p\u003e\n\u003cp\u003eThe module operates as a passive field power distribution component and does not process controller data. POINT I\/O backplane communication continues through the assembled system while field power zones are separated.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control architectures using compatible POINT I\/O adapters and EtherNet\/IP based deterministic networks. Proper firmware compatibility between communication adapters, controllers, and configuration software is required during system installation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-FPD POINT I\/O Field Distributor Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional POINT I\/O components required for installation may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOINT I\/O terminal base assembly\u003c\/li\u003e\n\u003cli\u003eCompatible communication adapter\u003c\/li\u003e\n\u003cli\u003eExternal field power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on a compatible DIN rail installation.\u003c\/li\u003e\n\u003cli\u003eInstall the module within the correct position of the POINT I\/O assembly.\u003c\/li\u003e\n\u003cli\u003eVerify terminal base connection before applying field power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm field power voltage range before connection.\u003c\/li\u003e\n\u003cli\u003eSeparate field power groups according to system design requirements.\u003c\/li\u003e\n\u003cli\u003eUse suitable wiring methods for the connected load current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSystem Verification\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCheck power distribution status after installation.\u003c\/li\u003e\n\u003cli\u003eConfirm correct field power separation between I\/O groups.\u003c\/li\u003e\n\u003cli\u003eVerify communication operation after modifying the POINT I\/O assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFirmware and Network Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1734-FPD functions within the Allen-Bradley POINT I\/O modular platform and supports distributed control installations requiring segmented field power management.\u003c\/p\u003e\n\u003cp\u003eThe module does not provide communication processing or signal conversion functions. Its operation depends on the installed POINT I\/O assembly, terminal base configuration, and connected field power supply arrangement.\u003c\/p\u003e\n\u003cp\u003eSystem expansion should consider available field power capacity, adapter limitations, and overall I\/O density requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the 1734-FPD?\u003c\/p\u003e\n\u003cp\u003eThe module distributes and separates field power sections within a POINT I\/O assembly without processing I\/O signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 1734-FPD communicate with the controller?\u003c\/p\u003e\n\u003cp\u003eNo. The module is a field power distribution component and does not exchange controller data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage range can the module distribute?\u003c\/p\u003e\n\u003cp\u003eThe module supports field power from 10 to 28.8 VDC according to the provided specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the module be installed on DIN rail?\u003c\/p\u003e\n\u003cp\u003eYes. The POINT I\/O Field Distributor module is designed for DIN rail mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum current rating?\u003c\/p\u003e\n\u003cp\u003eThe module supports a maximum field current rating of 10 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module replace a POINT I\/O adapter?\u003c\/p\u003e\n\u003cp\u003eNo. The module requires a compatible POINT I\/O communication adapter within the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan field power groups be separated using this module?\u003c\/p\u003e\n\u003cp\u003eYes. The module allows field power segmentation between different POINT I\/O sections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat should be checked before installation?\u003c\/p\u003e\n\u003cp\u003eVerify terminal base compatibility, field voltage requirements, and wiring arrangement before applying power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399248557,"sku":"1734-FPD","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-FPD3.jpg?v=1784729655"},{"product_id":"1734-ib4-allen-bradley-point-i-o-4-channel-input-module","title":"1734-IB4 Allen-Bradley Point I\/O 4 Channel Input Module","description":"\u003cp\u003eConfigured for discrete signal acquisition within distributed industrial automation frameworks, the \u003cstrong\u003eAllen-Bradley 1734-IB4\u003c\/strong\u003e (\u003cstrong\u003e1734-IB4\u003c\/strong\u003e 4 Channel Input Module) executes real-time digital state monitoring at the local node level.\u003c\/p\u003e\n\u003ch3\u003eModel Cataloging and Variant Identifiers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary Catalog Number: 1734-IB4\u003c\/li\u003e\n\u003cli\u003eAlternative Part Reference: 1734IB4\u003c\/li\u003e\n\u003cli\u003eHardware Architecture: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eFunctional Module Class: 4-Channel Digital DC Input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IB4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.0 x 6.0 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 Point Discrete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8538907080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and Deterministic Processing\u003c\/h3\u003e\n\u003cp\u003eThe unit interfaces directly with the local POINTBus backplane, maintaining high-speed data exchange rates with the parent adapter. Firmware flash compatibility allows seamless integration across various Logix controller revisions, supporting deterministic network updates and scalable I\/O node layouts without performance degradation.\u003c\/p\u003e\n\u003ch3\u003eBill of Materials and Order Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-IB4 Digital Input Module hardware assembly\u003c\/li\u003e\n\u003cli\u003e1 x Integrated DIN-rail mounting base latch\u003c\/li\u003e\n\u003cli\u003e1 x Technical documentation reference leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Deployment and Field Wiring Instructions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Securing: Snap the open-style module directly onto a standard 35 mm industrial mounting rail inside the control cabinet.\u003c\/li\u003e\n\u003cli\u003eTerminal Interlock: Align the module housing precisely with the corresponding wiring base assembly to ensure robust pin engagement.\u003c\/li\u003e\n\u003cli\u003eCircuit Protection: Ensure external DC power sources feeding the sensor loops are regulated and fused appropriately.\u003c\/li\u003e\n\u003cli\u003eSignal Shielding: Route field input cables away from high-voltage AC lines to prevent induced electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry and System Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow many independent input channels does this module provide?\u003c\/p\u003e\n\u003cp\u003eThe module provides 4 discrete digital input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard operational voltage for the input circuits?\u003c\/p\u003e\n\u003cp\u003eThe input circuits operate on a nominal 24 V DC supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical mounting style is required for installation?\u003c\/p\u003e\n\u003cp\u003eThe unit is designed for standard 35 mm DIN-rail mounting configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the exact physical weight of the hardware module?\u003c\/p\u003e\n\u003cp\u003eThe unit weighs 0.04 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhere is the manufacturing origin of this hardware component?\u003c\/p\u003e\n\u003cp\u003eThe product is manufactured in the United States.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat customs tariff code applies to this specific part number?\u003c\/p\u003e\n\u003cp\u003eThe designated tariff code is 8538907080.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical packaging dimensions for shipping?\u003c\/p\u003e\n\u003cp\u003eThe estimated shipping size is 8.0 x 6.0 x 1.7 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support backplane communication diagnostics?\u003c\/p\u003e\n\u003cp\u003eYes, logic-side status indicators communicate operational health and communication states directly via the backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399346861,"sku":"1734-IB4","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IB4_14.jpg?v=1784731913"},{"product_id":"1734-ib8-allen-bradley-point-i-o-8-point-digital-input-module","title":"1734-IB8 Allen-Bradley POINT I\/O 8 Point Digital Input Module","description":"\u003cp\u003eConfigured for discrete signal acquisition in industrial control networks, the \u003cstrong\u003eAllen-Bradley 1734-IB8\u003c\/strong\u003e (\u003cstrong\u003e1734-IB8\u003c\/strong\u003e POINT I\/O 8 Point Digital Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Identification and Suffix Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Identifier: 1734-IB8\u003c\/li\u003e\n\u003cli\u003eSpare Model Reference: 1734IB8\u003c\/li\u003e\n\u003cli\u003ePlatform Series: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eHardware Module Class: 8-Point Digital DC Sinking Input Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IB8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e2 to 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Current\u003c\/td\u003e\n\u003ctd\u003e4 mA @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 Sinking Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eOpen-Style (None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyswitch Position\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane and Deterministic Network Parameters\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with backplane bus communication velocity frameworks within Allen-Bradley rack architectures. Firmware flash compatibility ensures alignment with contemporary controller revisions, allowing deterministic EtherNet\/IP networks and optimized I\/O density scaling across distributed nodes.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-IB8 Digital Input Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Mechanical keyswitch configuration guide\u003c\/li\u003e\n\u003cli\u003e1 x Hardware status indicator reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Deployment Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the open-style module firmly onto a standard 35 mm DIN rail within the designated control enclosure.\u003c\/li\u003e\n\u003cli\u003eBase Assembly: Mount the module exclusively onto a compatible 1734-TB or 1734-TBS wiring base assembly.\u003c\/li\u003e\n\u003cli\u003eKeyswitch Verification: Ensure the mechanical keyswitch is set to position 1 prior to physical module insertion.\u003c\/li\u003e\n\u003cli\u003eStatus Monitoring: Observe the logic-side green\/red module status indicator and eight yellow input status indicators during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry and Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal input voltage rating for the digital channels?\u003c\/p\u003e\n\u003cp\u003eThe nominal input voltage is 24 V DC with an operating range of 10 to 28.8 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many discrete input channels does the module support?\u003c\/p\u003e\n\u003cp\u003eThe module supports 8 sinking input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal input current drawn at 24 V DC?\u003c\/p\u003e\n\u003cp\u003eThe nominal input current is 4 mA at 24 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total power dissipation of the unit?\u003c\/p\u003e\n\u003cp\u003eThe power dissipation is 1.6 W or 5.5 BTU\/hour.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current is drawn from the internal POINTBus?\u003c\/p\u003e\n\u003cp\u003eThe POINTBus current draw is 75 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich wiring base assemblies are compatible with this module?\u003c\/p\u003e\n\u003cp\u003eThe module mounts onto 1734-TB or 1734-TBS wiring base assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the pre-configured physical keyswitch position?\u003c\/p\u003e\n\u003cp\u003eThe keyswitch position is set to 1.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of enclosure rating does the hardware feature?\u003c\/p\u003e\n\u003cp\u003eThe module features an open-style enclosure with no rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399379629,"sku":"1734-IB8","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-ib8_15.jpg?v=1784732886"},{"product_id":"1734-ie2c-allen-bradley-point-i-o-2-point-analog-input-module-point-i-o","title":"1734-IE2C Allen-Bradley POINT I\/O 2 Point Analog Input Module POINT I\/O","description":"\u003cp\u003eConfigured for analog signal acquisition in industrial control networks, the \u003cstrong\u003eAllen-Bradley 1734-IE2C\u003c\/strong\u003e (\u003cstrong\u003e1734-IE2C\u003c\/strong\u003e POINT I\/O 2 Point Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Cataloging and Suffix Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Identifier: 1734-IE2C\u003c\/li\u003e\n\u003cli\u003eSpare Model Reference: 1734IE2C\u003c\/li\u003e\n\u003cli\u003eSeries Platform: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eHardware Module Class: 2-Point Analog Input Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IE2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.6 W @ 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2-Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eDelta Sigma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory Calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overload Fault Protected\u003c\/td\u003e\n\u003ctd\u003e28.8 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eSigned Integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% Full Scale @ 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane and Deterministic Network Parameters\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with backplane bus communication protocols within Allen-Bradley rack architectures. Firmware flash compatibility ensures alignment with contemporary controller revisions, allowing deterministic I\/O density scaling across distributed nodes. Backplane power draw is maintained at 75 mA from the 5 V DC bus, ensuring minimal thermal dissipation loads across high-density node assemblies.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-IE2C Analog Input Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Factory calibration documentation sheet\u003c\/li\u003e\n\u003cli\u003e1 x Mechanical keyswitch configuration guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Deployment Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Ensure secure physical attachment to standard 35 mm DIN rails within the designated enclosure.\u003c\/li\u003e\n\u003cli\u003eShielded Cabling: Terminate signal cable shields to designated chassis ground points to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eKeyswitch Setting: Verify the physical keyswitch position is set to 3 prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eTerminal Powering: Ensure external loop power supplies remain within the 10 to 28.8 V DC range to prevent input circuit faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry and Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal current draw from the 5 V DC backplane?\u003c\/p\u003e\n\u003cp\u003eThe module draws 75 mA from the 5 V DC backplane bus during normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat data format is utilized for the acquired analog values?\u003c\/p\u003e\n\u003cp\u003eAnalog input values are processed and transmitted in a Signed Integer data format.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the factory-set absolute accuracy of the module?\u003c\/p\u003e\n\u003cp\u003eThe absolute accuracy is specified at 0.1% Full Scale at an ambient temperature of 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the configured keyswitch position for this hardware revision?\u003c\/p\u003e\n\u003cp\u003eThe physical keyswitch position for this module variant is set to 3.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many input channels are supported per physical module?\u003c\/p\u003e\n\u003cp\u003eThe module supports exactly 2-Point single-ended current input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total power dissipation rating at maximum voltage?\u003c\/p\u003e\n\u003cp\u003eThe power dissipation is rated at 0.6 W at 28.8 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of analog-to-digital conversion technique is employed?\u003c\/p\u003e\n\u003cp\u003eThe hardware utilizes a Delta Sigma conversion architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the default input step response time per channel?\u003c\/p\u003e\n\u003cp\u003eThe default input step response is 70 ms when the notch filter is set to 60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399445165,"sku":"1734-IE2C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IE2C_13.jpg?v=1784733379"},{"product_id":"1734-ie2v-allen-bradley-point-i-o-point-i-o-analog-input-module","title":"1734-IE2V Allen-Bradley POINT I\/O POINT I\/O Analog Input Module","description":"\u003cp\u003eConfigured for analog voltage signal acquisition within distributed automation architectures, the \u003cstrong\u003eAllen-Bradley 1734-IE2V\u003c\/strong\u003e (\u003cstrong\u003e1734-IE2V\u003c\/strong\u003e POINT I\/O Analog Input Module) executes precision voltage conversion at the local node level.\u003c\/p\u003e\n\u003ch3\u003eModel Cataloging and Variant Identifiers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary Catalog Number: 1734-IE2V\u003c\/li\u003e\n\u003cli\u003eAlternative Part Reference: 1734IE2V\u003c\/li\u003e\n\u003cli\u003eHardware Architecture: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eFunctional Module Class: 2-Point Non-Isolated Voltage Analog Input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IE2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2 Single-Ended Non-Isolated Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eDelta Sigma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% Full Scale @ 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eSigned Integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey Switch Position\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and Deterministic Processing\u003c\/h3\u003e\n\u003cp\u003eThe module integrates directly with the local POINTBus architecture, supporting backplane bus communication velocity parameters and firmware flash compatibility. This ensures seamless integration with host controllers across deterministic EtherNet\/IP networks, maintaining scalable I\/O density handling without control latency degradation.\u003c\/p\u003e\n\u003ch3\u003eBill of Materials and Order Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-IE2V Analog Input Module hardware assembly\u003c\/li\u003e\n\u003cli\u003e1 x Mechanical keyswitch configuration guide\u003c\/li\u003e\n\u003cli\u003e1 x Technical documentation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Deployment and Field Wiring Instructions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Securing: Mount the open-style module firmly onto a standard 35 mm industrial DIN rail inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eKey Switch Setting: Verify the physical keyswitch position is accurately set to 3 prior to base insertion.\u003c\/li\u003e\n\u003cli\u003eShielded Cabling: Terminate input signal cable shields to designated earth ground bars to mitigate ambient electrical noise.\u003c\/li\u003e\n\u003cli\u003eLoop Verification: Ensure voltage input circuits remain within non-isolated operational limits before system energization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry and System Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow many input channels does this analog module provide?\u003c\/p\u003e\n\u003cp\u003eThe module provides 2 single-ended, non-isolated voltage input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat conversion technique is utilized for analog measurements?\u003c\/p\u003e\n\u003cp\u003eThe module employs a Delta Sigma conversion architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the specified absolute accuracy of the input channels?\u003c\/p\u003e\n\u003cp\u003eThe absolute accuracy is 0.1% Full Scale at an ambient temperature of 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIn what data format are the acquired measurements processed?\u003c\/p\u003e\n\u003cp\u003eData is processed and transmitted in a Signed Integer format.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the pre-configured physical keyswitch position?\u003c\/p\u003e\n\u003cp\u003eThe physical keyswitch position is set to 3.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat enclosure rating does the hardware assembly feature?\u003c\/p\u003e\n\u003cp\u003eThe unit features an open enclosure type rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recorded weight of the individual hardware unit?\u003c\/p\u003e\n\u003cp\u003eThe module weighs 0.04 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the estimated packaging dimensions for shipping?\u003c\/p\u003e\n\u003cp\u003eThe shipping dimensions are 1.1 x 5.5 x 7.6 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399510701,"sku":"1734-IE2V","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IE2V3.jpg?v=1784731561"},{"product_id":"allen-bradley-1734-ir2-point-i-o-point-input-module","title":"Allen-Bradley 1734-IR2 Point I\/O Point Input Module","description":"\u003cp\u003eConfigured for resistance temperature detector signal acquisition in distributed automation nodes, the \u003cstrong\u003eAllen-Bradley 1734-IR2\u003c\/strong\u003e (\u003cstrong\u003e1734-IR2\u003c\/strong\u003e POINT INPUT MODULE) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Cataloging and Suffix Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Identifier: 1734-IR2\u003c\/li\u003e\n\u003cli\u003eSpare Model Reference: 1734IR2\u003c\/li\u003e\n\u003cli\u003eSeries Platform: Point I\/O\u003c\/li\u003e\n\u003cli\u003eHardware Module Class: RTD Point Input Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.6 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analogue Inputs\u003c\/td\u003e\n\u003ctd\u003e2 qty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Input Type\u003c\/td\u003e\n\u003ctd\u003eRTD \/ Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Input Range\u003c\/td\u003e\n\u003ctd\u003e0 to 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bit (signed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-75 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 k Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e1 M Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% Full Scale @ 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e120 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e100 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e30 ppm\/deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane and Deterministic Network Parameters\u003c\/h3\u003e\n\u003cp\u003eThe module executes backplane bus communication velocity parameters across compatible Allen-Bradley chassis structures. Firmware flash compatibility ensures seamless integration with contemporary controllers, supporting deterministic EtherNet\/IP networks and optimized I\/O density scaling across distributed industrial control loops.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 x 1734-IR2 Point Input Module units\u003c\/li\u003e\n\u003cli\u003e4 x Removable terminal block housing components\u003c\/li\u003e\n\u003cli\u003e2 x DIN-mounting locking latches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Deployment Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the open-style module firmly onto standard 35 mm DIN rails within a protective control cabinet.\u003c\/li\u003e\n\u003cli\u003eCold Junction Compensation: Maintain cabinet ambient temperatures within the 0 to 70 deg C range to ensure accurate thermal compensation.\u003c\/li\u003e\n\u003cli\u003eSignal Shielding: Terminate RTD sensor shields to designated ground bars to eliminate common-mode noise interference.\u003c\/li\u003e\n\u003cli\u003ePower Verification: Supply regulated 24 V DC power directly to the terminal base assembly prior to operational activation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry and Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total number of analog inputs supported by this module?\u003c\/p\u003e\n\u003cp\u003eThe module supports exactly 2 single-ended RTD input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat resolution does the analog-to-digital conversion utilize?\u003c\/p\u003e\n\u003cp\u003eThe input resolution is 16 bit signed format.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the specified resistance input range for connected sensors?\u003c\/p\u003e\n\u003cp\u003eThe input range is configured for 0 to 600 Ohm measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the common mode rejection ratio of the input circuitry?\u003c\/p\u003e\n\u003cp\u003eThe common mode rejection ratio is rated at 120 dB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the normal mode rejection ratio performance metric?\u003c\/p\u003e\n\u003cp\u003eThe normal mode rejection ratio is specified at 100 dB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the temperature coefficient drift specification?\u003c\/p\u003e\n\u003cp\u003eThe accuracy drift with temperature is 30 ppm\/deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input impedance is presented to the measurement circuit?\u003c\/p\u003e\n\u003cp\u003eThe input impedance is 100 k Ohm with an input resistance of 1 M Ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage supply powers the module bus interface?\u003c\/p\u003e\n\u003cp\u003eThe module operates on a standard 24 V DC power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399772845,"sku":"1734-IR2","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IR23_b0c47270-e2af-4de9-98ba-69aaf33c98f7.jpg?v=1784733261"},{"product_id":"1734-it2i-allen-bradley-point-i-o-2-point-thermocouple-input-module","title":"1734-IT2I Allen-Bradley POINT I\/O 2 Point Thermocouple Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-IT2I\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-IT2I\u003c\/strong\u003e POINT I\/O 2 Point Thermocouple Input, operates as a dedicated hardware component for differential temperature signal acquisition within distributed industrial control networks.\u003c\/p\u003e\n\u003ch3\u003eModel Identification and Suffix Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Identifier: 1734-IT2I\u003c\/li\u003e\n\u003cli\u003eSpare Catalog Variants: 1734IT2I, 1734-IT2I\/C\u003c\/li\u003e\n\u003cli\u003ePlatform Series: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eHardware Function: 2-Point Differential Thermocouple Input Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IT2I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 7.6 x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Bus Current Draw\u003c\/td\u003e\n\u003ctd\u003e175 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2 Differential Thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Communication and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe module facilitates high-speed data exchanges across backplane bus communication velocity frameworks within Allen-Bradley node configurations. It supports deterministic EtherNet\/IP networks, allowing seamless I\/O density scaling and complete firmware flash compatibility to match host controller revisions across modern distributed control architectures.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 x 1734-IT2I Thermocouple Input Module units\u003c\/li\u003e\n\u003cli\u003e2 x Removable terminal block bases\u003c\/li\u003e\n\u003cli\u003e1 x Technical documentation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Securely snap the open-style module onto a standard 35 mm industrial DIN rail inside an appropriate enclosure.\u003c\/li\u003e\n\u003cli\u003eThermocouple Wiring: Connect differential thermocouple leads using matched compensation extension wire to minimize thermal junction errors.\u003c\/li\u003e\n\u003cli\u003eGrounding Compliance: Terminate signal shields to designated earth ground bus bars to prevent electromagnetic susceptibility.\u003c\/li\u003e\n\u003cli\u003ePower Verification: Supply regulated 24 V DC power to the terminal base before activating the I\/O backplane communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry and System Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total current draw required from the point bus?\u003c\/p\u003e\n\u003cp\u003eThe module requires 175 mA of point bus current during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage powers the module input circuitry?\u003c\/p\u003e\n\u003cp\u003eThe module operates on a nominal 24 V DC supply voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many input channels are integrated into the hardware?\u003c\/p\u003e\n\u003cp\u003eThe hardware provides 2 differential thermocouple inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical mounting format does the module utilize?\u003c\/p\u003e\n\u003cp\u003eIt utilizes standard DIN rail mounting in an open-style chassis configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs firmware flash compatibility supported by this unit?\u003c\/p\u003e\n\u003cp\u003eYes, firmware updates are supported for integration with compatible controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are signal shields managed during field installation?\u003c\/p\u003e\n\u003cp\u003eShields must be terminated directly to designated earth ground bus bars.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific thermocouple types are processed by the inputs?\u003c\/p\u003e\n\u003cp\u003eThe channels process differential temperature inputs from standard thermocouple sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recorded weight of the individual hardware unit?\u003c\/p\u003e\n\u003cp\u003eThe unit weight is precisely 0.1 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399936685,"sku":"1734-IT2I","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IT2I_14.jpg?v=1784733074"},{"product_id":"1734-iv8-c-allen-bradley-8-channel-source-input-module-point-i-o-series","title":"1734-IV8\/C Allen-Bradley 8-Channel Source Input Module Point I\/O Series","description":"\u003cp\u003eConfigured for 24 VDC digital signal acquisition in Allen-Bradley Point I\/O systems, the \u003cstrong\u003eAllen-Bradley 1734-IV8\/C\u003c\/strong\u003e (\u003cstrong\u003e1734-IV8\/C\u003c\/strong\u003e Digital DC Sourcing Input Module) provides direct field input execution through eight source input channels.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Details\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IV8\/C is a POINT I\/O digital DC sourcing input module designed for distributed I\/O applications. The module provides eight 24 VDC input channels with a maximum input current of 5 mA per channel.\u003c\/p\u003e\n\u003cp\u003eThe module communicates through the POINTBus backplane system and requires 75 mA POINTBus current. It is designed for integration into modular POINT I\/O assemblies where distributed digital field signals are collected and transferred to the controller system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IV8\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital DC Sourcing Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 7.6 x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Maximum\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eSource Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.5 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePOINTBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.5 BTU\/hour thermal dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePoint I\/O Network Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IV8\/C applies Allen-Bradley I\/O density scaling technology within the POINT I\/O modular platform. The compact module format allows multiple digital input channels to be installed in distributed control architectures while maintaining centralized controller communication.\u003c\/p\u003e\n\u003cp\u003eThe module communicates through the POINTBus network interface, allowing input data exchange between field devices and the controller system. Proper firmware flash compatibility and adapter configuration should be verified when adding the module to an existing POINT I\/O installation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard shipment configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-IV8\/C POINT I\/O Digital DC Sourcing Input Module\u003c\/li\u003e\n\u003cli\u003e1 x Factory product identification label\u003c\/li\u003e\n\u003cli\u003e1 x Original hardware assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional components such as terminal bases, POINT I\/O adapters, mounting accessories, and network interface modules depend on the installed system configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModule Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible POINT I\/O terminal base assembly.\u003c\/li\u003e\n\u003cli\u003eVerify POINTBus power availability before module operation.\u003c\/li\u003e\n\u003cli\u003eConfirm module position and addressing within the I\/O adapter configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify 24 VDC input polarity before connecting field devices.\u003c\/li\u003e\n\u003cli\u003eSeparate signal wiring from high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding practices for control cabinet installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm controller communication settings before commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify input channel mapping in the PLC configuration software.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections before applying field power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 1734-IV8\/C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IV8\/C is an eight-channel digital DC sourcing input module used to collect 24 VDC field signals in Allen-Bradley POINT I\/O systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many input channels are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides eight independent digital input channels for connection to compatible 24 VDC field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage does the module support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is designed for 24 VDC digital input applications according to the provided technical specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the POINTBus current requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires 75 mA POINTBus current from the POINT I\/O backplane communication system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of input signals can be connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accepts discrete DC source input signals from compatible industrial field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module provide analog measurement capability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-IV8\/C is a digital input module and does not measure analog voltage or current values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation factors affect input signal quality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper wiring separation, grounding, and correct device polarity help reduce electrical interference and signal errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be installed without a POINTBus adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires a compatible POINT I\/O assembly and communication adapter for integration into the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400002221,"sku":"1734-IV8\/C","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IV8_13.jpg?v=1785121853"},{"product_id":"allen-bradley-1734-ob4-point-i-o-digital-output-module","title":"Allen-Bradley 1734-OB4 POINT I\/O Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-OB4\/C\u003c\/strong\u003e serves as the primary \u003cstrong\u003e1734-OB4\u003c\/strong\u003e Digital Output Module utilized to execute 24 VDC current sourcing switching across POINT I\/O distributed network platforms.\u003c\/p\u003e\n\u003ch3\u003eNomenclature Breakdown and Hardware Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1734-OB4: Base module configuration for 4-point digital current sourcing output\u003c\/li\u003e\n\u003cli\u003e1734OB4: Typographical standard string without separation hyphens\u003c\/li\u003e\n\u003cli\u003e1734-OB4\/C: Specific hardware manufacturing sequence denoting Series C revision\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specification Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OB4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 7.6 cm x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +55 deg C (standard operational range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic power drawn from internal POINTBus communication backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDigital current sourcing configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e4 independent output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal field power rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eOpen style DIN rail mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Network Velocity and I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module communicates via the backplane bus communication velocity framework, establishing deterministic data transfer intervals between the physical output terminals and the central processing unit. Backplane bus communication velocity handles discrete state updates within fixed scan cycles, preserving loop timing synchronization across distributed rack expansions on EtherNet\/IP deterministic networks. I\/O density scaling allows seamless integration of this 4-channel card alongside specialized analog modules without violating POINTBus current loading limits or introducing protocol conversion latencies. Firmware flash compatibility is managed through system software tools to maintain baseline operational stability across revision changes without hardware removal.\u003c\/p\u003e\n\u003ch3\u003ePackage Ordering Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OB4 Digital Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Field Wiring Base Assembly (compatible series)\u003c\/li\u003e\n\u003cli\u003e1 x Technical Hardware Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChassis and DIN Rail Mounting\n\u003cul\u003e\n\u003cli\u003ePosition the module and terminal base directly onto a 35 mm DIN rail structure within a grounded industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eSlide the unit horizontally until the locking latch engages mechanically with adjacent terminal bases to complete the backplane connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhysical Wiring Practices\n\u003cul\u003e\n\u003cli\u003eTerminate the field side 24 VDC output conductors into the removable terminal block mechanism.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage direct current output wiring paths from alternating current main lines to suppress electromagnetic interference coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Technical Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: How many discrete switching channels does this hardware module provide?\u003c\/li\u003e\n\u003cli\u003eA: The hardware incorporates 4 separate digital output channels operating in a current sourcing configuration.\u003c\/li\u003e\n\u003cli\u003eQ: What is the nominal operating voltage required for the field-side output circuits?\u003c\/li\u003e\n\u003cli\u003eA: The output channels are engineered to switch 24 VDC nominal loads in typical industrial automation control loops.\u003c\/li\u003e\n\u003cli\u003eQ: Are the field wiring connections isolated from the internal logic circuits?\u003c\/li\u003e\n\u003cli\u003eA: Yes, opto-electrical isolation is implemented to separate the field terminal voltage from the sensitive backplane logic.\u003c\/li\u003e\n\u003cli\u003eQ: Does this architecture support hot-swapping during active machine operation?\u003c\/li\u003e\n\u003cli\u003eA: The POINT I\/O backplane supports live insertion and removal, though safety protocols and area classifications must be evaluated first.\u003c\/li\u003e\n\u003cli\u003eQ: How does the unit physically secure inside the control cabinet?\u003c\/li\u003e\n\u003cli\u003eA: The component is strictly designed for physical mounting onto a standardized 35 mm DIN rail bracket.\u003c\/li\u003e\n\u003cli\u003eQ: What is the designated manufacturing origin for this specific module batch?\u003c\/li\u003e\n\u003cli\u003eA: The manufacturing origin for this hardware component is listed as Singapore.\u003c\/li\u003e\n\u003cli\u003eQ: Can this open-style module be installed directly outdoors without an enclosure?\u003c\/li\u003e\n\u003cli\u003eA: No, open-style equipment requires placement inside a dedicated cabinet providing minimum IP54 environmental ingress protection.\u003c\/li\u003e\n\u003cli\u003eQ: How is the logic circuitry powered if no direct power terminals exist on the module?\u003c\/li\u003e\n\u003cli\u003eA: Logic operating power is supplied internally through the POINTBus backplane connection managed by the system network adapter.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400100525,"sku":"1734-OB4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OB4_24.jpg?v=1785122727"},{"product_id":"1734-ob4e-allen-bradley-point-i-o-4-channel-output-module","title":"1734-OB4E Allen-Bradley Point I\/O 4 Channel Output Module","description":"\u003cp\u003eConfigured for discrete DC output execution in distributed I\/O architectures, the \u003cstrong\u003eAllen-Bradley 1734-OB4E\u003c\/strong\u003e (\u003cstrong\u003e1734OB4E\u003c\/strong\u003e 4 Channel Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eCatalog Designation \u0026amp; Series Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog Number: 1734-OB4E\u003c\/li\u003e\n\u003cli\u003eAlternate ID: 1734OB4E\u003c\/li\u003e\n\u003cli\u003eHardware Revision: 1734-OB4E\/C\u003c\/li\u003e\n\u003cli\u003eProduct Family: Point I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OB4E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.8 W max at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Backplane Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with deterministic networks via backplane bus communication velocity licenses embedded in the adapter node. It maintains high-speed I\/O density scaling across distributed drops, supporting firmware flash compatibility for seamless integration into existing control architectures. Data transfer across the backplane occurs synchronously with the master controller scan cycle.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 1734-OB4E 4 Channel Output Module\u003c\/li\u003e\n\u003cli\u003e1 Removable terminal block housing base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting and Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Securing: Mount the module vertically onto a standard 35 mm DIN rail, ensuring the locking mechanism engages securely with the rail profile.\u003c\/li\u003e\n\u003cli\u003eTerminal Termination: Strip field wiring to expose 10 mm of bare copper, inserting solid or stranded conductors directly into the spring-clamp terminal points.\u003c\/li\u003e\n\u003cli\u003eShield Grounding: Terminate cable shields to the designated functional earth ground bar to suppress electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: Does the 1734-OB4E support hot-swapping during active operation?\u003c\/li\u003e\n\u003cli\u003eA: Yes, the module supports removal and insertion under power (RIUP) when mounted on an approved terminal base unit within a grounded enclosure.\u003c\/li\u003e\n\u003cli\u003eQ: What is the nominal output voltage rating of this module?\u003c\/li\u003e\n\u003cli\u003eA: The module supplies a nominal 24 VDC output current-sourcing execution across its four discrete output channels.\u003c\/li\u003e\n\u003cli\u003eQ: How does the module handle short-circuit conditions on the outputs?\u003c\/li\u003e\n\u003cli\u003eA: Each output channel features built-in electronic protection that trips upon detecting an overcurrent event, isolating the fault independently.\u003c\/li\u003e\n\u003cli\u003eQ: What type of backplane current is required to power internal logic?\u003c\/li\u003e\n\u003cli\u003eA: Internal logic power is drawn directly from the Point I\/O backplane bus adapter at 5 VDC.\u003c\/li\u003e\n\u003cli\u003eQ: Can this module operate in hazardous industrial environments?\u003c\/li\u003e\n\u003cli\u003eA: It is rated for standard industrial environments when housed within a properly sealed NEMA or IP-rated cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003eQ: What is the maximum output current capacity per channel?\u003c\/li\u003e\n\u003cli\u003eA: Each individual channel is designed to source up to 1.0 A of continuous current at specified operating temperatures.\u003c\/li\u003e\n\u003cli\u003eQ: Are configuration parameters stored locally on the module?\u003c\/li\u003e\n\u003cli\u003eA: Configuration data is downloaded dynamically from the master PLC controller upon power-up or network reconnection.\u003c\/li\u003e\n\u003cli\u003eQ: How are channel status indicators displayed physically?\u003c\/li\u003e\n\u003cli\u003eA: Dual-color LED indicators on the front faceplate display operational status and individual channel fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400231597,"sku":"1734-OB4E","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_1734-ob4e_13.jpg?v=1785122605"},{"product_id":"allen-bradley-1734-ob8-point-i-o-digital-dc-sourcing-output-module","title":"Allen-Bradley 1734-OB8 POINT I\/O Digital DC Sourcing Output Module","description":"\u003cp\u003eConfigured for digital DC output signal execution in distributed industrial control networks, the \u003cstrong\u003eAllen-Bradley 1734-OB8\u003c\/strong\u003e (\u003cstrong\u003e1734-OB8\u003c\/strong\u003e POINT I\/O module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Architectural Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Base: 1734\u003c\/li\u003e\n\u003cli\u003eCatalog Number: OB8\u003c\/li\u003e\n\u003cli\u003eSeries Platform: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eModule Variant: Digital DC Sourcing Output\u003c\/li\u003e\n\u003cli\u003eChannel Count: 8 Outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OB8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 cm x 5.6 cm x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 W (6.8 BTU\/hour)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 V DC to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eIntegrated across Profinet and EtherNet\/IP deterministic networks, this digital output module supports backplane bus communication velocity and I\/O density scaling. The onboard processing logic manages protocol conversion latencies and ensures firmware flash compatibility, enabling synchronized control execution across distributed network nodes without introducing packet jitter or communication drops.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-OB8 Digital DC Sourcing Output Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal base connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation reference document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Clearance: Maintain adequate vertical and horizontal spacing around the module housing to allow proper convective airflow and thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the unit firmly onto a standard 35 mm industrial DIN rail, verifying that the mechanical locking mechanism engages completely.\u003c\/li\u003e\n\u003cli\u003eWiring Termination: Connect field actuator lines securely into the terminal blocks, ensuring proper conductor strip length to prevent exposed copper.\u003c\/li\u003e\n\u003cli\u003eGrounding Compliance: Fasten the base assembly directly to a grounded metal panel or mounting plate to mitigate electromagnetic interference and ensure noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module drive inductive loads directly without external suppression diodes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Inductive loads connected to sourcing outputs require flyback diodes or surge suppression networks to safely absorb magnetic kickback energy and prevent premature contact wear or internal semiconductor breakdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the POINTBus current draw affect power supply sizing in an expanded chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module draws 75 mA from the internal POINTBus, which must be factored alongside other connected cards to ensure the adapter power supply does not experience voltage sag or overload.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What troubleshooting steps are indicated when the module status indicator flashes red?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e A flashing red module status typically signals a recoverable or unrecoverable internal fault, configuration mismatch with the network scanner, or a faulted communication handshake over the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are output channels isolated from each other or grouped as a single common rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The 8 sourcing channels share common power distribution paths inside the block architecture, meaning individual channel-to-channel galvanic isolation is not present across the internal switching transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What precautions must be observed during live-insertion and removal operations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e While the POINT I\/O backplane design permits removal under power in specific non-hazardous architectures, control outputs must be forced to a safe, de-energized state first to prevent unexpected machine actuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do the yellow logic status indicators assist with diagnostic checks during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Each of the 8 yellow LEDs illuminates directly when the internal processor commands the corresponding output switch closed, allowing immediate visual verification of command logic versus field wiring state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What impact does elevated ambient cabinet temperature have on the 3 A per module current rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e High internal enclosure temperatures reduce the thermal dissipation capacity of compact electronics, potentially requiring a de-rated maximum current load to prevent thermal trip or component degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is correct key switch positioning critical prior to mounting the module onto its base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The mechanical key switch prevents accidental insertion of incompatible voltage types or module families into a wired terminal base, protecting internal circuitry from destructive over-voltage cross-wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400362669,"sku":"1734-OB8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OB8_13.jpg?v=1784728805"},{"product_id":"allen-bradley-1734-ob8e-point-i-o-series-8-point-digital-output-module","title":"Allen-Bradley 1734-OB8E POINT I\/O Series 8 Point Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-OB8E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-OB8E\u003c\/strong\u003e POINT I\/O Digital Output Module, operates as a dedicated hardware component for controlling 24 VDC discrete output signals within the Allen-Bradley POINT I\/O system. The module provides eight electronically protected DC output channels through the POINTBus communication structure.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OB8E is an 8-channel digital output module in the Allen-Bradley POINT I\/O family. It provides a single output group containing eight sourcing DC output points with electronic protection functions for industrial control applications.\u003c\/p\u003e\n\u003cp\u003eThe module communicates through the POINTBus backplane interface and receives power from the POINT I\/O adapter or terminal base assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OB8E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e8 Point Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Groups\u003c\/td\u003e\n\u003ctd\u003e1 group of 8 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e10-28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e3 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e2 A for 10 ms, repeatable every 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e75 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePOINT I\/O Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OB8E uses the Allen-Bradley POINT I\/O architecture for distributed digital output control. The module exchanges output status data through the POINTBus communication interface and supports modular I\/O density scaling within EtherNet\/IP, ControlNet, DeviceNet, and other compatible POINT I\/O adapter networks.\u003c\/p\u003e\n\u003cp\u003eThe POINT I\/O platform uses deterministic industrial communication structures to maintain consistent data transfer between controllers, communication adapters, and field I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OB8E POINT I\/O 8 Point Digital Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Digital output module assembly\u003c\/li\u003e\n\u003cli\u003e1 x Installation documentation reference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe POINT I\/O terminal base, communication adapter, power supply, and mounting accessories are not included unless specified separately.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModule Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible 1734 POINT I\/O terminal base assembly.\u003c\/li\u003e\n\u003cli\u003eVerify correct module alignment before applying insertion force.\u003c\/li\u003e\n\u003cli\u003eMount the assembly inside a suitable industrial enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse wiring suitable for the 10-28.8 VDC output range.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from high voltage AC conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConfirm load current remains within the module output rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtection and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the connected load does not exceed the specified surge current capability.\u003c\/li\u003e\n\u003cli\u003eUse appropriate cabinet grounding practices for the control system.\u003c\/li\u003e\n\u003cli\u003eConfirm the POINTBus power supply capacity before adding additional modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow many output channels are available on the 1734-OB8E?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module provides eight digital DC output channels arranged as one group containing eight outputs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat output voltage range does the module support?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1734-OB8E supports a 10-28.8 VDC output signal range with a nominal 24 VDC operating voltage.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes the module include electronic protection?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes. The module includes electronic protection for its output channels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the POINTBus current requirement?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module requires 75 mA POINTBus current from the POINT I\/O backplane system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the maximum output current capability?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module supports up to 3 A total output current per module according to the supplied specifications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan the module handle temporary surge current?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes. The module supports 2 A surge current for 10 ms with repeat operation every 3 seconds.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhich communication system does the module use?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module communicates through the Allen-Bradley POINTBus interface within the POINT I\/O platform.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs the 1734-OB8E hot-swappable?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHot-swap operation is dependent on the installed POINT I\/O adapter and system configuration. Follow the controller and adapter specifications before replacement.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400460973,"sku":"1734-OB8E","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OB8E3.jpg?v=1785121999"},{"product_id":"1734-ob8s-allen-bradley-point-i-o-series-safety-i-o-module","title":"1734-OB8S Allen-Bradley POINT I\/O Series Safety I\/O Module","description":"\u003cp\u003eConfigured for safety output switching in distributed control architectures, the \u003cstrong\u003eAllen-Bradley 1734-OB8S\u003c\/strong\u003e (\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e POINT I\/O Safety I\/O Module) provides direct electrical execution for safety-related field output devices within POINT I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-OB8S is a POINT I\/O safety output module designed for connection to safety control systems requiring distributed digital output functions. The module provides 8 output points with a 24 VDC supply requirement and supports safety-rated output switching applications.\u003c\/p\u003e\n\u003cp\u003eThe module uses the POINT I\/O modular architecture and integrates with compatible GuardLogix safety controllers through supported communication adapters.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OB8S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O 1734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafety I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e8 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.5 W maximum dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Control and Network Integration Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OB8S is designed for integration into Allen-Bradley safety control architectures using POINT I\/O distributed modules. The module supports safety output execution through compatible safety controllers and network adapters.\u003c\/p\u003e\n\u003cp\u003eThe POINT I\/O platform provides I\/O density scaling for compact control cabinet layouts. EtherNet\/IP based deterministic networks can be used when the module is installed with compatible communication interfaces.\u003c\/p\u003e\n\u003cp\u003eSafety configuration, controller firmware compatibility, and network adapter revision must match the requirements of the installed safety system. The module operates as part of a configured safety solution rather than as an independent safety controller.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OB8S POINT I\/O Safety I\/O Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional POINT I\/O components required for installation may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOINT I\/O terminal base assembly\u003c\/li\u003e\n\u003cli\u003eCompatible POINT I\/O communication adapter\u003c\/li\u003e\n\u003cli\u003eSafety controller with supported configuration software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible POINT I\/O terminal base.\u003c\/li\u003e\n\u003cli\u003eVerify terminal base and module alignment before applying power.\u003c\/li\u003e\n\u003cli\u003eMount the module in an enclosure suitable for the installation environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect field safety outputs according to the approved system wiring design.\u003c\/li\u003e\n\u003cli\u003eVerify 24 VDC supply polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eSeparate safety signal wiring from high-energy power circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConfiguration and Commissioning\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm controller firmware compatibility before downloading safety configuration.\u003c\/li\u003e\n\u003cli\u003eVerify module status indicators during commissioning.\u003c\/li\u003e\n\u003cli\u003eValidate safety output operation according to the machine safety design procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFirmware and Safety Architecture Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OB8S operates within the Allen-Bradley POINT I\/O safety ecosystem and requires compatible safety controllers and configuration tools.\u003c\/p\u003e\n\u003cp\u003eThe module participates in safety output execution through configured safety logic. Communication performance depends on the selected network adapter, controller processing capability, and system architecture.\u003c\/p\u003e\n\u003cp\u003eFirmware compatibility between the module, safety controller, and communication adapter must be verified before system deployment or replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of module is the 1734-OB8S?\u003c\/p\u003e\n\u003cp\u003eThe 1734-OB8S is a POINT I\/O safety output module designed for safety-related digital output applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many output points are available?\u003c\/p\u003e\n\u003cp\u003eThe module provides 8 safety output points for connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage does the module require?\u003c\/p\u003e\n\u003cp\u003eThe module operates with a 24 VDC supply voltage according to the provided specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module operate as a standalone safety controller?\u003c\/p\u003e\n\u003cp\u003eNo. The module requires integration with a compatible Allen-Bradley safety controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the module installed directly on a communication network?\u003c\/p\u003e\n\u003cp\u003eThe module connects through a POINT I\/O adapter that provides communication with the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat affects safety output operation?\u003c\/p\u003e\n\u003cp\u003eController configuration, firmware compatibility, wiring design, and network communication affect operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require a terminal base assembly?\u003c\/p\u003e\n\u003cp\u003eYes. The POINT I\/O module requires a compatible terminal base for electrical connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat installation practice is recommended for safety wiring?\u003c\/p\u003e\n\u003cp\u003eSafety wiring should follow the approved machine design and maintain separation from power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400559277,"sku":"1734-OB8S","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OB8S.jpg?v=1785123940"},{"product_id":"1734-oe2v-allen-bradley-point-i-o-series-analog-output-module","title":"1734-OE2V Allen-Bradley POINT I\/O Series Analog Output Module","description":"\u003cp\u003eConfigured for voltage signal generation in EtherNet\/IP based industrial control architectures, the \u003cstrong\u003eAllen-Bradley 1734-OE2V\u003c\/strong\u003e (\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e POINT I\/O Analog Output Module) provides direct digital-to-analog execution for field output devices.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-OE2V is a POINT I\/O analog output module providing two single-ended, non-isolated voltage outputs. The module converts controller data values into analog voltage signals for connected field devices.\u003c\/p\u003e\n\u003cp\u003eThe module supports 0 to 10 V output range, 14-bit resolution, signed integer data formatting, and a digital-to-analog conversion rate of 20 microseconds.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OE2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 Single-Ended Non-Isolated Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Load\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eDigital-to-Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Rate\u003c\/td\u003e\n\u003ctd\u003e20 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eSigned Integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and I\/O Scaling Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OE2V operates within the Allen-Bradley POINT I\/O platform and integrates into distributed I\/O architectures through compatible POINT I\/O communication adapters.\u003c\/p\u003e\n\u003cp\u003eThe module supports I\/O density scaling by allowing compact installation of analog output channels in remote control locations. Controller output data is transferred through the POINT I\/O communication interface and converted into proportional voltage signals.\u003c\/p\u003e\n\u003cp\u003eThe module architecture supports deterministic industrial networks such as EtherNet\/IP when installed with compatible POINT I\/O network adapters. Firmware compatibility and adapter configuration must match the installed control system requirements.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OE2V POINT I\/O Analog Output Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional POINT I\/O components required for operation may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOINT I\/O terminal base assembly\u003c\/li\u003e\n\u003cli\u003eCompatible POINT I\/O communication adapter\u003c\/li\u003e\n\u003cli\u003eController-side configuration software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eModule Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible POINT I\/O terminal base.\u003c\/li\u003e\n\u003cli\u003eVerify terminal base compatibility before applying power.\u003c\/li\u003e\n\u003cli\u003eConfirm correct module position within the POINT I\/O assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWiring Requirements\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect analog voltage outputs according to the field device requirements.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded wiring practices for analog signal circuits.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-current power conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConfiguration Setup\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfigure output range and scaling parameters in the controller software.\u003c\/li\u003e\n\u003cli\u003eVerify signed integer output values correspond with required field voltage levels.\u003c\/li\u003e\n\u003cli\u003eCheck channel status indicators during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFirmware and Communication Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OE2V uses the POINT I\/O modular architecture for distributed analog output control. Communication behavior depends on the installed POINT I\/O adapter and controller network configuration.\u003c\/p\u003e\n\u003cp\u003eThe module does not provide isolated outputs, therefore field wiring design must consider grounding methods and signal reference requirements. Proper configuration ensures correct conversion between controller data values and analog output voltage levels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow many analog outputs are available on the 1734-OE2V?\u003c\/p\u003e\n\u003cp\u003eThe module provides 2 single-ended, non-isolated analog voltage output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage range does this module support?\u003c\/p\u003e\n\u003cp\u003eThe module supports a 0 to 10 V analog output range for connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the output channel electrically isolated?\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-OE2V provides non-isolated single-ended voltage outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of conversion does the module perform?\u003c\/p\u003e\n\u003cp\u003eThe module performs digital-to-analog conversion from controller data values to voltage signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat data format is used by this module?\u003c\/p\u003e\n\u003cp\u003eThe module uses signed integer data formatting for analog output values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the module resolution?\u003c\/p\u003e\n\u003cp\u003eThe analog output resolution is 14 bits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module operate without a POINT I\/O terminal base?\u003c\/p\u003e\n\u003cp\u003eNo. The module requires installation on a compatible POINT I\/O terminal base assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat affects analog output signal accuracy?\u003c\/p\u003e\n\u003cp\u003eSignal wiring, grounding, controller scaling, and connected device characteristics affect output accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400755885,"sku":"1734-OE2V","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OE2V_1.jpg?v=1785123799"},{"product_id":"1734-oe4c-allen-bradley-analog-output-module-point-i-o","title":"1734-OE4C Allen-Bradley Analog Output Module POINT I\/O","description":"\u003cp\u003eConfigured for multi-channel analog signal generation in distributed control frameworks, the \u003cstrong\u003eAllen-Bradley 1734-OE4C\u003c\/strong\u003e (\u003cstrong\u003e1734-OE4C\u003c\/strong\u003e POINT I\/O Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eCatalog Designation \u0026amp; Series Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog Number: 1734-OE4C\u003c\/li\u003e\n\u003cli\u003eProduct Series: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eModule Classification: Analog Output Module\u003c\/li\u003e\n\u003cli\u003eData Format: Signed Integer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OE4C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eExternal DC Supply Current 220 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA, 0 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Architecture and Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe module relies on backplane bus communication velocity licenses to interface seamlessly with adapter nodes across distributed architectures. It maintains strict I\/O density scaling profiles, enabling deterministic data updates while supporting firmware flash compatibility for seamless integration into standard EtherNet\/IP control loops.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 1734-OE4C Analog Output Module\u003c\/li\u003e\n\u003cli\u003e1 Removable terminal block base unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mounting and Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRail Alignment: Secure the module onto a standard 35 mm DIN rail, ensuring the mechanical latch locks firmly against the profile.\u003c\/li\u003e\n\u003cli\u003eCable Shielding: Terminate all analog signal cable shields to the designated functional earth ground to minimize high-frequency noise coupling.\u003c\/li\u003e\n\u003cli\u003eConductor Strip Length: Strip field wiring insulation to expose 10 mm of bare copper for insertion into spring-clamp terminal points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: Does the 1734-OE4C support hot-swapping during active operation?\u003c\/li\u003e\n\u003cli\u003eA: Yes, the module supports removal and insertion under power (RIUP) when installed on an approved terminal base within a grounded enclosure.\u003c\/li\u003e\n\u003cli\u003eQ: What conversion type and rate does the module utilize?\u003c\/li\u003e\n\u003cli\u003eA: The module performs digital-to-analog conversion at a conversion rate of 20 microseconds across its four single-ended output channels.\u003c\/li\u003e\n\u003cli\u003eQ: What is the output resolution specification?\u003c\/li\u003e\n\u003cli\u003eA: It provides 16 bits of resolution across 0 to 21 mA with an internal data conversion format of signed integer values.\u003c\/li\u003e\n\u003cli\u003eQ: How does the module receive external operating power?\u003c\/li\u003e\n\u003cli\u003eA: Operating power is supplied via an external DC supply providing up to 220 mA to drive the loop channels safely.\u003c\/li\u003e\n\u003cli\u003eQ: Can this module drive both 4 to 20 mA and 0 to 20 mA loops?\u003c\/li\u003e\n\u003cli\u003eA: Yes, the output signal range is software configurable to support either 4 to 20 mA or 0 to 20 mA field loops.\u003c\/li\u003e\n\u003cli\u003eQ: What backplane current is consumed for internal logic functions?\u003c\/li\u003e\n\u003cli\u003eA: Internal logic circuitry draws power directly from the POINT I\/O adapter backplane bus interface.\u003c\/li\u003e\n\u003cli\u003eQ: Are the individual output channels galvanically isolated from each other?\u003c\/li\u003e\n\u003cli\u003eA: Outputs are single-ended and referenced to a common ground point within the module circuitry architecture.\u003c\/li\u003e\n\u003cli\u003eQ: How are operational faults indicated on the hardware?\u003c\/li\u003e\n\u003cli\u003eA: Diagnostic status is communicated via front-panel LED indicators displaying channel activity and communication health.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400854189,"sku":"1734-OE4C","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OE4C_14.jpg?v=1785122505"},{"product_id":"1734-ov2e-allen-bradley-point-i-o-digital-dc-sinking-output-module","title":"1734-OV2E Allen-Bradley POINT I\/O Digital DC Sinking Output Module","description":"\u003cp\u003eConfigured for 24 VDC sinking output execution in industrial logic controllers, the \u003cstrong\u003eAllen-Bradley 1734-OV2E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-OV2E\u003c\/strong\u003e Digital DC Sinking Output Module, provides direct physical and electrical switching.\u003c\/p\u003e\n\u003ch3\u003eNomenclature Breakdown and Hardware Mapping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1734-OV2E: Base catalog number for the 2-point digital DC sinking output hardware\u003c\/li\u003e\n\u003cli\u003ePOINT I\/O: Modular distributed I\/O platform architecture classification\u003c\/li\u003e\n\u003cli\u003eDigital DC Sinking Output Module: Functional designation for negative-switching DC logic signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specification Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OV2E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.3 cm x 7.6 cm x 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.8 Watts power dissipation (2.7 BTU\/hour thermal dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e2 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Protection\u003c\/td\u003e\n\u003ctd\u003eYes (electronically protected outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e75 milliamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e2 amps per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly through the backplane bus communication velocity framework, establishing deterministic data transfer intervals between the physical terminals and the central processing unit. Backplane bus communication velocity handles discrete state updates within fixed scan cycles, preserving loop timing synchronization across distributed rack expansions. I\/O density scaling allows seamless integration alongside specialized analog and communication modules without violating backplane current loading limits or introducing protocol conversion latencies. Firmware flash compatibility is managed through system software tools to maintain baseline operational stability across revision changes.\u003c\/p\u003e\n\u003ch3\u003ePackage Ordering Inventory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OV2E Digital DC Sinking Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Removable Terminal Base Connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical Hardware Reference Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting\n\u003cul\u003e\n\u003cli\u003ePosition the terminal base and module housing directly onto a standard 35 mm industrial DIN rail inside a protective control enclosure.\u003c\/li\u003e\n\u003cli\u003ePress the unit downward until the locking mechanism engages securely with the rail surface and adjacent communication bus connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eField Wiring Terminations\n\u003cul\u003e\n\u003cli\u003eTerminate external 24 VDC load conductors into the designated screw or spring-clamp terminal connections.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage DC output wiring away from high-voltage power lines to minimize electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Technical Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: How many discrete switching channels does this hardware module feature?\u003c\/li\u003e\n\u003cli\u003eA: The module features 2 digital DC sinking output channels.\u003c\/li\u003e\n\u003cli\u003eQ: What is the designated nominal output voltage for the switching points?\u003c\/li\u003e\n\u003cli\u003eA: The output voltage is rated at 24 Volts DC.\u003c\/li\u003e\n\u003cli\u003eQ: What is the total output current rating for the module?\u003c\/li\u003e\n\u003cli\u003eA: The module provides an aggregate output current rating of 2 amps.\u003c\/li\u003e\n\u003cli\u003eQ: How much current does the unit draw from the internal POINTBus?\u003c\/li\u003e\n\u003cli\u003eA: The POINTBus current consumption is 75 milliamps.\u003c\/li\u003e\n\u003cli\u003eQ: What are the power and thermal dissipation values under operation?\u003c\/li\u003e\n\u003cli\u003eA: The power dissipation is 0.8 Watts, producing a thermal dissipation of 2.7 BTU per hour.\u003c\/li\u003e\n\u003cli\u003eQ: Are the output channels protected against electrical faults?\u003c\/li\u003e\n\u003cli\u003eA: Yes, the output channels are electronically protected.\u003c\/li\u003e\n\u003cli\u003eQ: Does this architecture permit live hot-swapping inside an active rack?\u003c\/li\u003e\n\u003cli\u003eA: System power must be isolated prior to inserting or removing modules to prevent electrical arcing on the bus.\u003c\/li\u003e\n\u003cli\u003eQ: What tariff code is assigned to this hardware component for shipping?\u003c\/li\u003e\n\u003cli\u003eA: The assigned tariff code is 8537101190.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400952493,"sku":"1734-OV2E","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OV2E_1_664b2be6-ea42-4037-8221-2631a46530b6.jpg?v=1785123590"},{"product_id":"1734-ov4e-allen-bradley-digital-dc-sinking-output-module-point-i-o","title":"1734-OV4E Allen-Bradley Digital DC Sinking Output Module POINT I\/O","description":"\u003cp\u003eConfigured for 24 VDC sinking output execution in industrial logic controllers, the \u003cstrong\u003eAllen-Bradley 1734-OV4E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-OV4E\u003c\/strong\u003e Output Module, provides direct physical and electrical switching.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Part Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1734-OV4E: Base catalog number for the 4-point digital sinking DC output module\u003c\/li\u003e\n\u003cli\u003ePOINT I\/O: Modular distributed I\/O platform classification\u003c\/li\u003e\n\u003cli\u003eOpen Style: Unenclosed module design intended for DIN rail mounted enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications Table\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OV4E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 cm x 6 cm x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.2 W power dissipation (4.1 BTU\/hour thermal dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e4 points sinking 24 VDC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e3 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe module communicates via the backplane bus communication velocity framework, establishing deterministic data transfer intervals between the physical terminals and the central processing unit. Backplane bus communication velocity handles discrete state updates within fixed scan cycles, preserving loop timing synchronization across distributed rack expansions. I\/O density scaling allows seamless integration alongside specialized analog and communication modules without violating backplane current loading limits or introducing protocol conversion latencies. Firmware flash compatibility is managed through system software tools to maintain baseline operational stability across revision changes.\u003c\/p\u003e\n\u003ch3\u003eShipment Contents \u0026amp; Package Inventory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OV4E Digital DC Sinking Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Removable Terminal Block Insert\u003c\/li\u003e\n\u003cli\u003e1 x Technical Hardware Reference Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting\n\u003cul\u003e\n\u003cli\u003eMount the module base securely onto a standard 35 mm industrial DIN rail inside an approved electrical cabinet.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the terminal base and snap firmly into position to engage the communication backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eField Wiring Connections\n\u003cul\u003e\n\u003cli\u003eTerminate external 24 VDC load lines directly into the removable terminal block screw connections.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage output wiring away from high-voltage AC power cables to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Technical Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: How many output points does this module control?\u003c\/li\u003e\n\u003cli\u003eA: The module provides 4 digital DC sinking output points.\u003c\/li\u003e\n\u003cli\u003eQ: What is the rated output voltage for the switching channels?\u003c\/li\u003e\n\u003cli\u003eA: The output voltage is rated at 24 Volts DC.\u003c\/li\u003e\n\u003cli\u003eQ: What is the maximum output current capacity per module?\u003c\/li\u003e\n\u003cli\u003eA: The total module output current rating is 3 amps.\u003c\/li\u003e\n\u003cli\u003eQ: How much current does the unit draw from the POINTBus?\u003c\/li\u003e\n\u003cli\u003eA: The POINTBus current draw is 75 milliamps.\u003c\/li\u003e\n\u003cli\u003eQ: What are the thermal and power dissipation values?\u003c\/li\u003e\n\u003cli\u003eA: Power dissipation is 1.2 Watts, resulting in a thermal dissipation of 4.1 BTU per hour.\u003c\/li\u003e\n\u003cli\u003eQ: Are the outputs electronically protected against faults?\u003c\/li\u003e\n\u003cli\u003eA: Yes, the module features built-in electronic protection for safe operation.\u003c\/li\u003e\n\u003cli\u003eQ: Does this module support live hot-swapping inside an active rack?\u003c\/li\u003e\n\u003cli\u003eA: System power must be isolated before removing or inserting modules to prevent bus arc damage.\u003c\/li\u003e\n\u003cli\u003eQ: What physical dimensions apply to the shipping container?\u003c\/li\u003e\n\u003cli\u003eA: The estimated shipping dimensions measure 8 cm x 6 cm x 1.7 cm.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066401018029,"sku":"1734-OV4E","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OV4E3_1_3.jpg?v=1785138258"},{"product_id":"1734-ov8e-allen-bradley-digital-dc-sinking-output-module-point-i-o","title":"1734-OV8E Allen-Bradley Digital DC Sinking Output Module POINT I\/O","description":"\u003cp\u003eDesigned for compact spatial footprints within distributed automation racks, the \u003cstrong\u003eAllen-Bradley 1734-OV8E\u003c\/strong\u003e (\u003cstrong\u003e1734-OV8E\u003c\/strong\u003e) Digital DC Sinking Output Module executes discrete switching commands through solid-state semiconductor switches.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Layout \u0026amp; Part Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform Family\u003c\/strong\u003e: Allen-Bradley POINT I\/O modular terminal infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Designation\u003c\/strong\u003e: 1734-OV8E specifying an 8-channel sinking output configuration equipped with active electronic fault sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Circuitry\u003c\/strong\u003e: Optically isolated switching transistors, backplane interface transceivers, and onboard diagnostic logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OV8E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 discrete sinking outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current\u003c\/td\u003e\n\u003ctd\u003e3 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Draw\u003c\/td\u003e\n\u003ctd\u003e75 mA (POINTBus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration \u0026amp; Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe module communicates state data across the local POINTBus architecture, interfacing smoothly with higher-level controllers via backplane bus communication velocity licences. Firmware flash compatibility ensures that operational updates integrate cleanly without breaking deterministic network timing. Furthermore, input\/output density scaling allows system expansion without introducing communication delays or processing bottlenecks.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OV8E Digital DC Sinking Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Mechanical locking latch clip\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation reference leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Field Wiring Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal Base Engagement: Snap the module vertically onto an approved 1734 terminal base mounted on a grounded DIN rail, confirming positive physical latching.\u003c\/li\u003e\n\u003cli\u003eConductor Termination: Secure field actuator wires directly into the terminal base spring-clamp connections, maintaining strip lengths specified by the manufacturer.\u003c\/li\u003e\n\u003cli\u003eTransient Suppression: Install appropriate flyback diodes across inductive DC loads connected to the sinking outputs to suppress voltage spikes and protect internal semiconductor gates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Engineering Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the electronic short-circuit protection mechanism handle sustained overloads on individual sinking channels?\u003c\/p\u003e\n\u003cp\u003eA: When an overcurrent or short-circuit event trips on a channel, the internal electronic protection latches the output off to prevent thermal runaway, reporting the fault status back to the controller via backplane diagnostic registers until cleared by a command reset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the propagation delay time from the assertion of the POINTBus backplane command to the physical state transition of the solid-state output switch?\u003c\/p\u003e\n\u003cp\u003eA: The hardware turn-on and turn-off propagation delays are optimized within sub-millisecond tolerances to ensure high-speed deterministic performance for fast-cycling pneumatic valves or electronic relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can these sinking outputs be wired in parallel to aggregate higher current capacity for a single heavy DC load?\u003c\/p\u003e\n\u003cp\u003eA: Parallel wiring of solid-state sinking outputs is not recommended due to slight micro-variations in switching propagation speeds, which can cause transient current-hogging and thermal overload on the faster-responding channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the optical isolation barrier between the field side and the POINTBus backplane behave during common-mode voltage transients?\u003c\/p\u003e\n\u003cp\u003eA: The internal optocouplers provide high dielectric separation, effectively preventing high-frequency ground loops, electromagnetic noise, and common-mode voltage surges from transferring into the sensitive internal logic plane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What occurs to the field output state if communication over the POINTBus backplane is abruptly lost due to a network fault?\u003c\/p\u003e\n\u003cp\u003eA: The module transitions all output channels to predefined user-configured safe states (hold-last-state or forced-off) determined during the initial controller configuration profile to maintain fail-safe plant operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are the electronic protection flags mapped directly into the controller input data table for real-time diagnostic polling?\u003c\/p\u003e\n\u003cp\u003eA: Yes, module-defined status bits transmit fault conditions directly to the controller memory map, allowing automated alarm generation and rapid troubleshooting without manual multimeter tracing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does thermal derating affect the aggregate 3 A module current limit when operating at the maximum ambient temperature boundary of +55 deg C?\u003c\/p\u003e\n\u003cp\u003eA: While the module functions up to +55 deg C, continuous maximum load profiles must account for internal power dissipation to avoid triggering internal thermal shutdown thresholds, particularly in tight unventilated enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What specific considerations must be applied when driving high-inductance DC solenoids to prevent premature degradation of the output transistors?\u003c\/p\u003e\n\u003cp\u003eA: Inductive loads must include external freewheeling flyback diodes connected as close to the load terminals as possible to safely dissipate stored magnetic energy and protect the internal solid-state switches from repetitive inductive voltage kickback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066401083565,"sku":"1734-OV8E","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-ov8e_17.jpg?v=1785122858"},{"product_id":"1734-ssi-allen-bradley-ssi-module-point-i-o-series","title":"1734-SSI Allen-Bradley SSI Module POINT I\/O Series","description":"\u003cp\u003eConfigured for serial synchronous encoder data acquisition in POINT I\/O systems, the \u003cstrong\u003eAllen-Bradley 1734-SSI\u003c\/strong\u003e (\u003cstrong\u003e1734-SSI\u003c\/strong\u003e SSI Module) provides direct physical\/electrical execution through a single SSI communication channel.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1734-SSI is a Serial Synchronous Interface module designed for Allen-Bradley POINT I\/O architecture. The module provides one SSI communication port for connecting SSI-compatible absolute position devices and transferring synchronous serial data through the POINTBus network.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1734-SSI\u003c\/td\u003e\n\u003ctd\u003eSerial Synchronous Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley POINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eSSI Serial Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSI Channels\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-SSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSSI Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.94 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e110 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSI Channels\u003c\/td\u003e\n\u003ctd\u003e1 SSI port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eSerial Synchronous Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O modular mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and POINTBus Data Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1734-SSI operates as a POINT I\/O communication module within distributed I\/O systems. The module exchanges SSI device data through the POINTBus backplane while maintaining modular I\/O expansion capability.\u003c\/p\u003e\n\u003cp\u003eThe Allen-Bradley POINT I\/O platform uses deterministic industrial communication methods for controller integration. Module configuration parameters are stored through the controller software environment and depend on the selected network adapter and controller architecture.\u003c\/p\u003e\n\u003ch3\u003eFirmware and I\/O Configuration Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module configuration requires matching firmware compatibility between the POINT I\/O adapter, controller system, and installed I\/O modules. Firmware flash compatibility should be verified before replacing modules in an active control architecture.\u003c\/p\u003e\n\u003cp\u003eThe 1734-SSI supports I\/O density scaling through POINT I\/O modular installation, allowing additional modules to be added according to system architecture requirements.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe supplied configuration normally includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-SSI SSI Module\u003c\/li\u003e\n\u003cli\u003e1 x POINT I\/O module housing assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional components required for operation may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOINT I\/O terminal base\u003c\/li\u003e\n\u003cli\u003eCompatible POINT I\/O adapter module\u003c\/li\u003e\n\u003cli\u003eController communication interface\u003c\/li\u003e\n\u003cli\u003eSSI field device wiring accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible POINT I\/O terminal base.\u003c\/li\u003e\n\u003cli\u003eConfirm module seating before applying system power.\u003c\/li\u003e\n\u003cli\u003eMaintain enclosure protection suitable for the installation environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSSI Signal Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse wiring suitable for serial synchronous communication signals.\u003c\/li\u003e\n\u003cli\u003eKeep SSI communication wiring separated from high voltage conductors.\u003c\/li\u003e\n\u003cli\u003eApply proper cable shielding and grounding practices where electrical interference exists.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSystem Commissioning\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify SSI device parameters before enabling data exchange.\u003c\/li\u003e\n\u003cli\u003eConfirm controller recognition of the module after installation.\u003c\/li\u003e\n\u003cli\u003eCheck communication status indicators during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat communication interface does the 1734-SSI support?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module supports Serial Synchronous Interface communication for SSI-compatible devices requiring synchronous serial data transfer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHow many SSI channels are available?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1734-SSI provides one dedicated SSI communication channel through the POINT I\/O module structure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat supply voltage range is supported?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module operates with a supply voltage range of 10 to 28.8 VDC according to the provided technical specifications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the POINTBus current requirement?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module requires 110 mA of POINTBus current during operation within the POINT I\/O system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the operating temperature range?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified operating temperature range is -20 to 55 deg C for normal module operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan the module be installed without a POINT I\/O terminal base?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The module requires a compatible POINT I\/O terminal base for mechanical mounting and electrical connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDoes the module support multiple SSI devices simultaneously?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The hardware configuration provides one SSI communication port for a single SSI device connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat installation practices affect SSI signal quality?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProper shielding, grounding, cable routing, and separation from electrical noise sources affect SSI communication stability.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066401345709,"sku":"1734-SSI","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-SSI_1.jpg?v=1785124504"},{"product_id":"1794-acn15-allen-bradley-communication-adapter-flex-i-o","title":"1794-ACN15 Allen-Bradley Communication Adapter FLEX I\/O","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-ACN15\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-ACN15\u003c\/strong\u003e Flex I\/O communication adapter, operates as a dedicated hardware component for ControlNet network interfacing within FLEX I\/O platforms. The module manages the physical layer conversion and cyclic data transfer protocols between the high-speed ControlNet coax media and the localized backplane bus. It functions as the remote node manager, sequencing up to eight connected I\/O terminal bases without inserting processing degradation into the digital or analog control loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature and Hardware Series\u003c\/h3\u003e\n\u003cp\u003eThe primary catalog identifier defines the basic physical interface configuration, while the sequential letter suffixes track hardware modifications. The baseline alphanumeric configuration designates a standard ControlNet non-redundant media interface operating via BNC coax terminations. Suffix identifiers such as \/A, \/B, \/C, and \/D mark specific production revisions, governing internal component updates and matching firmware flash compatibility rules across different processor revision levels.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-ACN15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.4x8.7x6.9cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupported by 24 VDC external source input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexbus Output Current\u003c\/td\u003e\n\u003ctd\u003e640 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e850 VDC between network and logic circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 open-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail tracking layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Data Routing\u003c\/h3\u003e\n\u003cp\u003eThis module governs the local I\/O density scaling capacity by executing predictable data transfers across the internal bus structure. The unit enforces backplane bus communication velocity Licences protocols to maintain timed updates between the controller image and the remote physical channels. It structures synchronous communication frames across the backplane loop, ensuring deterministic behavior over industrial control networks while avoiding data corruption when handling combinations of high-density discrete and analog sub-modules.\u003c\/p\u003e\n\u003ch3\u003ePackage Component Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-ACN15 adapter hardware unit\u003c\/li\u003e\n\u003cli\u003e1 x installation instruction document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Attachment Strategy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHook the upper slot of the adapter base onto the top of the DIN rail, then pivot the module downward until the zinc-plated locking spring snaps securely onto the tracking line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Coaxial Connection Matrix\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the internal pins of the BNC connector with the dual slots of the ControlNet tap cable plug, press firmly together, and twist the outer ring 90 degrees clockwise to engage the lock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Termination Steps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute 24 VDC wires into the designated positive and negative terminal clamp positions, tightening the set screws to prevent local impedance variations or power failure states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSub-module Interlock Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlide the adjacent terminal base firmly along the side grooves of the adapter housing to ensure the internal multi-pin backplane bus header seats parallel with zero pin deflection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific limitations govern the hot-swap capability of this module while the backplane loop is energized?\u003c\/p\u003e\n\u003cp\u003eThe communication adapter cannot be removed while the system is under power. Removing the adapter opens the local backplane loop, immediately faulting all downstream I\/O bases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the maximum Flexbus current limit restrict the number of modules attached to this adapter?\u003c\/p\u003e\n\u003cp\u003eThe internal power regulator delivers up to 640 mA. The combined logic current draw of all connected modules must not exceed this value, or the adapter will shut down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure signature indicates that the module has dropped offline due to a network configuration mismatch?\u003c\/p\u003e\n\u003cp\u003eA data mismatch causes the status indicators to flash red or amber, and the master controller logs an I\/O configuration fault, freezing current output states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific unit support media redundancy configuration using dual trunk lines?\u003c\/p\u003e\n\u003cp\u003eNo. The standard non-redundant configuration features a single network BNC connector port, requiring a single path connection layout rather than the dual-port redundancy setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the ControlNet station node address mechanically assigned on the hardware interface?\u003c\/p\u003e\n\u003cp\u003eThe address is configured using two rotary switches located on the front face of the enclosure, allowing values between 01 and 99 to be indexed prior to mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat step is required to address a flash memory conflict when matching components with older processors?\u003c\/p\u003e\n\u003cp\u003eThe adapter version must match the electronic keying in the controller software, requiring a firmware update via the control network if revision incompatibility is flagged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the isolation path between the communication link and the 24 VDC input circuit fused?\u003c\/p\u003e\n\u003cp\u003eThe 850 VDC isolation is achieved via internal optocouplers and transformers. The 24 VDC power terminals require external current-limiting fuses to prevent hardware degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this adapter operate within environments where industrial moisture condensation is present?\u003c\/p\u003e\n\u003cp\u003eNo. The open-style IP20 housing lacks moisture seals, requiring installation within a climate-controlled enclosure that maintains non-condensing relative humidity conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066455838893,"sku":"1794-ACN15","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-ACN15_25.jpg?v=1784509054"},{"product_id":"allen-bradley-flex-i-o-1794-acnr15-flex-controlnet-adapter","title":"Allen-Bradley FLEX I\/O 1794-ACNR15 Flex Controlnet Adapter","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-ACN15\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-ACN15\u003c\/strong\u003e Flex I\/O communication adapter, operates as a dedicated hardware component for ControlNet network interfacing within FLEX I\/O platforms. The module manages the physical layer conversion and cyclic data transfer protocols between the high-speed ControlNet coax media and the localized backplane bus. It functions as the remote node manager, sequencing up to eight connected I\/O terminal bases without inserting processing degradation into the digital or analog control loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature and Hardware Series\u003c\/h3\u003e\n\u003cp\u003eThe primary catalog identifier defines the basic physical interface configuration, while the sequential letter suffixes track hardware modifications. The baseline alphanumeric configuration designates a standard ControlNet non-redundant media interface operating via BNC coax terminations. Suffix identifiers such as \/A, \/B, \/C, and \/D mark specific production revisions, governing internal component updates and matching firmware flash compatibility rules across different processor revision levels.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-ACN15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.4x8.7x6.9cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupported by 24 VDC external source input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexbus Output Current\u003c\/td\u003e\n\u003ctd\u003e640 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e850 VDC between network and logic circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 open-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail tracking layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Data Routing\u003c\/h3\u003e\n\u003cp\u003eThis module governs the local I\/O density scaling capacity by executing predictable data transfers across the internal bus structure. The unit enforces backplane bus communication velocity Licences protocols to maintain timed updates between the controller image and the remote physical channels. It structures synchronous communication frames across the backplane loop, ensuring deterministic behavior over industrial control networks while avoiding data corruption when handling combinations of high-density discrete and analog sub-modules.\u003c\/p\u003e\n\u003ch3\u003ePackage Component Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-ACN15 adapter hardware unit\u003c\/li\u003e\n\u003cli\u003e1 x installation instruction document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Attachment Strategy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHook the upper slot of the adapter base onto the top of the DIN rail, then pivot the module downward until the zinc-plated locking spring snaps securely onto the tracking line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Coaxial Connection Matrix\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the internal pins of the BNC connector with the dual slots of the ControlNet tap cable plug, press firmly together, and twist the outer ring 90 degrees clockwise to engage the lock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Termination Steps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute 24 VDC wires into the designated positive and negative terminal clamp positions, tightening the set screws to prevent local impedance variations or power failure states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSub-module Interlock Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlide the adjacent terminal base firmly along the side grooves of the adapter housing to ensure the internal multi-pin backplane bus header seats parallel with zero pin deflection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific limitations govern the hot-swap capability of this module while the backplane loop is energized?\u003c\/p\u003e\n\u003cp\u003eThe communication adapter cannot be removed while the system is under power. Removing the adapter opens the local backplane loop, immediately faulting all downstream I\/O bases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the maximum Flexbus current limit restrict the number of modules attached to this adapter?\u003c\/p\u003e\n\u003cp\u003eThe internal power regulator delivers up to 640 mA. The combined logic current draw of all connected modules must not exceed this value, or the adapter will shut down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure signature indicates that the module has dropped offline due to a network configuration mismatch?\u003c\/p\u003e\n\u003cp\u003eA data mismatch causes the status indicators to flash red or amber, and the master controller logs an I\/O configuration fault, freezing current output states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific unit support media redundancy configuration using dual trunk lines?\u003c\/p\u003e\n\u003cp\u003eNo. The standard non-redundant configuration features a single network BNC connector port, requiring a single path connection layout rather than the dual-port redundancy setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the ControlNet station node address mechanically assigned on the hardware interface?\u003c\/p\u003e\n\u003cp\u003eThe address is configured using two rotary switches located on the front face of the enclosure, allowing values between 01 and 99 to be indexed prior to mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat step is required to address a flash memory conflict when matching components with older processors?\u003c\/p\u003e\n\u003cp\u003eThe adapter version must match the electronic keying in the controller software, requiring a firmware update via the control network if revision incompatibility is flagged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the isolation path between the communication link and the 24 VDC input circuit fused?\u003c\/p\u003e\n\u003cp\u003eThe 850 VDC isolation is achieved via internal optocouplers and transformers. The 24 VDC power terminals require external current-limiting fuses to prevent hardware degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this adapter operate within environments where industrial moisture condensation is present?\u003c\/p\u003e\n\u003cp\u003eNo. The open-style IP20 housing lacks moisture seals, requiring installation within a climate-controlled enclosure that maintains non-condensing relative humidity conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066455871661,"sku":"1794-ACNR15","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-ACNR15_13.jpg?v=1784508869"},{"product_id":"1794-aent-allen-bradley-flex-i-o-communication-adapter","title":"1794-AENT Allen-Bradley Flex I\/O Communication Adapter","description":"\u003cp\u003eConfigured for high-speed Ethernet\/IP data exchange in distributed control systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1794-AENT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1794-AENT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlex I\/O communication adapter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eDevice Summary Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBase Model: 1794-AENT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Ethernet\/IP Communication Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Interface: 10\/100 Mbps RJ45\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O Capacity: Up to 8 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Requirement: 24 VDC Nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1794-AENT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.4 x 8.8 x 7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Industrial Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.3 W max @ 19.2 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1794-AENT adapter utilizes EtherNet\/IP deterministic networks to facilitate real-time data transfer between field I\/O and controller platforms. It supports high-speed backplane bus communication, ensuring that I\/O density scaling remains predictable across distributed nodes. The hardware supports firmware flash compatibility, allowing for updates that maintain alignment with evolving network protocols and communication logic within the EtherNet\/IP architecture.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit 1794-AENT Communication Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 technical documentation sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Snap the adapter onto a standard 35 mm DIN rail. Ensure the mechanical locking mechanism is fully engaged for vibration resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Terminate the chassis ground connection to a common potential earth rail to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Utilize shielded Category 5 Ethernet cabling. Ensure the RJ45 interface is free of debris and physical stress that could cause connection latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: Connect to a regulated 24 VDC power source. Ensure the voltage remains within the 19.2-31.2 VDC operational window to avoid intermittent resets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 1794-AENT support hot-swapping of I\/O modules?\u003c\/p\u003e\n\u003cp\u003eYes, the adapter supports the hot-swapping of Flex I\/O modules while the adapter is powered, provided the backplane power is managed correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum number of modules supported?\u003c\/p\u003e\n\u003cp\u003eThe 1794-AENT adapter supports a maximum of 8 Flex I\/O modules on a single rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the Ethernet port auto-negotiating?\u003c\/p\u003e\n\u003cp\u003eYes, the RJ45 port supports auto-negotiation for 10\/100 Mbps communication speeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the input voltage drops below 19.2 VDC?\u003c\/p\u003e\n\u003cp\u003eThe module may experience power cycles or loss of communication with the controller if the input voltage falls below the specified threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this adapter be used in a redundant network configuration?\u003c\/p\u003e\n\u003cp\u003eThe 1794-AENT is designed for standard EtherNet\/IP topologies. For redundant networks, specialized hardware or managed switch configurations are required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the module address assigned?\u003c\/p\u003e\n\u003cp\u003eNetwork addressing is typically configured via the Logix 5000 software or via a hardware rotary switch interface depending on the specific revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require an external fuse?\u003c\/p\u003e\n\u003cp\u003eWhile the adapter has internal protection, adhering to local electrical codes regarding auxiliary fusing for the 24 VDC supply is recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the adapter isolated from the backplane?\u003c\/p\u003e\n\u003cp\u003eThe adapter provides basic insulation with a 50 V continuous isolation voltage rating between the field bus and internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066455969965,"sku":"1794-AENT","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-AENT_13.jpg?v=1782454574"},{"product_id":"1794-aentr-allen-bradley-flex-i-o-flex-ethernet-ip-adapter","title":"1794-AENTR Allen-Bradley FLEX I\/O Flex EtherNet\/IP Adapter","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-AENTR\u003c\/strong\u003e serves as the primary \u003cstrong\u003e1794-AENTR\u003c\/strong\u003e Flex EtherNet\/IP Adapter utilized to execute remote I\/O data processing across FLEX I\/O platforms. The device operates as a network interface component that translates physical field signals from adjacent I\/O modules into structured Ethernet packets. Equipped with dual RJ45 interfaces, this hardware executes direct packet routing over industrial networks without introducing software transmission lag into the localized control backplane.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Architecture\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric code designations delineate the precise hardware attributes of this communication node. The \"1794\" string indicates form factor compatibility with standard distributed terminal bases. The \"AENT\" segment specifies an analog\/digital network adapter layout utilizing standard EtherNet\/IP messaging controls. The final \"R\" suffix designates the embedded dual-port hardware architecture, which enables media loop switching routines and line segmentation arrangements without requiring independent layer-2 external switches.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-AENTR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.4x8.5x9.1cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower Dissipation: 6.1 W @ 19.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e20.8 BTU\/hr @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003eTwo (2) RJ45 copper interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Speed\u003c\/td\u003e\n\u003ctd\u003e10 to 100 Mbps auto-negotiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology Layouts\u003c\/td\u003e\n\u003ctd\u003eLinear, Star, and Device Level Ring (DLR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Frame\u003c\/td\u003e\n\u003ctd\u003eSymmetrical standard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Capacity\u003c\/h3\u003e\n\u003cp\u003eThis interface block coordinates localized I\/O density scaling by executing cyclic data packets across the internal bus structure. The hardware establishes Profinet \/ EtherNet\/IP deterministic networks connections, enforcing real-time scheduling constraints over connected terminal bases. Internal logic routines maintain fixed backplane bus communication velocity Licences, isolating localized sub-module updates from external network traffic variations while ensuring strict firmware flash compatibility verification routines during system integration loops.\u003c\/p\u003e\n\u003ch3\u003eLogistics Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-AENTR communication adapter unit\u003c\/li\u003e\n\u003cli\u003e1 x physical hardware mounting guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOn-Site Wiring Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Engagement Method\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHook the upper retention hook of the chassis onto the top profile of the DIN rail, then press firmly inward on the lower enclosure section until the spring-loaded lock snaps onto the rail base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Media Termination Steps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInsert category-rated industrial twisted-pair copper cables into the Link 1 or Link 2 RJ45 receptacles until the plastic tab locks, verifying link light illumination on the corresponding status array.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogic Grounding Framework\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect a dedicated copper ground conductor from the terminal base anchor point to the master enclosure backpanel to eliminate common-mode noise anomalies on the backplane loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Matrix Mechanical Interlock\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlide the initial terminal base horizontally along the lateral positioning channels of the adapter housing to align the internal logic pins before engaging the structural locking screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific limitations govern the hot-swapping capability of this EtherNet\/IP adapter block?\u003c\/p\u003e\n\u003cp\u003eThe module cannot be removed while the system is under power. Disconnecting the adapter drops the remote node link and immediately invalidates the backplane data loop for all attached I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the embedded switch architecture handle packet latency when configured in a linear topology?\u003c\/p\u003e\n\u003cp\u003eThe internal switch hardware utilizes wire-speed pass-through logic, resulting in microsecond-level packet processing delays that preserve deterministic scheduling across multi-node runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure diagnostic signature occurs if a Device Level Ring path breaks during active operation?\u003c\/p\u003e\n\u003cp\u003eThe Network Status indicator flashes to signal a ring fault state, while the adapter automatically switches to a linear routing scheme to prevent data loss or module dropouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 6.1 W power dissipation rating include the current requirement of the attached modules?\u003c\/p\u003e\n\u003cp\u003eNo. The power dissipation metric reflects the internal adapter consumption under peak load. Attached I\/O sub-modules draw their logic current through the separate internal backplane bus regulator limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat procedure fixes an IP address conflict flagged by the network indicators during startup?\u003c\/p\u003e\n\u003cp\u003eThe address must be reassigned using a standard BOOTP\/DHCP utility or static software configuration tools, followed by cycling the 24 VDC input power line to register the change.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the system verify matching firmware revisions across the backplane during module swap-outs?\u003c\/p\u003e\n\u003cp\u003eThe adapter checks the electronic keying parameters of each sub-module against the master controller image file, halting communication if a mismatch in firmware flash compatibility occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this specific unit function as an active network master controller for other remote nodes?\u003c\/p\u003e\n\u003cp\u003eNo. This hardware operates exclusively as a target adapter node, responding to connection requests from a central programmable automation controller rather than generating independent master commands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental protection measures are required to maintain the functionality of the RJ45 interfaces?\u003c\/p\u003e\n\u003cp\u003eThe IP20 open-style enclosure requires mounting within an industrial electrical cabinet that restricts dust accumulation and maintains non-condensing relative humidity levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456035501,"sku":"1794-AENTR","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-AENTR_13.jpg?v=1784508728"},{"product_id":"1794-asb-allen-bradley-flex-i-o-remote-i-o-adapter","title":"1794-ASB Allen-Bradley FLEX I\/O Remote I\/O Adapter","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-ASB\u003c\/strong\u003e serves as the primary \u003cstrong\u003e1794-ASB\u003c\/strong\u003e Remote I\/O Adaptor utilized to execute remote I\/O data processing across FLEX I\/O platforms. The device operates as a hardware gateway that interfaces an external Universal Remote I\/O network link with the local cluster backplane. It manages serial data block transfers, converting master controller commands into discrete logic signals for up to 8 attached I\/O sub-modules without introducing communication cycle latency into the hardware system.\u003c\/p\u003e\n\u003ch3\u003eFunctional Matrix Allocation\u003c\/h3\u003e\n\u003cp\u003eThe product designation sequence maps specific engineering configurations. The \"1794\" code dictates structural and interface alignment with standard distributed terminal blocks. The \"ASB\" suffix identifies the internal architecture as a remote I\/O link processor utilizing a multi-pin logic bus structure. This adapter layout handles synchronous physical word configurations over 3-wire shielded media configurations, routing signals across standard modular backplane slots.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-ASB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e6.7x8.5x6.8cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupported by external 24 VDC voltage supply loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eUniversal Remote I\/O (RIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 8 I\/O module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 open-style architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Mounting\u003c\/td\u003e\n\u003ctd\u003eSymmetrical DIN rail tracking alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Communications\u003c\/h3\u003e\n\u003cp\u003eThis interface component regulates system data integrity by enforcing rigid I\/O density scaling profiles across the internal connections. The device supports local backplane bus communication velocity Licences controls to prevent collision bottlenecks when high-density configurations are requested. Digital signal mapping tracks direct memory image updates, verifying that sub-module arrays operate within specific firmware flash compatibility matrices while matching hardware baud rates across the network trunk line.\u003c\/p\u003e\n\u003ch3\u003eShipment Packing Array\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-ASB remote network adapter block\u003c\/li\u003e\n\u003cli\u003e1 x physical terminal connection document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring and Shielding Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Retention Interlock\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAngle the top slot of the industrial housing over the upper flange of the DIN rail, then drive the lower enclosure edge downward until the locking claw secures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Media Signal Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSecure the blue, clear, and bare shield wires of the remote I\/O cable into the designated 3-pin termination socket, using identical color codes across all active nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Module Serial Coupling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the side interlocking slots of the adapter housing with the initial terminal base plate, pushing horizontally until the internal backplane pins interface completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Conductor Feed Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect the positive and negative leads from an external 24 VDC power supply to the input terminals, checking that torque limits match structural specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific engineering constraints limit the hot-swapping capacity of this communication interface block?\u003c\/p\u003e\n\u003cp\u003eThe module cannot be detached while the backplane power loop is active. Removing the unit breaks the network loop, halting processing for all connected modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the network baud rate parameters calibrated on this specific remote interface hardware?\u003c\/p\u003e\n\u003cp\u003eBaud rate settings are defined mechanically using the DIP switch bank situated on the enclosure surface before the hardware is fastened to the mounting track.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure signature indicates a communication disconnect between the adapter and the master processor?\u003c\/p\u003e\n\u003cp\u003eA network link failure causes the adapter status indicator to flash red, forcing the localized discrete output circuits to shift into their programmed safe states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 0.18 kg weight specification include the field wiring terminal plate or adjacent modules?\u003c\/p\u003e\n\u003cp\u003eNo. The weight represents the standalone network adapter core module, excluding the terminal bases, field wires, or separate network terminator resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat procedure resolves an address configuration conflict between duplicate nodes on the same network run?\u003c\/p\u003e\n\u003cp\u003eThe system loop power must be disconnected, the rotary or DIP switches adjusted to an unassigned node address, and the 24 VDC supply re-applied to reset the block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the hardware structure maintain data synchronization when analog and digital modules are mixed?\u003c\/p\u003e\n\u003cp\u003eThe internal micro-sequencer executes synchronous backplane bus scans, organizing data blocks into a single image frame to manage mixed I\/O configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external terminating resistor required at the network interface connections of this module?\u003c\/p\u003e\n\u003cp\u003eYes. If the adapter serves as the final physical node on the Universal Remote I\/O line, an external resistor must be secured across the signaling terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit function within high-humidity environments without a secondary secondary enclosure box?\u003c\/p\u003e\n\u003cp\u003eNo. The open-style IP20 housing lacks moisture seals, requiring a protective industrial enclosure to prevent condensation from causing electrical degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456101037,"sku":"1794-ASB","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-ASB_13.jpg?v=1784508053"},{"product_id":"1794-ce1-allen-bradley-flex-i-o-extender-cable","title":"1794-CE1 Allen-Bradley FLEX I\/O Extender Cable","description":"\u003cp\u003eConfigured for physical bus length modification in Allen-Bradley automation systems, the \u003cstrong\u003eAllen-Bradley 1794-CE1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-CE1\u003c\/strong\u003e Extender Cable, provides direct physical\/electrical execution. This hardware element extends the connections between consecutive terminal bases, allowing modular configurations to span separate enclosure areas or drop across multiple rows. It establishes a multi-conductor path for power and logic routing directly between adjacent bus segments without adding propagation latency.\u003c\/p\u003e\n\u003ch3\u003eCatalog Designation Details\u003c\/h3\u003e\n\u003cp\u003eThe standard part number specifies a predetermined hardware setup within the product ecosystem. The \"1794\" designation references the specific modular architecture compatibility, while the \"CE1\" suffix identifies this assembly as a predefined length connection line. Variations within this line dictate specific lengths, where this unit remains fixed at a metric configuration without additional internal structural modifications or modular alterations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-CE1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 cm x 7.6 cm x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (zero active power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (open-style protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eProprietary backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Bus Performance \u0026amp; Density Constraints\u003c\/h3\u003e\n\u003cp\u003eThis component functions natively within the controller framework to maintain backplane bus communication velocity Licences protocols. The structural design preserves signal transition times across the extended interface, preventing data collisions or dropouts within high-density I\/O distributions. It interfaces directly with localized EtherNet\/IP and ControlNet adapter arrangements to sustain high-speed packet routing, remaining neutral to system firmware flash compatibility metrics while eliminating voltage drops across the extended logic lines.\u003c\/p\u003e\n\u003ch3\u003eShipment Provisions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-CE1 extender cable assembly\u003c\/li\u003e\n\u003cli\u003e1 x installation instruction document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Placement Actions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Clearance Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the routing path provides a bending radius that avoids tight kinks, preventing structural degradation of the internal conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Engagement Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the male and female connector ends parallel to the terminal base socket before applying force, avoiding pin deflection or uneven seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Entry Seals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify the installation path conforms to the IP20 standard, keeping the assembly within dry, non-condensing environments away from conductive contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Shield Stability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the connection line away from high-voltage conduit runs and motor starter wiring to minimize induced electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Field Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan this specific model be coupled in a series arrangement with a duplicate unit to lengthen the run?\u003c\/p\u003e\n\u003cp\u003eNo. Linking multiple extension units in series alters signal propagation timing and introduces impedance variations that degrade data integrity across the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the limitations regarding hot-swapping or replacing this part while power is active?\u003c\/p\u003e\n\u003cp\u003eThe system must be completely powered down before separating the connection. Removing the line during active operation breaks the backplane loop, causing an immediate rack fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the addition of this component affect the total backplane current capacity allocated to modules?\u003c\/p\u003e\n\u003cp\u003eThis unit acts as a passive conductor path, meaning it introduces negligible resistive loss and does not diminish the current capacity provided by the adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this internal wire harness certified for installation directly in environments exposed to moisture?\u003c\/p\u003e\n\u003cp\u003eNo. This product features an open-style IP20 housing configuration, which requires installation within a protective enclosure that controls dust and prevents moisture access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the structural routing profile require specific shielding connections to prevent data distortion?\u003c\/p\u003e\n\u003cp\u003eThe assembly includes internal shielding paths linked through the terminal base pins, eliminating the need for external ground braid bonding by the installer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat indicator confirms the secure mechanical interlocking of the end ports during installation?\u003c\/p\u003e\n\u003cp\u003eSecure engagement relies on a physical slide lock mechanism that clicks into position, ensuring constant connection stability during vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWill using this hardware component require updates or parameter modifications inside the programming software?\u003c\/p\u003e\n\u003cp\u003eNo software parameter adjustments are needed. The module configuration remains unchanged, as the hardware serves exclusively as a physical extension of the existing bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure signature indicates that an internal conductor inside the line has fractured?\u003c\/p\u003e\n\u003cp\u003eConductor fractures manifest as intermittent module communication drops or complete adapter faults, logged as rack communication errors within the master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456133805,"sku":"1794-CE1","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-CE1_15.jpg?v=1784443746"},{"product_id":"1794-fla-allen-bradley-flexlogix-extended-local-io-adapter-controllogix","title":"1794-FLA Allen-Bradley FlexLogix Extended-local IO Adapter ControlLogix","description":"\u003cp\u003eConfigured for local I\/O expansion routing in ControlLogix and FlexLogix systems, the \u003cstrong\u003eAllen-Bradley 1794-FLA\u003c\/strong\u003e (\u003cstrong\u003e1794-FLA\u003c\/strong\u003e FlexLogix Extended-local IO Adapter) provides direct physical\/electrical execution. This hardware component serves as a local bus extension interface, transferring high-speed logic signals directly from the primary controller backplane to downstream FLEX I\/O module banks. It functions as a transparent bridge, maintaining synchronous signal propagation across extended physical distances without inserting timing degradation into the discrete or analog control loops.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Identifier Matrix\u003c\/h3\u003e\n\u003cp\u003eThe configuration sequence dictates the exact physical and electrical architecture of the device interface. The prefix code \"1794\" specifies absolute physical alignment and bus compatibility with standard industrial terminal bases. The suffix code \"FLA\" defines this specific unit as a FlexLogix\/ControlLogix extended-local subsystem adapter block. This layout is designed to anchor directly onto local extension cables, passing upstream controller backplane communications through dedicated multi-pin logic channels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters and Hardware Boundaries\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-FLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1x5.5x7.6cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput Current: 0.39 A max. @ 19.2V DC; 0.25 A max. @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2-31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexbus Output Current\u003c\/td\u003e\n\u003ctd\u003e653 mA max. @ 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC continuous between logic and external power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connector Torque\u003c\/td\u003e\n\u003ctd\u003e0.6-0.8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e7.5 W max @ 19.2V; 6.0 W max. @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e25.6 BTU\/hr. @ 19.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Execution and Density Scaling\u003c\/h3\u003e\n\u003cp\u003eOperating inside high-density distributed architectures, this interface block strictly maintains backplane bus communication velocity Licences profiles. It interfaces directly with logic control platforms via high-speed connections, providing the current scaling required to drive adjacent internal logic circuits without altering network packet timing metrics. The hardware ensures complete firmware flash compatibility matching across the connected sub-rack, preventing data frame drops during localized high-velocity I\/O scans.\u003c\/p\u003e\n\u003ch3\u003eShipping Kit Composition\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-FLA hardware adapter block\u003c\/li\u003e\n\u003cli\u003e1 x detailed wire termination guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Integration Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Component Attachment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOrient the adapter block parallel to the mounting surface, snapping the integrated lower retention latch onto the standard DIN rail profile until locked securely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Connection Torque Enforcement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInsert the external 24 VDC power conductors into the designated terminal ports, utilizing a calibrated driver to tighten the screws to exactly 0.6-0.8 Nm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended-Local Bus Cable Seating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the multi-pin logic ribbon cable parallel with the entry socket on the adapter housing, pressing firmly until the lateral locking ears latch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEquipotential Ground Path Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEstablish a direct low-impedance copper ground link from the din rail tracking to the central enclosure ground plate to mitigate common-mode electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific limitations govern the hot-swapping capacity of this extended-local adapter component?\u003c\/p\u003e\n\u003cp\u003eThe module must never be unseated while the primary system power loop is active. Removing the unit breaks the active local bus path, inducing an immediate controller fault state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 653 mA maximum Flexbus output parameter affect system I\/O density scaling options?\u003c\/p\u003e\n\u003cp\u003eThe cumulative 5.1 VDC internal logic current consumption of all attached I\/O modules must remain under 653 mA, or the unit will initiate an overcurrent shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure diagnostic signature is reported to the controller if the extension cable disconnects?\u003c\/p\u003e\n\u003cp\u003eA cable disconnect halts the local bus scan, causing the processor to log an I\/O adapter loss fault and instantly moving all connected output circuits to safe states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 30 VDC isolation rating allow the device to connect directly to line-voltage switching circuits?\u003c\/p\u003e\n\u003cp\u003eNo. The 30 VDC isolation is designed strictly for low-voltage signal separation. High-voltage field circuits must be isolated using external interposing relays or barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat procedure resolves an unexpected internal logic lockup flag on this adapter node?\u003c\/p\u003e\n\u003cp\u003eThe system loop power must be completely disconnected, the external 24 VDC input lines verified to be within 19.2-31.2 VDC limits, and power cycled to clear the logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility verified between this module and the primary automation controller?\u003c\/p\u003e\n\u003cp\u003eThe central processor evaluates the hardware revision keying parameters during the power-up sequence, checking that the module matches the software hardware profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the external power terminals accept solid copper conductors without using wire ferrules?\u003c\/p\u003e\n\u003cp\u003eYes. The compression terminals support solid wire, provided the installation torque is maintained within the required 0.6-0.8 Nm range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental protection measures are necessary to ensure the open-style enclosure operates reliably?\u003c\/p\u003e\n\u003cp\u003eThe IP20 rated frame requires mounting within an unventilated dust-free control cabinet that prevents moisture condensation and blocks conductive debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456199341,"sku":"1794-FLA","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-FLA_13.jpg?v=1784443568"},{"product_id":"1794-ia8-allen-bradley-flex-i-o-digital-input-module","title":"1794-IA8 Allen-Bradley FLEX I\/O Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-IA8\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-IA8\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete AC signal sensing within FLEX I\/O platforms. It functions as a centralized input interface that converts alternating current field signals into system-level logic states, providing step-down conversion and optical isolation for 8 independent instrument channels across the local terminal base backplane loop without introducing cycle latency to the master controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation Profile\u003c\/h3\u003e\n\u003cp\u003eThe model structure identifies the underlying electronic layout and subsystem classification. The \"1794\" designation forces absolute physical and electrical matching with industrial terminal bases. The \"IA\" identifier defines an alternating current discrete voltage configuration, while the suffix \"8\" indicates the total internal sensing channel density. The module matches standard execution criteria for backward compatibility across multiple system firmware revisions.\u003c\/p\u003e\n\u003ch3\u003eElectromechanical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IA8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.2x7.6x10.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupported by Flexbus current loop and 120 VAC input circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Inputs\u003c\/td\u003e\n\u003ctd\u003e8 points, non-isolated group configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eOpen style IP20 rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubstructure Mount\u003c\/td\u003e\n\u003ctd\u003eDIN rail tracking alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Integration Metrics\u003c\/h3\u003e\n\u003cp\u003eThis physical block regulates signal delivery through standard interfaces while protecting data integrity across high-density I\/O configurations. The circuit board operates within fixed backplane bus communication velocity Licences profiles, processing discrete state changes without generating bandwidth delays. The internal controller logic maintains strict hardware execution, confirming firmware flash compatibility across standard EtherNet\/IP or ControlNet industrial configurations.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-IA8 discrete input hardware block\u003c\/li\u003e\n\u003cli\u003e1 x mechanical mounting installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Field Termination Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Engagement Lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAngle the top indentation of the plastic housing over the upper lip of the DIN rail, then drive the lower enclosure edge downward until the spring-loaded claw clicks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Insertion Path\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the structural alignment keys of the module with the mating terminal base plate slots, sliding vertically until the pin connectors are completely mated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC Input Conductor Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStrip the 120 VAC field signal wires and fasten them into the corresponding terminal base channels, confirming torque settings match base panel parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Earth Ground Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEstablish a heavy-duty low-impedance copper line from the mounting track to the main electrical panel earth point to eliminate stray common-mode interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Queries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat constraints apply to hot-swapping this specific input module under live system conditions?\u003c\/p\u003e\n\u003cp\u003eThe module can be removed under power if the field terminal base configuration supports RIUP, but the 120 VAC external input loops must be isolated to prevent hazardous arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does backplane current draw shift when all 8 input circuits are simultaneously driven to an active high state?\u003c\/p\u003e\n\u003cp\u003eThe logic draw remains within specified limits, but thermal dissipation rises, requiring proper clearance boundaries to prevent temperature accumulation on the terminal base block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signature indicates an internal circuit isolation failure or a blown component trace?\u003c\/p\u003e\n\u003cp\u003eAn internal component failure turns off the specific point status LED, while the master controller reports a channel communication fault code for the adapter rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require an external neutral return line for every discrete alternating current input point?\u003c\/p\u003e\n\u003cp\u003eNo. The 8 input channels share a common internal neutral reference line distributed across the corresponding terminal base connections, reducing external field wiring steps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat procedure fixes an optical coupler latency lag during high-frequency signal cycle updates?\u003c\/p\u003e\n\u003cp\u003eThe 1794-IA8 is designed for 50\/60 Hz line sensing. If input frequencies exceed rated specs, the module must be replaced with a high-speed DC module paired with interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility verified for the module hardware assembly?\u003c\/p\u003e\n\u003cp\u003eThe unit uses fixed hardware logic for AC-to-DC conversion, meaning compatibility is handled by configuring the electronic keying parameters within the main controller I\/O configuration tool.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan 24 VDC control signals be fed into the module terminal points for testing purposes?\u003c\/p\u003e\n\u003cp\u003eNo. The input circuitry requires 120 VAC to cross the internal threshold. Low-voltage DC signals will fail to activate the opto-isolator circuits, keeping the point low.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat enclosure step is required if the system operates near water or conductive dust paths?\u003c\/p\u003e\n\u003cp\u003eThe open IP20 frame lacks environmental seals. The module must be housed in a secondary NEMA or IP54 industrial cabinet to block liquid ingress and particulate settling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456395949,"sku":"1794-IA8","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-IA8_13.jpg?v=1784443397"},{"product_id":"1794-ib16d-allen-bradley-flex-i-o-digital-input-module","title":"1794-IB16D Allen-Bradley FLEX I\/O Digital Input Module","description":"\u003cp\u003eConfigured for discrete DC signal monitoring and open\/short circuit fault detection in automation systems, the \u003cstrong\u003eAllen-Bradley 1794-IB16D\u003c\/strong\u003e (\u003cstrong\u003e1794-IB16D\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution. This hardware unit operates as a high-density 24 VDC industrial sensing interface, capturing 16 binary field states via integrated sensor-side diagnostic electronics and transferring processed logical status arrays to the primary system controller over the localized terminal base backplane connection.\u003c\/p\u003e\n\u003ch3\u003eHardware Nomenclature Matrix\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric characters define the internal hardware configuration and electronic operating rules. The prefix \"1794\" specifies absolute mounting and form factor scaling for the modular FLEX I\/O platform. The character string \"IB\" classifies the module as a sinking direct current circuit design, the numeric value \"16\" sets the active channel density, and the terminal suffix \"D\" denotes the presence of wire-fault and sensor-side diagnostics.\u003c\/p\u003e\n\u003ch3\u003eElectromechanical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IB16D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.5 cm x 4.4 cm x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupported by Flexbus current loop and 24 VDC field input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 points with sensor-side diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eOpen style IP20 architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubstructure Mount\u003c\/td\u003e\n\u003ctd\u003eDIN rail tracking alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Performance\u003c\/h3\u003e\n\u003cp\u003eThis physical block regulates signal transmission through standard interfaces while protecting data integrity across high-density I\/O configurations. The circuit board operates within fixed backplane bus communication velocity Licences profiles, processing discrete state changes without generating bandwidth delays. The internal controller logic maintains strict hardware execution, confirming firmware flash compatibility across standard EtherNet\/IP or ControlNet industrial configurations.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-IB16D diagnostic input module\u003c\/li\u003e\n\u003cli\u003e1 x mechanical installation data sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring and Shielding Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Engagement Lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHook the top slot of the module housing over the upper flange of the DIN rail, then drive the lower edge downward until the spring-loaded clip locks onto the track.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Insertion Path\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the structural registration keys on the underside of the module with the mating terminal base plate slots, sliding down until the pins couple with the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Power and Signal Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStrip the 24 VDC field wires and terminate them into the corresponding terminal base channels, verifying wire positioning matches the diagnostic sinking circuit layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Earth Ground Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEstablish a heavy-duty low-impedance copper link from the DIN rail track to the main cabinet earth point to minimize common-mode high-frequency interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Queries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat limitations govern the live replacement or hot-swapping of this diagnostic input module?\u003c\/p\u003e\n\u003cp\u003eThe module supports Removal and Insertion Under Power (RIUP) when installed on a compatible terminal base, but field power lines must be isolated to prevent contact arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal diagnostic system differentiate between a real input low state and a broken wire fault?\u003c\/p\u003e\n\u003cp\u003eThe module monitors sensor current draw; an open circuit drops the current loop below the defined threshold, forcing a fault flag distinct from a regular low logic state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat failure diagnostic signature is routed to the master processor if a field sensor loop short-circuits?\u003c\/p\u003e\n\u003cp\u003eA sensor short-circuit triggers an overcurrent flag, causing the localized channel status LED to indicate a fault and passing an I\/O fault word to the master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require an external return path for each of the 16 sinking direct current points?\u003c\/p\u003e\n\u003cp\u003eNo. The 16 input channels reference a common internal direct current return line distributed across the terminal base structure, minimizing external field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat procedure clears a latched electronic sensor short-circuit fault after correcting the field wiring?\u003c\/p\u003e\n\u003cp\u003eThe field fault must be physically resolved, followed by an electronic fault reset command sent from the controller or a brief power-cycling of the 24 VDC sensor supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does high-density I\/O configurations affect the thermal dissipation profiles of the IP20 housing?\u003c\/p\u003e\n\u003cp\u003eSimultaneous activation of all 16 channels increases internal heat generation, requiring strict adherence to the specified 55 deg C environment threshold and clearance limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module process high-speed counter pulse inputs from industrial rotary encoders?\u003c\/p\u003e\n\u003cp\u003eNo. The input filtering circuitry introduces a hardware delay meant for debounce suppression, limiting the device to low-frequency industrial discrete state tracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat enclosure step is required if the system operates in environments with corrosive atmospheric content?\u003c\/p\u003e\n\u003cp\u003eThe open IP20 structural design has no chemical sealing; it must be installed inside a sealed secondary NEMA or IP54 cabinet with appropriate climate control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456461485,"sku":"1794-IB16D","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-IB16D3.jpg?v=1784443003"},{"product_id":"1794-ib16xob16p-allen-bradley-flex-i-o-digital-combination-module","title":"1794-IB16XOB16P Allen-Bradley FLEX I\/O Digital Combination Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-IB16XOB16P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-IB16XOB16P\u003c\/strong\u003e Flex 32 Point Digital Combination Module, operates as a dedicated hardware component for concurrent discrete input sensing and output actuation within FLEX I\/O platforms. The assembly functions as a high-density, mixed-mode module interfacing directly with 24 VDC field equipment. It routes 16 sinking binary inputs and 16 electronically protected sourcing outputs through a standardized terminal base interface to the remote or local rack controller backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation Profile\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric code designates the physical density and internal electronics configuration of the combination board. The identifier \"1794\" enforces mechanical and signal compliance with the standard industrial FLEX I\/O chassis matrix. The segment \"IB16\" defines 16 independent channels configured for direct current sinking operations, while the following string \"XOB16P\" specifies 16 sourcing direct current output channels equipped with integrated electronic short-circuit protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IB16XOB16P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.2x4.5x5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by external 24 VDC source and internal Flexbus current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 points (16 sinking inputs \/ 16 sourcing outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Scheme\u003c\/td\u003e\n\u003ctd\u003eElectronic short-circuit overload protection on sourcing outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen style IP20 architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Orientation\u003c\/td\u003e\n\u003ctd\u003eHorizontal or vertical DIN rail mounting alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDensity Scaling and Firmware Verification\u003c\/h3\u003e\n\u003cp\u003eThe electronic architecture regulates synchronous signal processing across combined input and output matrices without degrading network data updates. The internal microcode functions within defined backplane bus communication velocity Licences profiles, preventing packet collision across the rack infrastructure. This hardware configuration permits multi-channel I\/O density scaling inside localized control cells while matching factory electronic keying rules for firmware flash compatibility.\u003c\/p\u003e\n\u003ch3\u003eShipping Kit Composition\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-IB16XOB16P combination I\/O module\u003c\/li\u003e\n\u003cli\u003e1 x factory electrical installation reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSubstructure Mounting \u0026amp; Shielding Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Engagement Lock\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHook the upper retention slot of the IP20 housing over the top flange of the DIN rail, then snap the lower edge downward until the spring-loaded lock fastens onto the steel profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Insertion Path\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the structural alignment keyways on the bottom of the module with the registration pin of the terminal base unit, pushing vertically until the multi-pin connector fully mates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Power and Signal Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStrip the 24 VDC field wires and connect the sinking input leads and sourcing output leads to the designated terminal base channels, isolating the positive rail for the outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEquipotential Ground Path Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEstablish a direct low-impedance copper ground connection from the DIN rail track to the central cabinet enclosure grounding plate to eliminate common-mode high-frequency noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific boundaries govern the hot-swapping or RIUP capabilities of this combination module?\u003c\/p\u003e\n\u003cp\u003eRemoval and Insertion Under Power is permitted when using a compatible terminal base, but field-side 24 VDC power loops must be physically isolated first to prevent electrical arcing across contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the integrated electronic protection react during a downstream short-circuit on an output point?\u003c\/p\u003e\n\u003cp\u003eThe electronic short-circuit protection instantly trips the affected channel to a safe, non-conducting state, lighting the localized fault indicator and setting an internal data status flag.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this mixed-mode configuration allow the grouping of sinking inputs and sourcing outputs on a single common line?\u003c\/p\u003e\n\u003cp\u003eNo. Sinking inputs require the field device to switch the positive leg to the module, whereas sourcing outputs actively drive current out from the positive rail to the field load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signature is recorded by the primary controller if the internal Flexbus logic current exceeds current limits?\u003c\/p\u003e\n\u003cp\u003eThe system interface drops the module connection, logs a slot communication timeout fault inside the processor logic matrix, and forces all 16 sourcing outputs to an unpowered state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat procedure clears a latched electronic protection fault state after fixing a shorted field device?\u003c\/p\u003e\n\u003cp\u003eThe external field short-circuit must be fully eliminated, and then the channel must be reset either through a programmatic controller command toggle or by cycling the module field power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does maximum simultaneous channel activation impact the thermal dissipation limits of the IP20 chassis?\u003c\/p\u003e\n\u003cp\u003eRunning all 32 points at continuous maximum load increases thermal output, requiring strict enforcement of the 55 deg C temperature limit and minimum physical layout clearances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be used with AC voltage field instruments if interposing terminals are absent?\u003c\/p\u003e\n\u003cp\u003eNo. The module internal optocouplers and transistors operate exclusively on direct current 24 VDC loops; feeding alternating current into the module will cause catastrophic circuit failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility handled between different assembly revisions of this module?\u003c\/p\u003e\n\u003cp\u003eThe device features hardware-defined logic routing, meaning software compatibility is maintained by adjusting the electronic keying parameters within the main automation software configuration tree.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456527021,"sku":"1794-IB16XOB16P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-IB16XOB16P_14.jpg?v=1784442689"},{"product_id":"1794-ib32-allen-bradley-flex-i-o-digital-input-module","title":"1794-IB32 Allen-Bradley FLEX I\/O Digital Input Module","description":"\u003cp\u003eConfigured for high-density discrete DC signal conversion in automation systems, the \u003cstrong\u003eAllen-Bradley 1794-IB32\u003c\/strong\u003e (\u003cstrong\u003e1794-IB32\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution. This hardware assembly acts as a centralized interface component that transitions 32 individual direct current sinking binary field inputs into logic states. It channels the processed voltage transitions across the integrated backplane bus interface to the primary network adapter without inserting cyclic computational delays.\u003c\/p\u003e\n\u003ch3\u003eComponent Designator Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric characters define the hardware attributes of this high-density circuit board. The \"1794\" code establishes absolute form factor compliance with standard industrial FLEX I\/O terminal block structures. The string \"IB\" designates a direct current sinking input configuration requiring field devices to supply positive voltage. The numeric suffix \"32\" dictates the absolute channel density packed into the open-style enclosure architecture.\u003c\/p\u003e\n\u003ch3\u003eElectromechanical Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-IB32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.4x5x5.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupported by external 24 VDC distribution loop and internal bus current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Voltage, min\u003c\/td\u003e\n\u003ctd\u003e10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Voltage, max\u003c\/td\u003e\n\u003ctd\u003e31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF State Voltage, max\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC (24 VDC nominal loop reference)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Input Channels\u003c\/td\u003e\n\u003ctd\u003e32 point sinking matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Array\u003c\/td\u003e\n\u003ctd\u003e32 yellow status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 open style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLocal Bus Determinism\u003c\/h3\u003e\n\u003cp\u003eThis hardware component manages localized I\/O density scaling by executing cyclic data acquisition routines across the terminal base path. The module runs in strict alignment with backplane bus communication velocity Licences protocols to maintain steady logic updates over the rack assembly. The high-density processing circuits match precise manufacturing parameters to preserve firmware flash compatibility across linked EtherNet\/IP adapter units.\u003c\/p\u003e\n\u003ch3\u003eProcurement Package Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-IB32 high-density digital input module\u003c\/li\u003e\n\u003cli\u003e1 x mechanical installation reference data sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mounting Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Attachment Sequence\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHook the upper retention slots of the IP20 plastic frame over the top lip of the DIN rail track, then press downward and inward until the lower spring latch locks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Insertion Path\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlign the alignment keys on the bottom face of the module with the registration slots on the terminal base unit, pushing straight down until the multi-pin connector fully seats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSinking Circuit Conductor Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStrip the 24 VDC field input wires and terminate them into the specified high-density terminal block paths, ensuring the external positive loop lines feed the sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEquipotential Chassis Ground Path\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify a clean low-impedance copper strap bonds the DIN rail carrier to the master electrical enclosure grounding bus to suppress induced high-frequency electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat boundaries limit the live insertion or hot-swapping of this high-density input unit?\u003c\/p\u003e\n\u003cp\u003eThe module permits Removal and Insertion Under Power (RIUP) if using a compatible terminal base, but the external 24 VDC field power loop must be isolated to prevent arcing across backplane pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module handle signal debounce processing for the 32 discrete direct current points?\u003c\/p\u003e\n\u003cp\u003eThe hardware enforces an internal hardware filter delay on each input channel to minimize contact bounce transitions before passing the stable logic state to the adapter bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat state changes occur on the 32 yellow indicators when an input drop below 10 VDC happens?\u003c\/p\u003e\n\u003cp\u003eThe individual yellow status indicator turns off immediately as the input voltage drops below the minimum threshold required to maintain the active high logic state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this sinking architecture allow direct wiring of sourcing (PNP) proximity sensor outputs?\u003c\/p\u003e\n\u003cp\u003eYes. Sinking inputs require the input channel to draw current from a sourcing source, making the module directly compatible with standard 24 VDC PNP type industrial field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of electrical failure signature occurs if the internal logic current loop is overloaded?\u003c\/p\u003e\n\u003cp\u003eAn internal bus overload causes the communication link to fail, prompting the upstream network adapter to report a module communication timeout error and turning off all status LEDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does concurrent activation of all 32 points impact thermal dissipation in an IP20 open enclosure?\u003c\/p\u003e\n\u003cp\u003eSimultaneous activation at 31.2 VDC raises internal temperatures, requiring strict adherence to the 55 deg C operating limit and proper cabinet clearance boundaries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit be mounted without a terminal base block directly to a standard symmetrical tracking rail?\u003c\/p\u003e\n\u003cp\u003eNo. The module lacks field wire terminals and direct rail claws on its main body, requiring attachment to a compatible 1794 terminal base to secure power and signal paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat action solves an electronic keying configuration mismatch fault flagged by the programming tool?\u003c\/p\u003e\n\u003cp\u003eThe installer must update the I\/O properties inside the controller software project tree to match the physical module model, revision level, and firmware flash compatibility metrics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066456559789,"sku":"1794-IB32","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-IB32_13.jpg?v=1784214973"}],"url":"https:\/\/www.maxwellplc.com\/ru\/collections\/allen-bradley-distributed-i-o-flex-point.oembed?page=6","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}