{"product_id":"ypk112a-3asd573001a13-abb-communication-module-industrial-control-systems","title":"YPK112A 3ASD573001A13 ABB Communication Module Industrial Control Systems","description":"\u003cp\u003eThe \u003cstrong\u003eABB YPK112A 3ASD573001A13\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eYPK112A\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for executing personal computer communication and PAL-circuit signal processing within industrial control systems.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown \u0026amp; Configuration Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Level\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eIdentifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003ctd\u003eManufacturer entity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eIndustrial Control Systems\u003c\/td\u003e\n\u003ctd\u003eModular automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eYPK112A\u003c\/td\u003e\n\u003ctd\u003eCommunication Module designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Part Number\u003c\/td\u003e\n\u003ctd\u003e3ASD573001A13\u003c\/td\u003e\n\u003ctd\u003eFactory catalog reference ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYPK112A 3ASD573001A13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e18.5 cm x 8.4 cm x 2.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003ePC Communication Board \/ PAL-Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eInternal slot or rack chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Network Communication Parameters\u003c\/h3\u003e\n\u003cp\u003eThe hardware utilizes backplane bus communication velocity licences to maintain deterministic packet transfers across node racks. I\/O density scaling capabilities allow operators to expand node connectivity without violating bus update intervals. Firmware flash compatibility ensures that low-level communication protocol stacks remain synchronized across distributed architectures during active process operations.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB YPK112A Communication Module (Part Number: 3ASD573001A13)\u003c\/li\u003e\n\u003cli\u003e1 x ESD Protective Packaging Enclosure\u003c\/li\u003e\n\u003cli\u003e1 x Technical Compliance Documentation Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation \u0026amp; Grounding Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure system power is completely isolated before inserting or removing the printed circuit board from its designated slot.\u003c\/li\u003e\n\u003cli\u003eAlign the board edge connector precisely with the backplane guide rails to prevent bending pins during insertion.\u003c\/li\u003e\n\u003cli\u003eSecure any board-level retention screws to maintain mechanical stability against continuous industrial vibration.\u003c\/li\u003e\n\u003cli\u003eVerify that grounding clips make firm contact with the chassis to suppress electromagnetic interference on communication lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the primary operational function of this module within the control network?\u003c\/li\u003e\n\u003cli\u003eA: It serves as a PC communication board utilizing PAL-circuit architecture to handle internal data exchanges.\u003c\/li\u003e\n\u003cli\u003eQ: Does this communication board support live insertion and removal (hot-swapping)?\u003c\/li\u003e\n\u003cli\u003eA: Hot-swap capability depends entirely on the specific rack architecture and system power configuration.\u003c\/li\u003e\n\u003cli\u003eQ: What is the specified operating temperature range for the hardware?\u003c\/li\u003e\n\u003cli\u003eA: The module functions reliably within an ambient temperature range of 0 deg C to +55 deg C.\u003c\/li\u003e\n\u003cli\u003eQ: How does firmware management affect module operation?\u003c\/li\u003e\n\u003cli\u003eA: Firmware revisions must match the host controller requirements to ensure correct protocol stack execution.\u003c\/li\u003e\n\u003cli\u003eQ: What precautions are necessary during handling to prevent component damage?\u003c\/li\u003e\n\u003cli\u003eA: Operators must utilize standard electrostatic discharge (ESD) wrist straps and anti-static mats during maintenance.\u003c\/li\u003e\n\u003cli\u003eQ: Why must retention screws be fastened securely on the board?\u003c\/li\u003e\n\u003cli\u003eA: Fastening screws maintain low-impedance grounding and prevent the board from dislodging under high vibration.\u003c\/li\u003e\n\u003cli\u003eQ: Can this module be installed in non-ABB control racks?\u003c\/li\u003e\n\u003cli\u003eA: No, it is specifically engineered for compatibility with proprietary ABB industrial control hardware slots.\u003c\/li\u003e\n\u003cli\u003eQ: What standard maintenance procedures apply to this unit?\u003c\/li\u003e\n\u003cli\u003eA: Periodically inspect the board surface for dust accumulation and verify that edge connectors remain clean and oxidation-free.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021159289005,"sku":"3ASD573001A13","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3ASD573001A13_24_9c235be8-267b-429b-9d20-6caf19287681.jpg?v=1784534295","url":"https:\/\/www.maxwellplc.com\/products\/ypk112a-3asd573001a13-abb-communication-module-industrial-control-systems","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}