{"product_id":"yokogawa-ycb301-c200-esb-bus-cable-2m-36-36-pins-for-centum-vp-cs-3000","title":"Yokogawa YCB301-C200 ESB Bus Cable 2m (36-36 pins) for CENTUM VP\/CS 3000","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"citation-13\"\u003eThe Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eYCB301-C200\u003c\/strong\u003e\u003cspan class=\"citation-13 citation-end-13\"\u003e\u003cspan\u003e \u003c\/span\u003eserves as a vital data highway within the CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis 2-meter ESB (Enhanced Service Bus) cable facilitates the high-speed, deterministic connection between Field Control Units (FCUs) and node units such as the ANB10 or ANB11. Engineered for mission-critical automation, it enables the millisecond-level data synchronization required to manage complex control loops and safety instrumented functions in large-scale industrial plants.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-12\"\u003eIn environments prone to electrical interference, such as power generation or petrochemical facilities, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eYCB301-C200\u003c\/strong\u003e\u003cspan class=\"citation-12 citation-end-12\"\u003e\u003cspan\u003e \u003c\/span\u003eprovides superior signal protection.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-11 citation-end-11\"\u003eIts advanced foil shielding effectively neutralizes electromagnetic interference (EMI), ensuring that critical process variables and control commands are transmitted without corruption.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-10 citation-end-10\"\u003eThe industrial-grade 36-pin connectors are built to withstand the physical rigors of high-vibration cabinets, maintaining a consistent, low-latency link across the entire system backplane.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel utilizes a structured suffix system to specify its physical application within the DCS network architecture.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-9\"\u003e\u003c\/span\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e\u003cspan class=\"citation-9 citation-end-9\"\u003e: Designates the primary ESB Bus Cable series, featuring proprietary high-density 36-pin connectors designed for Yokogawa FIO (Field Internal Operator) systems.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-8\"\u003e\u003c\/span\u003e\u003cstrong\u003e-C200\u003c\/strong\u003e\u003cspan class=\"citation-8 citation-end-8\"\u003e: Defines the exact physical length of the cable.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-7 citation-end-7\"\u003eThe \"200\" indicates a 2.0-meter span (approximately 6.56 feet), offering sufficient length to bridge multiple node units or connect across adjacent cabinet sections.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eYCB301-C200\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36-pin to 36-pin Industrial Grade\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Meters (6.56 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus (Enhanced Service Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP, CS 3000, ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3A per pin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFoil shielded for EMI\/RFI noise protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBending Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 45 mm (Avoid tight loops)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg (Approx. 2.2 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (Packing)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 cm × 16 cm × 12 cm (6.4\" × 6.4\" × 4.8\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eCorrect deployment of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures maximum system uptime. Engineers should implement the following best practices:\u003c\/p\u003e\n\u003ch3\u003eConnector Integrity\u003c\/h3\u003e\n\u003cp\u003eFirmly seat the 36-pin connectors into the designated ESB ports on the FCU or node module. Secure the integrated thumb-screws by hand to ensure a stable electrical connection. Over-tightening with tools is unnecessary and can damage the module's backplane interface.\u003c\/p\u003e\n\u003ch3\u003eRouting and EMI Prevention\u003c\/h3\u003e\n\u003cp\u003eUse the 2-meter length to route the cable through dedicated communication cable trays. Avoid placing the bus cable directly adjacent to high-current power cables or variable frequency drives (VFDs) to prevent inductive noise coupling, despite the cable's internal shielding.\u003c\/p\u003e\n\u003ch3\u003eBend Radius Compliance\u003c\/h3\u003e\n\u003cp\u003eNever subject the cable to sharp 90-degree kinks. Maintain a minimum bending radius of 45 mm at all times. Stressing the internal conductors or shielding layer through excessive bending can lead to intermittent CRC (Cyclic Redundancy Check) errors or bus failure alarms in the system diagnostic logs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed to eliminate the \"Bus Fault\" issues common with non-original accessories. Its gold-plated contact points prevent micro-oxidation, which is the primary cause of intermittent signal loss in humid or corrosive industrial environments. Furthermore, its rugged outer jacket is resistant to chemical splashes and mechanical abrasion, ensuring it survives the lifespan of the DCS hardware. By choosing this genuine Yokogawa cable, you maintain the full E-E-A-T standards of your facility's control architecture and ensure seamless integration with the system's real-time diagnostic and self-calibration tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDelivery and Logistics\u003c\/h2\u003e\n\u003cp\u003eWe maintain a ready-to-ship stock of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecables to support urgent maintenance and project expansion.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGlobal express shipping by DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped in a new, original sealed pack with full protection for the connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I use the YCB301-C200 for V net communication?\u003c\/p\u003e\n\u003cp\u003eA1: No. This cable is specifically for the ESB Bus. V net communication requires different coaxial (YCB141) or twisted pair (YCB111) cables depending on the network type.\u003c\/p\u003e\n\u003cp\u003eQ2: Is this cable compatible with redundant node units?\u003c\/p\u003e\n\u003cp\u003eA2: Yes. In redundant setups, you must use two separate cables—one for the primary bus and one for the secondary bus—to ensure full system availability.\u003c\/p\u003e\n\u003cp\u003eQ3: What should I check if I get an \"ESB Bus ERR\" lamp on the node unit?\u003c\/p\u003e\n\u003cp\u003eA3: First, verify that both ends of the YCB301-C200 are securely fastened with the thumb-screws. If the error persists, inspect the cable for physical damage or sharp bends that exceed the 45 mm limit.\u003c\/p\u003e\n\u003cp\u003eQ4: Does the length of 2 meters affect data speed?\u003c\/p\u003e\n\u003cp\u003eA4: No. The ESB architecture is designed for deterministic high-speed performance at this distance. As long as you stay within the 2-meter specification for this model, signal latency remains within system tolerances.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45913788842157,"sku":"YCB301-C200","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/YCB301.jpg?v=1776326562","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-ycb301-c200-esb-bus-cable-2m-36-36-pins-for-centum-vp-cs-3000","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}