{"product_id":"yokogawa-ycb301-c100-esb-bus-cable-1m-36-36-pins-for-centum-vp-dcs","title":"Yokogawa YCB301-C100 ESB Bus Cable 1m (36-36 pins) for CENTUM VP DCS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the backbone of high-speed data synchronization within the CENTUM VP Distributed Control System. This 1-meter ESB (Enhanced Service Bus) cable establishes a deterministic communication link between the Field Control Unit (FCU) and various node units, such as the ANB10 or ANB11. Engineered to handle the rigorous demands of real-time process automation, this cable ensures the millisecond-level precision required for complex control loops in power plants, refineries, and chemical processing facilities.\u003c\/p\u003e\n\u003cp\u003eUnlike standard interface cables, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a specialized shielded environment that protects vital process data from the high levels of electromagnetic interference (EMI) present in industrial motor control centers and server cabinets. Its 36-pin architecture supports high-bandwidth transmission, allowing the DCS to maintain constant surveillance over field I\/O while ensuring that safety and control commands reach their destination without latency or signal degradation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel follows a precise suffix logic that dictates its application and physical reach within a DCS cabinet or across adjacent racks.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e: Designates the primary ESB Bus Cable series featuring high-density 36-pin proprietary connectors at both terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-C100\u003c\/strong\u003e: Represents the fixed physical length of the assembly. The \"100\" indicates 1.0 meter (approximately 39.4 inches), providing the necessary slack for routing between non-adjacent node units or connecting modules across separate DIN rail sections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eYCB301-C100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36-pin to 36-pin High-Density Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Meter (3.28 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus \/ Enhanced Service Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCore Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP, CENTUM CS 3000, ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Transmission\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed Serial Differential Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding Efficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-layered braided shield for EMI\/RFI protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBending Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 45 mm (Avoid sharp kinks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg (approx. 1.0 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (Spool)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 25.0 cm x 5.0 cm (Coiled for shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eTo maintain the high-integrity communication of the ESB network, engineers must adhere to specific installation protocols for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C100\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ch3\u003eConnector Security\u003c\/h3\u003e\n\u003cp\u003eEnsure the 36-pin connectors are fully seated into the FCU or node unit socket. Use the integrated thumb-screws to lock the connection; a loose bus cable is the most common cause of \"Node Communication Error\" alarms. Hand-tighten only to avoid stripping the threads on the module backplane.\u003c\/p\u003e\n\u003ch3\u003eRouting and Bend Radius\u003c\/h3\u003e\n\u003cp\u003eWhile the 1-meter length allows for flexible routing, avoid running this bus cable parallel to high-voltage AC power lines. Maintain a minimum bending radius of 45 mm. Over-bending the cable can cause internal reflection of the data signal, leading to intermittent CRC errors in the system logs.\u003c\/p\u003e\n\u003ch3\u003eRedundancy Verification\u003c\/h3\u003e\n\u003cp\u003eIn a dual-redundant configuration, route the primary and secondary YCB301 cables through different paths within the cabinet if possible. This prevents a single mechanical impact from severing both communication lines simultaneously.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers superior durability compared to third-party alternatives. Its gold-plated contact pins prevent the micro-corrosion that often leads to intermittent failures in humid or chemically aggressive environments. The robust outer jacket resists abrasion and is flame-retardant, meeting the stringent safety requirements of global industrial sites. By utilizing this genuine Yokogawa cable, you ensure seamless compatibility with the DCS diagnostic suite, allowing the system to accurately report the health of the communication bus during operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDelivery and Logistics\u003c\/h2\u003e\n\u003cp\u003eWe prioritize rapid fulfillment for critical DCS infrastructure components.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFast global delivery by DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-sealed anti-static packaging ensures the cable arrives in pristine condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I link multiple YCB301-C100 cables together to increase the length?\u003c\/p\u003e\n\u003cp\u003eA1: No. ESB Bus cables must be a single, continuous run. To extend the bus beyond 1 meter, you should purchase the specific length required (e.g., C200 for 2 meters) or utilize ESB Bus Optical Repeater Modules for distances over 10 meters.\u003c\/p\u003e\n\u003cp\u003eQ2: Is this cable compatible with the older CENTUM CS 3000 systems?\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the YCB301 series is the standard connection for ESB nodes across both CENTUM CS 3000 and the modern CENTUM VP platforms.\u003c\/p\u003e\n\u003cp\u003eQ3: Does the cable support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA3: The cable hardware is robust, but the DCS software will trigger a system alarm if the bus is disconnected during operation. In redundant systems, you may replace one cable at a time while the other remains active.\u003c\/p\u003e\n\u003cp\u003eQ4: How do I identify a genuine YCB301-C100 from a counterfeit?\u003c\/p\u003e\n\u003cp\u003eA4: Genuine cables feature the Yokogawa logo molded into the connector housing and include a serialized tracking label on the cable jacket.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45913788088493,"sku":"YCB301-C100","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/YCB301.jpg?v=1776326562","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-ycb301-c100-esb-bus-cable-1m-36-36-pins-for-centum-vp-dcs","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}