{"product_id":"yokogawa-ycb301-c020-esb-bus-cable-20cm-36-36-pins-for-centum-vp","title":"Yokogawa YCB301-C020 ESB Bus Cable 20cm (36-36 pins) for CENTUM VP","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C020\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized high-speed communication cable engineered for the ESB (Enhanced Service Bus) architecture within the CENTUM VP and CS 3000 Distributed Control Systems. This 20 cm cable facilitates the critical interconnection between the Safety Control Unit and the Safety Node Unit, or between multiple I\/O nodes. Given its role in high-frequency data exchange, the YCB301-C020 utilizes premium shielding to maintain signal integrity against electromagnetic interference (EMI) commonly found in dense industrial cabinets.\u003c\/p\u003e\n\u003cp\u003eIn complex automation environments, the reliability of the bus connection determines the stability of the entire control loop. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C020\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a precision-molded 36-to-36 pin configuration that ensures low-latency communication and zero packet loss. Its short 20 cm length is specifically designed for adjacent module connections, reducing cable clutter and minimizing signal attenuation for high-speed synchronization between processor modules and I\/O expansion units.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C020\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a strict nomenclature that defines its physical and functional capabilities within the Yokogawa ecosystem.\u003c\/p\u003e\n\u003ch3\u003eSuffix Code Analysis\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e: The base model for the ESB Bus Cable, utilizing a 36-pin high-density interface designed specifically for Yokogawa’s proprietary communication backplanes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-C020\u003c\/strong\u003e: This suffix denotes the specific physical length of the cable. The \"020\" signifies a 20 cm (approximately 7.8 inches) span, which is the standard choice for vertically stacked node units or side-by-side rail mounting where minimal distance is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eYCB301-C020\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36-pin to 36-pin Proprietary Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm (0.2 Meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus (Enhanced Service Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ CS 3000 \/ ProSafe-RS Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density braided shield with EMI protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (Shipping)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 cm × 15.0 cm × 3.0 cm (Approximate)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg (0.55 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eProper handling of ESB bus cables is vital to prevent communication errors (Bus Faults). Follow these engineering guidelines:\u003c\/p\u003e\n\u003ch3\u003eConnector Alignment\u003c\/h3\u003e\n\u003cp\u003eThe 36-pin connectors are keyed to ensure correct orientation. Align the connector carefully before applying pressure. Tighten the integral retaining screws to ensure the cable remains seated during periods of mechanical vibration or thermal expansion.\u003c\/p\u003e\n\u003ch3\u003eBending Radius Limits\u003c\/h3\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C020\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for short-range connectivity, do not force the cable into sharp 90-degree turns. Maintain the minimum bending radius of 45 mm to avoid damaging the internal high-speed conductors or compromising the shielding.\u003c\/p\u003e\n\u003ch3\u003eRedundant Configuration\u003c\/h3\u003e\n\u003cp\u003eIn redundant ESB bus setups, ensure that Bus 1 and Bus 2 cables are routed clearly and labeled. Avoid tangling the two cables to simplify maintenance and to ensure that a physical impact on one cable does not necessarily affect the other.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C020\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis constructed with industrial-grade insulation and robust strain relief, making it far superior to standard communication cables. Its low-impedance design supports the high-speed requirements of real-time control, ensuring that safety-related signals and process variables are transmitted without lag. The gold-plated contact pins resist oxidation, ensuring a long-term, low-resistance connection even in environments with high humidity or corrosive trace gases. By using original Yokogawa cables, engineers maintain the system's E-E-A-T integrity and ensure full compliance with the DCS manufacturer's performance warranties.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDelivery and Logistics\u003c\/h2\u003e\n\u003cp\u003eWe provide expedited shipping for all Yokogawa communication accessories.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 business days following payment verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard delivery via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped in a sealed, anti-static bag protected by a rigid cardboard exterior to prevent connector damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I use a longer cable if 20 cm is too short for my cabinet layout?\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the YCB301 series is available in various lengths (e.g., C050 for 50 cm, C100 for 1 meter). However, you should use the shortest cable possible to maximize signal quality.\u003c\/p\u003e\n\u003cp\u003eQ2: Is the YCB301-C020 compatible with ProSafe-RS safety systems?\u003c\/p\u003e\n\u003cp\u003eA2: Yes, this cable is the standard interconnect for ESB bus communication in both CENTUM VP and ProSafe-RS safety instrumented systems.\u003c\/p\u003e\n\u003cp\u003eQ3: What should I do if the ESB Bus \"ERR\" LED lights up after installation?\u003c\/p\u003e\n\u003cp\u003eA3: First, check the tension on the retaining screws. Most bus errors are caused by loose connections. If the error persists, inspect the cable for any sharp kinks or internal conductor damage.\u003c\/p\u003e\n\u003cp\u003eQ4: Is this cable hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA4: While the cable is robust, removing an ESB bus cable while the system is live will cause a loss of communication to the downstream nodes. Only perform swaps on redundant systems where the secondary bus is confirmed healthy.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45913782517933,"sku":"YCB301-C020","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/YCB301.jpg?v=1776326562","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-ycb301-c020-esb-bus-cable-20cm-36-36-pins-for-centum-vp","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}