{"product_id":"yokogawa-vc401-11-vnet-ip-coupler-module-for-sequence-of-events-manager","title":"Yokogawa VC401-11 Vnet\/IP Coupler Module for Sequence of Events Manager","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Yokogawa VC401-11 is a specialized Coupler Module designed for the Sequence of Events Manager (SEM) within the Vnet\/IP environment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis high-precision hardware component is engineered to capture and record discrete signal changes across a distributed control system with sub-millisecond accuracy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy providing a 1-millisecond resolution for event timestamps,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe VC401-11 allows engineers to perform detailed root-cause analysis following plant trips,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eequipment failures,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor process upsets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eAs a bridge between field data and the supervisory network,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe VC401-11 ensures that Sequence of Events (SOE) data is synchronized across the entire system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt eliminates the need for complex external clock hardware by leveraging Vnet\/IP time synchronization protocols and optional SNTP server integration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that all recorded events are chronologically aligned across multiple stations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVC401-11\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCoupler Module (SEM Support)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVnet\/IP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTimestamp Resolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1 millisecond\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e32 mm x 143 mm x 130 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e20 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Consumption:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e250 mA at 5 V DC (Typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 to 50°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20 to 70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5 to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Monitoring and Control:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe VC401-11 allows SOE inputs to be utilized simultaneously for real-time control logic and high-speed event recording,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaximizing the utility of field wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAdvanced Data Management:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports the automated generation of trip reports and maintains a robust historical buffer.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eData is easily accessible for higher-level plant information management systems (PIMS) such as Exaquantum.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnified Alarm Architecture:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt facilitates the integration of SOE messages directly into the standard process alarm windows of Human Interface Stations (HIS),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding operators with a cohesive timeline of system behavior.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Scalability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for seamless deployment in power plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoil refineries,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand chemical processing facilities where precise sequence monitoring of turbines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecompressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand emergency shutdown (ESD) systems is mandatory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45519066661037,"sku":"VC401-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/yokogawa-vc401-11-coupler-module-murxrud4rz3.jpg?v=1766986058","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-vc401-11-vnet-ip-coupler-module-for-sequence-of-events-manager","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}