{"product_id":"yokogawa-sdv144-s13-prosafe-rs-16-channel-digital-input-module","title":"Yokogawa SDV144-S13 ProSafe-RS 16-Channel Digital Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Yokogawa ADV151-P00 S2 combined with the ATD5A-00 interface adapter is a high-density discrete signal acquisition solution for the CENTUM VP Distributed Control System (DCS).\u003c\/span\u003e\u003cspan class=\"\"\u003e This specific assembly is designed for the FIO (Field Interface Orbus) architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing 32 isolated digital input channels to monitor field states such as contact closures,\u003c\/span\u003e\u003cspan class=\"\"\u003e switch positions,\u003c\/span\u003e\u003cspan class=\"\"\u003e and logic levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe \"P00\" designation indicates a module configured for KS cable connectivity,\u003c\/span\u003e\u003cspan class=\"\"\u003e which is facilitated by the included ATD5A-00 adapter.\u003c\/span\u003e\u003cspan class=\"\"\u003e This combination allows for a clean,\u003c\/span\u003e\u003cspan class=\"\"\u003e modular connection to field terminal boards using standardized multi-core cables,\u003c\/span\u003e\u003cspan class=\"\"\u003e significantly reducing the manual wiring requirements within the control cabinet.\u003c\/span\u003e\u003cspan class=\"\"\u003e As an \"S2\" enhanced version,\u003c\/span\u003e\u003cspan class=\"\"\u003e it offers superior signal conditioning and high-speed data refresh rates required for modern,\u003c\/span\u003e\u003cspan class=\"\"\u003e deterministic process control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Yokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e ADV151-P00 S2 \/ ATD5A-00\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Digital Input Module with KS Cable Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Channels:\u003c\/strong\u003e\u003cspan class=\"\"\u003e 32 channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e isolated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Signal:\u003c\/strong\u003e\u003cspan class=\"\"\u003e 24 V DC (Dry contact support)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInterface Style:\u003c\/strong\u003e\u003cspan class=\"\"\u003e KS Cable interface via ATD5A-00 adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eData Refresh Cycle:\u003c\/strong\u003e\u003cspan class=\"\"\u003e 10 ms or less\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWithstand Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e 1500 V AC (Field to System logic)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Supply:\u003c\/strong\u003e\u003cspan class=\"\"\u003e 24 V DC (External) and 5 V DC (System bus)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e IP20 rated enclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e -20°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e 32.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 mm x 106.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 mm x 130 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e24 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Japan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Density Signal Processing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Efficiently manages 32 discrete input points in a single FIO slot,\u003c\/span\u003e\u003cspan class=\"\"\u003e maximizing I\/O density and reducing the overall hardware footprint in the Field Control Station (FCS).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModular Interface Design:\u003c\/strong\u003e\u003cspan class=\"\"\u003e The integration of the ATD5A-00 adapter enables the use of pre-assembled KS cables,\u003c\/span\u003e\u003cspan class=\"\"\u003e facilitating \"plug-and-play\" connectivity between the module and remote terminal blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSuperior Galvanic Isolation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Employs 1500 V AC isolation to protect the DCS internal backplane and CPU from field-side electrical surges,\u003c\/span\u003e\u003cspan class=\"\"\u003e ground loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e and high-frequency interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDeterministic Scan Times:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Engineered with a high-speed data refresh cycle of 10 ms,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring that critical binary state changes in the process are captured and processed by the control logic without delay.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRuggedized Industrial Build:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Features an extended operating temperature range and high-grade internal components designed for continuous duty in refineries,\u003c\/span\u003e\u003cspan class=\"\"\u003e chemical plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e and offshore platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFault-Tolerant Redundancy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e Fully supports dual-redundant configurations.\u003c\/span\u003e\u003cspan class=\"\"\u003e In a paired setup,\u003c\/span\u003e the modules provide bumpless signal acquisition, maintaining process visibility even during a hardware failure or maintenance cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45519049261229,"sku":"SDV144-S13","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/yokogawa-sdv144-s13-digital-input-module-252iovqamvi.jpg?v=1766985742","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-sdv144-s13-prosafe-rs-16-channel-digital-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}