{"product_id":"yokogawa-pw482-50-power-supply-module","title":"Yokogawa PW482-50 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa PW482-50\u003c\/strong\u003e is a 220–240 VAC input power supply module designed for dedicated installation in compatible Yokogawa control-system units. It supplies power through an exclusive system connector and can be used in single or dual-redundant configurations, depending on the host unit. The module is designed for FCUs, FIO Node Units, and Optical ESB Bus Repeater Units.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PW482 is Yokogawa's 220–240 VAC input power supply module. Its suffix codes identify the protection type and environmental option.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePW482\u003c\/td\u003e\n\u003ctd\u003e220–240 VAC input power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-5\u003c\/td\u003e\n\u003ctd\u003eStandard type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-E\u003c\/td\u003e\n\u003ctd\u003eStandard type with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, with operating temperature range of -20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe supplied model identifier \u003cstrong\u003ePW482-50\u003c\/strong\u003e combines the -5 standard type code and 0 basic type code. Confirm the complete nameplate and ordering documentation before selecting a replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW482-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220–240 VAC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output Interface\u003c\/td\u003e\n\u003ctd\u003eExclusive system connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDedicated power supply slot in compatible Yokogawa units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Configuration\u003c\/td\u003e\n\u003ctd\u003eTwo identical modules with the same model code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eStandard type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eDedicated Power Supply and Backplane Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PW482 is designed specifically for Yokogawa FCU, FIO Node Unit, and Optical ESB Bus Repeater Unit assemblies. It connects through an exclusive system connector rather than a general-purpose output terminal arrangement.\u003c\/p\u003e\n\u003cp\u003eYokogawa does not specify the module's output voltage and current as general-purpose power supply ratings. The PW482 must therefore be treated as a system-specific module, not as a standalone DC power supply for arbitrary external loads.\u003c\/p\u003e\n\u003cp\u003eThe module's maximum power consumption is 230 VA for the 220–240 VAC input version.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDual-Redundant Power Supply Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCompatible host units can use two power supply modules to establish a dual-redundant configuration. Yokogawa specifies that both modules must have identical model codes.\u003c\/p\u003e\n\u003cp\u003eFor supported base plates, power supply modules occupy slots P1 and P2. When a single power supply module is used, it must be installed in slot P1.\u003c\/p\u003e\n\u003cp\u003eThe redundancy arrangement depends on the host unit and its system configuration. Confirm the applicable hardware documentation before replacing or changing the installed power supply configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Electrical Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PW482 uses a dedicated connector and must be installed in a compatible Yokogawa unit. It is not intended for direct connection to external loads through generic DC output terminals.\u003c\/p\u003e\n\u003cp\u003eInstallation checks include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the host unit supports the PW482 model.\u003c\/li\u003e\n\u003cli\u003eConfirm that the supply voltage is within 220–240 VAC ±10%.\u003c\/li\u003e\n\u003cli\u003eCheck the 50\/60 Hz input frequency and the applicable installation requirements.\u003c\/li\u003e\n\u003cli\u003eInstall the module in the designated power supply slot.\u003c\/li\u003e\n\u003cli\u003eFor dual-redundant operation, use two identical modules with matching model codes.\u003c\/li\u003e\n\u003cli\u003eIsolate the power source before removing or installing the module.\u003c\/li\u003e\n\u003cli\u003eFollow the host unit's installation instructions for mechanical retention and electrical safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume that a PW482-50 can replace another suffix variant without checking the protection type, environmental option, and host-system requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e- Q: What is the input voltage of the Yokogawa PW482-50?\u003c\/p\u003e\n\u003cp\u003eA: The PW482 model accepts 220–240 VAC input with a rated tolerance of ±10%.\u003c\/p\u003e\n\u003cp\u003e- Q: What is the input frequency?\u003c\/p\u003e\n\u003cp\u003eA: The specified input frequency is 50\/60 Hz with a tolerance of ±3 Hz.\u003c\/p\u003e\n\u003cp\u003e- Q: What is the maximum power consumption?\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa specifies a maximum power consumption of 230 VA for the PW482 220–240 VAC input model.\u003c\/p\u003e\n\u003cp\u003e- Q: Does the PW482 provide standard 24 VDC output terminals?\u003c\/p\u003e\n\u003cp\u003eA: No general-purpose output voltage or current rating is specified. The module uses an exclusive connector for compatible Yokogawa units.\u003c\/p\u003e\n\u003cp\u003e- Q: Can two PW482 modules be used together?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Compatible host units support dual-redundant power configurations using two identical modules with the same model code.\u003c\/p\u003e\n\u003cp\u003e- Q: Where is the PW482 installed?\u003c\/p\u003e\n\u003cp\u003eA: It is designed for installation in compatible FCUs, FIO Node Units, and Optical ESB Bus Repeater Units.\u003c\/p\u003e\n\u003cp\u003e- Q: What is the approximate weight of the PW482?\u003c\/p\u003e\n\u003cp\u003eA: The manufacturer's general specification lists an approximate module weight of 1 kg.\u003c\/p\u003e\n\u003cp\u003e- Q: Is PW482-50 explosion protected?\u003c\/p\u003e\n\u003cp\u003eA: The -5 suffix denotes the standard type without explosion protection. Confirm the complete ordering code for the required installation environment.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68368001695917,"sku":"PW482-50","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/PW482-50S24.jpg?v=1795083496","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-pw482-50-power-supply-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}