{"product_id":"yokogawa-asi133-h00-current-input-module-4-20ma-8-channel","title":"Yokogawa ASI133-H00 Current Input Module 4-20mA 8-Channel","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ASI133-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCurrent Input Module serves as a critical interface for high-precision process monitoring in heavy industrial environments. By supporting 8 isolated channels of 4-20 mA signals, this module captures vital data from pressure transmitters, flowmeters, and analytical sensors used in the protection of rotating machinery and complex chemical loops. It features integrated HART communication, allowing engineers to perform remote diagnostics and device configuration without interrupting the primary signal path. Designed for the CENTUM series architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a 1500 V AC withstanding voltage, shielding the control system logic from field-side electrical surges. This module ensures that even the most subtle process fluctuations are digitized with ±16 µA accuracy, maintaining the operational safety of high-value assets like steam turbines and centrifugal compressors.\u003c\/p\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a specific suffix structure to define its communication capabilities and hardware protection levels.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Analysis: ASI133-H00\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eASI133\u003c\/strong\u003e: This represents the fundamental Current Input Module series, optimized for 8-channel analog acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-H\u003c\/strong\u003e: Indicates that the module is equipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapabilities, enabling digital data overlays on the 4-20 mA analog signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0\u003c\/strong\u003e: Denotes a standard hardware configuration without specialized safety-certified coatings (Non-ISA G3).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0\u003c\/strong\u003e: Specifies a standard mounting and terminal interface, typically compatible with the ATSA3 pressure clamp terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eASI133-H00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels, Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±16 µA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStep Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC (Input to Logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmitter Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.0 V DC or higher\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHART Communication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported (Bi-directional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mA (5V) \/ 450 mA (24V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (Approx)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33 mm x 130 mm x 128 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers industrial-grade durability that outperforms standard commercial I\/O components. Its isolated channel architecture prevents ground loops from propagating through the system, a feature essential for plants with extensive grounding networks. The module's impressive temperature drift resistance (±16 µA\/10 °C) ensures measurement stability in non-climate-controlled field enclosures.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module includes a built-in current limiter (22.5 mA) and short-circuit protection for transmitter power. If a field device fails or a cable shorts, the module limits the current to prevent damage to the backplane or adjacent modules. This resilience makes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe preferred choice for applications in offshore platforms, refineries, and power generation facilities where reliability is non-negotiable.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eCorrect installation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures optimal signal clarity and system uptime.\u003c\/p\u003e\n\u003ch3\u003eWiring and Terminal Selection\u003c\/h3\u003e\n\u003cp\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATSA3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epressure clamp terminal for secure physical connections. For 2-wire transmitters, the module supplies power directly; for 4-wire transmitters, ensure the external power source does not exceed the 25 V normal mode limit to prevent input saturation.\u003c\/p\u003e\n\u003ch3\u003eNoise Mitigation\u003c\/h3\u003e\n\u003cp\u003eRoute 4-20 mA signal cables away from high-voltage AC motor leads. Utilize twisted-pair shielded cables (TPS) and terminate the shield at the cabinet's functional earth bar. This practice prevents electromagnetic interference (EMI) from degrading the high-speed 10 ms data update integrity.\u003c\/p\u003e\n\u003ch3\u003eThermal Management\u003c\/h3\u003e\n\u003cp\u003eEnsure adequate airflow within the FIO nest. Although the module operates up to 70°C, maintaining a lower ambient temperature within the cabinet significantly extends the life of the internal optoisolators and capacitors.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the ASI133-H00 require an external power supply for transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The module provides an internal transmitter power supply of at least 16 V DC for 2-wire loops. However, it also supports 4-wire transmitters that utilize their own external power sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does the HART communication function on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The module acts as a HART master or gateway, allowing the DCS to read secondary variables (like sensor temperature) and diagnostic status bits directly through the 4-20 mA wiring without extra cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I replace an older ASI133 module with the H00 version while the system is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: If the DCS rack is configured for redundancy and the software supports hot-swapping, you can replace the module live. Ensure the \"Ready\" LED is in the correct state before physical removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What happens if the input signal exceeds 20 mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The module allows for an over-range signal up to 22.5 mA. If the current exceeds this threshold, the internal protection circuitry engages to safeguard the hardware from thermal overload.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45897965174957,"sku":"ASI133-H00","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/yokogawa_asi133-H00_1.jpg?v=1775702489","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-asi133-h00-current-input-module-4-20ma-8-channel","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}