{"product_id":"yokogawa-anr10d-420-er-bus-node-unit-for-fio","title":"Yokogawa ANR10D-420 ER Bus Node Unit for FIO","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANR10D\u003c\/strong\u003e is an ER Bus Node Unit for Field Network I\/O (FIO) systems. It operates as a remote node, connecting to an \u003cstrong\u003eEB401 ER Bus Interface Master Module\u003c\/strong\u003e installed in a local node or compatible Field Control Unit. The dual-redundant ANR10D configuration accommodates two power supply modules and two EB501 ER Bus Interface Slave Modules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANR10D is Yokogawa's 19-inch rack-mountable remote node unit for a dual-redundant ER bus. Its ordering configuration determines the power supply arrangement, input voltage, and protection type.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDocumented Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANR10D\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ER Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220–240 VAC power supply, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/ATDOC\u003c\/td\u003e\n\u003ctd\u003eExplosion Protection Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eSoftware license for node expansion; required for connection with AFF50 or AFV10 field control stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering code note:\u003c\/strong\u003e The supplied identifier ANR10D-420 does not align fully with the suffix sequence in the manufacturer's published model table. Confirm the complete nameplate and ordering code before treating the final 0 as a documented protection-type suffix.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANR10D-420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eER Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eField Network I\/O (FIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ER bus remote node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e220–240 VAC, 50\/60 Hz, based on supplied model description\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA, 120 W at 220–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eTwo power supply modules for dual-redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eER Bus Interface\u003c\/td\u003e\n\u003ctd\u003eTwo EB501 slave modules for dual-redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eER Bus Master Interface\u003c\/td\u003e\n\u003ctd\u003eEB401 installed in the local node or compatible FCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 4 × M5 mounting screw holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003eApprox. 482.6 × 221.5 × 205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg including 8 I\/O modules, as stated in the general specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eER Bus Communication and Remote Node Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANR10D functions as a remote node in Yokogawa's FIO architecture. It connects to an ER Bus Interface Master Module, model EB401, installed in a local node or compatible Field Control Unit.\u003c\/p\u003e\n\u003cp\u003eThe remote node uses EB501 ER Bus Interface Slave Modules to establish the node-side ER bus interface. In a dual-redundant configuration, two EB501 modules are installed.\u003c\/p\u003e\n\u003cp\u003eThe node unit also accommodates the power supply and I\/O modules required by the configured field interface. This architecture allows remote I\/O modules to communicate with the control system through the ER bus.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Redundancy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANR10D supports a dual-redundant power supply arrangement. Two power supply modules are installed when this configuration is selected.\u003c\/p\u003e\n\u003cp\u003eFor the 220–240 VAC supply option, Yokogawa specifies a power consumption of 230 VA and 120 W. The supply frequency is 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003eThe power supply modules provide power to the installed I\/O modules and field transmitters. The power supply terminals use M4 screws.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Electrical Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ANR10D is designed for 19-inch rack mounting. The manufacturer's external-dimension drawing identifies four M5 mounting screw holes.\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the complete model and suffix code against the equipment nameplate.\u003c\/li\u003e\n\u003cli\u003eCheck that the selected power supply modules match the specified 220–240 VAC input.\u003c\/li\u003e\n\u003cli\u003eConfirm the dual-redundant arrangement and the required number of power supply modules.\u003c\/li\u003e\n\u003cli\u003eInstall the EB501 slave modules according to the selected ER bus configuration.\u003c\/li\u003e\n\u003cli\u003eVerify that the local node or compatible FCU contains the required EB401 master module.\u003c\/li\u003e\n\u003cli\u003eFollow Yokogawa's FIO installation limitations and cabinet environmental requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer's documentation specifies that I\/O module quantity and allocation are subject to installation restrictions. Where modules with built-in barriers are installed, an insulating partition, part number T9083NA, is required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e- Q: What is the main function of the Yokogawa ANR10D?\u003c\/p\u003e\n\u003cp\u003eA: It serves as a remote FIO node, connecting field I\/O modules to a local node or compatible FCU through the ER bus.\u003c\/p\u003e\n\u003cp\u003e- Q: Is the ANR10D designed for a dual-redundant ER bus?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The ANR10D is the dual-redundant ER Bus Node Unit in the Yokogawa FIO node family.\u003c\/p\u003e\n\u003cp\u003e- Q: Which master interface module connects to the ANR10D?\u003c\/p\u003e\n\u003cp\u003eA: The EB401 ER Bus Interface Master Module is installed in the local node or compatible FCU.\u003c\/p\u003e\n\u003cp\u003e- Q: Which slave interface modules are used in the ANR10D?\u003c\/p\u003e\n\u003cp\u003eA: The EB501 ER Bus Interface Slave Module is used. Two EB501 modules are installed for a dual-redundant configuration.\u003c\/p\u003e\n\u003cp\u003e- Q: What is the power input for the 220–240 VAC version?\u003c\/p\u003e\n\u003cp\u003eA: The specified input is 220–240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003e- Q: What is the power consumption at 220–240 VAC?\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa specifies 230 VA and 120 W for the 220–240 VAC power supply option.\u003c\/p\u003e\n\u003cp\u003e- Q: How is the ANR10D mounted?\u003c\/p\u003e\n\u003cp\u003eA: It is designed for 19-inch rack mounting and uses four M5 mounting screw holes.\u003c\/p\u003e\n\u003cp\u003e- Q: Can the ANR10D be used with any Yokogawa FCU?\u003c\/p\u003e\n\u003cp\u003eA: No universal compatibility is established. Confirm the FCU model, FIO architecture, EB401 interface, and system configuration before installation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68367915286701,"sku":"ANR10D-420","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/anr10d-420_1.jpg?v=1795082922","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-anr10d-420-er-bus-node-unit-for-fio","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}