{"product_id":"yokogawa-adv151-p00-s2-32-channel-digital-input-module","title":"Yokogawa ADV151-P00 S2 32-Channel Digital Input Module","description":"\u003cp\u003eThe Yokogawa ADV151-P00 S2 is a 32-channel isolated digital input module designed for Yokogawa Fieldbus I\/O (FIO) systems. It receives 24 V DC ON\/OFF signals from industrial field devices, including switches, pushbuttons, and status contacts. The module supports status detection and pushbutton edge counting, providing flexible signal acquisition for distributed control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e32 isolated digital input channels\u003c\/li\u003e\n\u003cli\u003eRated input voltage of 24 V DC\u003c\/li\u003e\n\u003cli\u003eSupports sink and source input configurations\u003c\/li\u003e\n\u003cli\u003eInput ON voltage: 18–26.4 V DC\u003c\/li\u003e\n\u003cli\u003eInput OFF voltage: 5.0 V DC or less\u003c\/li\u003e\n\u003cli\u003eStatus input function for ON\/OFF detection\u003c\/li\u003e\n\u003cli\u003ePushbutton input function for edge counting\u003c\/li\u003e\n\u003cli\u003eInput response time of 8 ms or less for status input\u003c\/li\u003e\n\u003cli\u003eSupports dual-redundant configurations\u003c\/li\u003e\n\u003cli\u003eCompatible with designated Yokogawa FIO systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P00 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eYokogawa FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e24 V DC ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSink \/ Source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18–26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA ±20% per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less for status input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePushbutton Minimum ON Detection Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pushbutton ON\/OFF Cycle\u003c\/td\u003e\n\u003ctd\u003e25 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Functions\u003c\/td\u003e\n\u003ctd\u003eStatus detection and pushbutton edge counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Common Configuration\u003c\/td\u003e\n\u003ctd\u003eCommon every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput-to-System Withstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute, subject to connection method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-to-Common Withstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, dedicated AKB331 cable, or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.75 × 3.28 × 13.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003e32-Channel Digital Input Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-P00 S2 provides 32 digital input channels for collecting ON\/OFF signals from field devices. It is designed for 24 V DC signal acquisition in industrial automation systems.\u003c\/p\u003e\n\u003cp\u003eThe module supports both sink and source input configurations. Its input ON voltage range is 18–26.4 V DC, while signals at 5.0 V DC or below are recognized as OFF.\u003c\/p\u003e\n\u003cp\u003eEach channel draws approximately 4.1 mA at the rated input voltage. The maximum allowable input voltage is 30.0 V DC.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Input and Pushbutton Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151 supports two input functions: status input and pushbutton input.\u003c\/p\u003e\n\u003cp\u003eThe status input function detects ON\/OFF conditions from connected field devices. Its specified input response time is 8 ms or less.\u003c\/p\u003e\n\u003cp\u003eThe pushbutton input function counts signal edges, making it suitable for pushbutton operation and event-counting applications. The minimum ON detection time is 20 ms, with a maximum ON\/OFF cycle of 25 Hz.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Common Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151 provides electrical isolation between input signals and the system. Its documented withstand voltage is 2 kV AC for one minute under specified test conditions.\u003c\/p\u003e\n\u003cp\u003eThe input channels are arranged in two groups, with a common shared by every 16 channels. The withstand voltage between commons is specified as 500 V AC for one minute.\u003c\/p\u003e\n\u003cp\u003eAll 24 V DC input signals connected to the module must use the same polarity. Wiring and grounding should follow the applicable Yokogawa installation documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ADV151 digital input module is designed for Yokogawa FIO system architectures. Compatible installation platforms include designated ESB bus node units, optical ESB bus node units, ER bus node units, and field control units.\u003c\/p\u003e\n\u003cp\u003eBefore ordering a replacement, verify the exact system node, module suffix, hardware configuration, and connection interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCheck the complete model number and suffix on the module nameplate.\u003c\/li\u003e\n\u003cli\u003eConfirm the compatible ESB, ER, or field control unit.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 V DC field supply and input polarity.\u003c\/li\u003e\n\u003cli\u003eCheck the common arrangement for channels 1–16 and 17–32.\u003c\/li\u003e\n\u003cli\u003eSelect the correct status or pushbutton input function.\u003c\/li\u003e\n\u003cli\u003eConfirm the applicable terminal or cable interface.\u003c\/li\u003e\n\u003cli\u003eCheck channel status and system diagnostics after installation.\u003c\/li\u003e\n\u003cli\u003ePerform functional testing before returning equipment to operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas process facilities\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical plants\u003c\/li\u003e\n\u003cli\u003ePower generation and utilities\u003c\/li\u003e\n\u003cli\u003eIndustrial manufacturing lines\u003c\/li\u003e\n\u003cli\u003ePump and motor status monitoring\u003c\/li\u003e\n\u003cli\u003eLimit switch and proximity switch monitoring\u003c\/li\u003e\n\u003cli\u003ePushbutton signal acquisition\u003c\/li\u003e\n\u003cli\u003eDistributed control system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Genuine Yokogawa Replacement Modules\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelecting the correct Yokogawa digital input module helps maintain consistency with the installed FIO architecture. Accurate model identification is important for matching input voltage, channel configuration, connection interfaces, and redundancy requirements.\u003c\/p\u003e\n\u003cp\u003eBefore selecting a replacement, compare the complete part number and module nameplate. Also verify the field wiring arrangement and system compatibility to reduce commissioning risks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Yokogawa ADV151-P00 S2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a 32-channel isolated digital input module designed to receive 24 V DC ON\/OFF signals in compatible Yokogawa FIO systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many input channels does the ADV151 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ADV151 provides 32 digital input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What input voltage does the ADV151-P00 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIts rated input voltage is 24 V DC, with sink and source input configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What are the input ON and OFF voltage thresholds?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified ON voltage is 18–26.4 V DC. The OFF voltage is 5.0 V DC or less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Does the ADV151 support pushbutton input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ADV151 supports pushbutton edge counting in addition to standard ON\/OFF status detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Can the ADV151 be used in a redundant system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ADV151 supports dual-redundant configurations when installed in a compatible Yokogawa system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Which connection interfaces are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDocumented options include pressure clamp terminals, dedicated AKB331 cables, and MIL connector cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What should I verify before purchasing a replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the complete part number, input voltage, channel configuration, common polarity, terminal or cable interface, and compatibility with the existing Yokogawa FIO system.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68376401019053,"sku":"ADV151-P00","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/adv151-p00_3.jpg?v=1795139003","url":"https:\/\/www.maxwellplc.com\/products\/yokogawa-adv151-p00-s2-32-channel-digital-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}