{"product_id":"xv-c904-a101-3bhe015412r0101-abb-pcb-board","title":"XV C904 A101 3BHE015412R0101 ABB PCB Board","description":"\u003cp\u003eConfigured for power distribution and voltage regulation in DCS architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB XV C904 A101 3BHE015412R0101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eXV C904 A101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePCB Board) provides direct electrical execution for 24 VDC power management.\u003c\/p\u003e\n\u003ch3\u003eComponent Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eXV C904 A101\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3BHE015412R0101\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePCB Board (Power Supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXV C904 A101 (3BHE015412R0101)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e37.6 x 14.0 x 7.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult system environmental rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNominal 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet router capabilities\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe XV C904 A101 maintains backplane bus communication velocity via integrated ethernet routing functions. The unit supports I\/O density scaling within DCS cabinets, ensuring that power distribution logic remains synchronized with the central control system. Firmware flash compatibility is managed through the onboard interface, allowing for system-level updates without disconnecting the hardware from the DIN-rail mounting.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) XV C904 A101 PCB Board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail mounting hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical safety and compliance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the board to a standard DIN-rail within an industrial enclosure; ensure horizontal orientation to maintain thermal dissipation performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the chassis ground terminal directly to the cabinet earthing busbar to prevent electrical disturbances and ensure EMC compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate power input leads following specified terminal torque values to prevent loose contacts during mechanical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the integrated LEDs for real-time health monitoring of the power regulation circuits; verify status indicators match expected operational states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the XV C904 A101 hot-swappable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the module requires power isolation before removal or insertion from the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it provide 24 VDC output?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the unit is designed to regulate and distribute 24 VDC to connected control system components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the Ethernet port?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt serves as a router for communication within the DCS network, facilitating data exchange between control segments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I perform a firmware update?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpdates are processed through the Ethernet interface; ensure the host controller software version supports the specific hardware revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the unit sensitive to input voltage fluctuations?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt includes internal protection circuits to maintain steady output during minor fluctuations in the 24 VDC supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module monitor its own health?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it features diagnostic LEDs and remote monitoring capabilities for predictive maintenance feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I mount this board?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed for standard DIN-rail installation within industrial automation cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions are required for high-vibration sites?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure all terminal connections are secured with appropriate locking washers and the board is firmly latched onto the DIN-rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231155052717,"sku":"3BHE015412R0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-xv-c904-a101-3bhe015412r0101-pcb-board-xuz1d12tnm2_3df2e35d-8e0e-49c4-97bf-c47572ac8a2d.jpg?v=1762942138","url":"https:\/\/www.maxwellplc.com\/products\/xv-c904-a101-3bhe015412r0101-abb-pcb-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}