{"product_id":"xf801-3bse061579r1-abb-communication-modules-800xa","title":"XF801 3BSE061579R1 ABB Communication Modules 800xA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eXF801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE061579R1\u003c\/strong\u003e)\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommunication Modules\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eXF801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommunication Modules\u003c\/strong\u003e, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This module is configured as a fast I\/O interface utilizing the PROFIBUS DP protocol, enabling high-speed data exchange between field instrumentation and the Advant OCS or System 800xA distributed control systems. The device provides the deterministic communication link necessary for high-density I\/O traffic, ensuring consistent process monitoring and control loop stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXF801 (3BSE061579R1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.5 x 16 x 8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 12 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC (Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBrand-Specific Technical Block\u003c\/h3\u003e\n\u003cp\u003eThe XF801 is integrated into the 800xA system via backplane communication buses, facilitating deterministic network data throughput. It supports I\/O density scaling by acting as a high-speed node on the PROFIBUS DP network, with data processing managed through firmware flash compatibility consistent with ABB control platform standards. The module provides multi-stage galvanic isolation (1500 V AC to backplane), mitigating common-mode noise interference typical in high-density automation cabinets. Deterministic network communication is maintained at 12 Mbps, ensuring that I\/O scan cycles are synchronized with the central controller's processing tasks without performance degradation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIncluded items: XF801 interface module, terminal connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard package: Industrial electrostatic protective anti-static housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional accessories: PROFIBUS shielded cable kits, replacement terminal blocks, diagnostic interface bridge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Cycle: Isolate field power and DCS rack power before module insertion to avoid backplane communication errors or electrical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Seat the XF801 onto the DIN rail, ensuring the locking latch is fully engaged for mechanical stability and vibration resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the module’s chassis ground point to the cabinet functional earth rail using a low-impedance conductor to satisfy EMC requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use PROFIBUS-certified shielded twisted-pair cabling. Maintain separation from high-voltage AC lines to prevent inductive noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure 360-degree shielding at cable entry points to the cabinet to maintain the integrity of the PROFIBUS signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: Install in enclosures maintaining an ambient temperature between -25 and 60 deg C; avoid direct humidity condensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the XF801 support hot-swap behavior?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is subject to the specific DCS rack configuration. Consult the System 800xA hardware manual for slot-specific hot-swap capabilities.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module impact backplane load?\u003c\/p\u003e\n\u003cp\u003eA: The XF801 consumes a maximum of 5 W; ensure the total rack power budget is sufficient before adding the module to existing backplane arrays.\u003c\/p\u003e\n\u003cp\u003eQ: Is there a redundancy switching delay?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy switching timing is governed by the host controller software; the module itself provides deterministic data propagation.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware compatibility required?\u003c\/p\u003e\n\u003cp\u003eA: Yes, firmware revisions must be validated against the System 800xA controller software to ensure reliable network communication.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit provide signal isolation?\u003c\/p\u003e\n\u003cp\u003eA: The XF801 provides 1500 V AC isolation between the field channels and the backplane, protecting internal control logic from transients.\u003c\/p\u003e\n\u003cp\u003eQ: What are the field wiring constraints?\u003c\/p\u003e\n\u003cp\u003eA: Wiring must adhere to PROFIBUS DP standards, including cable length limitations based on the chosen baud rate (up to 12 Mbps).\u003c\/p\u003e\n\u003cp\u003eQ: Can the PROFIBUS address be configured on the module?\u003c\/p\u003e\n\u003cp\u003eA: Address configuration is handled through the system engineering station and mapped to the module during software commissioning.\u003c\/p\u003e\n\u003cp\u003eQ: How are communication faults diagnosed?\u003c\/p\u003e\n\u003cp\u003eA: Communication status is transmitted to the host DCS, where it is mapped to system diagnostic registers accessible via the engineering workstation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231159771309,"sku":"3BSE061579R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-xf801-3bse061579r1-fast-i-o-module-gbtimc5bnmx_16603f26-9fe8-4e76-9701-b101438ed0cf.jpg?v=1762942175","url":"https:\/\/www.maxwellplc.com\/products\/xf801-3bse061579r1-abb-communication-modules-800xa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}