{"product_id":"woodward-9907-252-load-sharing-module-24vdc-industrial-control-unit","title":"Woodward 9907-252 Load Sharing Module | 24VDC Industrial Control Unit","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 9907-252\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical intelligence layer for proportional load sharing among parallel-connected generator sets. Engineered for high-reliability industrial power plants, this module precisely manages the distribution of kilowatts across multiple units, preventing circulating currents and ensuring system stability. It integrates seamlessly with electronic governors to provide proportional load sharing for engines equipped with speed controllers. By utilizing a solid-state hardware architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-252\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the mechanical wear associated with older relay-based systems, offering sub-millisecond response times essential for protecting sensitive downstream electrical loads in mission-critical facilities like data centers and oil rigs.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-252\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture emphasizes universal compatibility and rugged environmental resilience. This module interfaces directly with the Woodward SPM-A synchronizer, allowing for fully automated transitions from standby to parallel operation.\u003c\/p\u003e\n\u003cp\u003eThe device features an internal circular-buffer circuit that stabilizes frequency fluctuations during sudden load steps. Its analog input\/output logic supports a 0-3 Vdc load sharing line, which creates a common communication bus between all participating generators in the lineup. This \"droop-less\" isochronous load sharing capability allows the system to maintain a constant frequency regardless of the total load demand. Furthermore, the hardened chassis design ensures electromagnetic interference (EMI) protection, which is vital when installed in close proximity to high-output alternators and switching gear.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9907-252\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18-32 Vdc (24 Vdc Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 5 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e273.6 mm x 59.2 mm x 214.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 1.2 kg (2.65 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDroop Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 11% Adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePT Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95-130 Vac (Line to Line)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCT Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-7 Arms at Full Load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to 70°C (-40°F to 158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cp\u003eProper installation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 9907-252\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis paramount to preventing load oscillations. Engineers should ensure that the Current Transformer (CT) polarity is strictly observed; reversed CT wiring will lead to immediate reverse-power trips or erratic load distribution.\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum clearance of 50mm around the module for natural convection cooling. All signal wiring, particularly the load sharing lines and the CT\/PT inputs, must utilize twisted-pair shielded cables to prevent noise induction. The shield should be grounded only at the control cabinet end to avoid ground loops. When commissioning, verify the \"Lube Oil Pressure\" or \"Run\" interlock is correctly wired to the module to prevent the load sharing logic from activating before the engine reaches rated speed.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-252\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in extreme environments, maintaining its calibration even when exposed to high-vibration engine skids. Its wide operating temperature range makes it the preferred choice for remote power stations in arctic or desert climates. Unlike generic alternatives, this module provides a linear load-sharing signal that is natively compatible with the entire Woodward ecosystem, ensuring a \"plug-and-play\" experience for technicians upgrading legacy analog control panels.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003eWe maintain ready-to-ship inventory of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-252\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto minimize your facility's downtime.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 business days after payment confirmation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExpress delivery via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-sealed anti-static packaging with original documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Does the 9907-252 support isochronous load sharing?\u003c\/p\u003e\n\u003cp\u003eA1: Yes, when connected via the load sharing lines to other compatible Woodward modules, it maintains a constant frequency (Zero Droop) across the entire load range.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use this module with non-Woodward governors?\u003c\/p\u003e\n\u003cp\u003eA2: While optimized for Woodward systems, this module can interface with any electronic governor that accepts a ±Vdc offset signal for speed bias control.\u003c\/p\u003e\n\u003cp\u003eQ3: What happens if the load sharing line is interrupted?\u003c\/p\u003e\n\u003cp\u003eA3: The module is designed to fail-safe into a pre-configured droop mode, ensuring the generator remains online and stable, though it will no longer share the load proportionally with other units.\u003c\/p\u003e\n\u003cp\u003eQ4: Is it necessary to use shielded cable for the CT inputs?\u003c\/p\u003e\n\u003cp\u003eA4: Absolutely. High-current environments generate significant EMI. Shielded, twisted-pair cabling is mandatory to ensure the module receives a clean current signal for accurate KW calculation.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":45922990686381,"sku":"9907-252","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/9907-252-1.jpg?v=1776651955","url":"https:\/\/www.maxwellplc.com\/products\/woodward-9907-252-load-sharing-module-24vdc-industrial-control-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}