{"product_id":"woodward-8406-113-egcp-3-load-sharing-control-module-ls-engine-generator-package","title":"Woodward 8406-113 EGCP-3 Load Sharing Control Module | LS Engine Generator Package","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 8406-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the intelligent core of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEGCP-3 (Engine Generator Control Package)\u003c\/strong\u003e, specifically optimized for high-demand Load Sharing (LS) applications. This microprocessor-based controller manages the complex synchronization and proportional load distribution across multiple engine-generator sets in parallel. By continuously monitoring grid parameters and engine performance, the 8406-113 ensures seamless power transitions and prevents generator instability in mission-critical environments such as hospitals, data centers, and remote industrial plants. Its integrated dual-backlit LCD interface provides real-time visibility into engine status and electrical variables, making it an essential component for facilities requiring automated, reliable power management and protection.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThe EGCP-3 LS hardware architecture emphasizes versatile communication and precision control logic. This module features three dedicated serial ports that facilitate high-speed data exchange via the ServLink protocol, allowing for remote monitoring and configuration through Woodward’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWatch Window\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware.\u003c\/p\u003e\n\u003cp\u003ePrecision speed bias outputs, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA, 0–5 V, and PWM\u003c\/strong\u003e, ensure the 8406-113 can interface with nearly any electronic governor on the market. The unit’s firmware includes a sophisticated \"First Time Startup Menu,\" which locks in critical engine parameters to prevent accidental modification during active operation—a vital safety feature for preventing catastrophic engine overspeed or synchronization errors. Furthermore, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEMA 4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated front panel ensures the unit withstands moisture and dust infiltration when mounted in standard industrial enclosures.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8406-113 (EGCP-3 LS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18-32 V DC (24 V DC Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e282 mm H x 359 mm W x 135 mm D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.3 kg (9.5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30°C to +80 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeed Bias Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA, 0–5 V, PWM, or ±3 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Serial Ports (ServLink Compatible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEMA 4 Front Panel (When installed correctly)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Backlit LCD (8-line status \/ 4-line config)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cp\u003eSuccessful commissioning of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 8406-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estarts with the physical mounting. Ensure the panel cutout matches the 282x359mm profile precisely to maintain the NEMA 4 seal integrity. For electrical integration, use shielded, twisted-pair cabling for all speed bias and load-sharing lines to eliminate electromagnetic interference (EMI) from the alternator.\u003c\/p\u003e\n\u003cp\u003eDuring the initial power-up, engineers must access the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFirst Time Startup Menu\u003c\/strong\u003e. Carefully verify the generator's PT (Potential Transformer) and CT (Current Transformer) ratios before the engine starts, as the controller locks these values once it detects active RPM to maintain system safety. If remote configuration is required, connect the ServLink serial link to a PC running Watch Window software, ensuring the baud rate matches the 8406-113 serial port settings for reliable data transfer.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8406-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers unparalleled durability in extreme thermal environments, maintaining precise load regulation from -20°C to +70°C. Its ability to provide multiple output formats (PWM, analog, and voltage) makes it a \"universal\" solution for legacy engine retrofits and modern system upgrades alike. The dual LCD screen setup significantly reduces troubleshooting time by allowing technicians to view alarm logs on one screen while monitoring live engine data on the other—a critical advantage during emergency power restoration scenarios.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003eWe maintain high-quality stock of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 8406-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto support your urgent maintenance needs.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 business days upon payment completion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCourier Partners:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGlobal express shipping via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBrand New, original factory packaging with sealed protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I change the engine configuration while the generator is running?\u003c\/p\u003e\n\u003cp\u003eA1: No. For safety reasons, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8406-113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elocks the First Time Startup Menu once the engine is in operation. Configuration changes must be made with the engine at a standstill.\u003c\/p\u003e\n\u003cp\u003eQ2: What is the benefit of the NEMA 4 rating for this module?\u003c\/p\u003e\n\u003cp\u003eA2: The NEMA 4 rating ensures the front faceplate is protected against windblown dust, rain, and splashing water, making it suitable for outdoor-rated control cabinets in harsh climates.\u003c\/p\u003e\n\u003cp\u003eQ3: Does this unit support remote monitoring?\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the three serial ports allow connection via ServLink to Woodward’s Watch Window software, providing comprehensive remote diagnostics and data logging.\u003c\/p\u003e\n\u003cp\u003eQ4: Is the 8406-113 compatible with older analog governors?\u003c\/p\u003e\n\u003cp\u003eA4: Yes, the module provides a ±3 V output specifically designed to bias older analog speed controls for proportional load sharing.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":45923185393837,"sku":"8406-113","price":2599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/8406-113_1.jpg?v=1776655735","url":"https:\/\/www.maxwellplc.com\/products\/woodward-8406-113-egcp-3-load-sharing-control-module-ls-engine-generator-package","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}