{"product_id":"ur-7cv-general-multilin-ur7cv-communications-module-ur-7cv","title":"UR 7CV General Multilin UR7CV Communications Module UR-7CV","description":"\u003ch3 data-start=\"89\" data-end=\"109\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"110\" data-end=\"512\"\u003eThe \u003cstrong data-start=\"114\" data-end=\"135\"\u003eGE Multilin UR7CV\u003c\/strong\u003e is a \u003cstrong data-start=\"141\" data-end=\"174\"\u003eplug-in communications module\u003c\/strong\u003e for the \u003cstrong data-start=\"183\" data-end=\"225\"\u003eMultilin UR (Universal Relay) platform\u003c\/strong\u003e, used to expand relay connectivity for protection, control, and monitoring systems. Installed in compatible UR relays, the module provides an additional communications interface to support \u003cstrong data-start=\"415\" data-end=\"447\"\u003erelay-to-relay data exchange\u003c\/strong\u003e and \u003cstrong data-start=\"452\" data-end=\"511\"\u003eintegration with substation\/industrial control networks\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"514\" data-end=\"868\"\u003eUR communication modules like the UR7CV are commonly applied to improve system maintainability by enabling centralized status collection, event reporting, and remote access to relay information through the site’s communication architecture. Final interface type and supported services depend on the relay configuration and installed communication option.\u003c\/p\u003e\n\u003ch3 data-start=\"870\" data-end=\"893\"\u003eHardware Parameters\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"894\" data-end=\"1299\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"894\" data-end=\"918\"\u003e\n\u003ctr data-start=\"894\" data-end=\"918\"\u003e\n\u003cth data-start=\"894\" data-end=\"901\" data-col-size=\"sm\"\u003eItem\u003c\/th\u003e\n\u003cth data-start=\"901\" data-end=\"918\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"929\" data-end=\"1299\"\u003e\n\u003ctr data-start=\"929\" data-end=\"946\"\u003e\n\u003ctd data-start=\"929\" data-end=\"937\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"937\" data-end=\"946\"\u003eUR7CV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"947\" data-end=\"987\"\u003e\n\u003ctd data-start=\"947\" data-end=\"962\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e\n\u003ctd data-start=\"962\" data-end=\"987\" data-col-size=\"sm\"\u003eCommunications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"988\" data-end=\"1027\"\u003e\n\u003ctd data-start=\"988\" data-end=\"1005\" data-col-size=\"sm\"\u003eProduct family\u003c\/td\u003e\n\u003ctd data-start=\"1005\" data-end=\"1027\" data-col-size=\"sm\"\u003eMultilin UR Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1028\" data-end=\"1079\"\u003e\n\u003ctd data-start=\"1028\" data-end=\"1037\" data-col-size=\"sm\"\u003eSystem\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1037\" data-end=\"1079\"\u003ePLC \/ Protection \u0026amp; Control Integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1080\" data-end=\"1105\"\u003e\n\u003ctd data-start=\"1080\" data-end=\"1092\" data-col-size=\"sm\"\u003eCondition\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1092\" data-end=\"1105\"\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1106\" data-end=\"1133\"\u003e\n\u003ctd data-start=\"1106\" data-end=\"1121\" data-col-size=\"sm\"\u003eAvailability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1121\" data-end=\"1133\"\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1134\" data-end=\"1154\"\u003e\n\u003ctd data-start=\"1134\" data-end=\"1143\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1143\" data-end=\"1154\"\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1155\" data-end=\"1190\"\u003e\n\u003ctd data-start=\"1155\" data-end=\"1168\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"1168\" data-end=\"1190\" data-col-size=\"sm\"\u003e16.3 × 4.2 × 21 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1191\" data-end=\"1218\"\u003e\n\u003ctd data-start=\"1191\" data-end=\"1211\" data-col-size=\"sm\"\u003eCountry of origin\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1211\" data-end=\"1218\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1219\" data-end=\"1243\"\u003e\n\u003ctd data-start=\"1219\" data-end=\"1229\" data-col-size=\"sm\"\u003eHS Code\u003c\/td\u003e\n\u003ctd data-start=\"1229\" data-end=\"1243\" data-col-size=\"sm\"\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1244\" data-end=\"1287\"\u003e\n\u003ctd data-start=\"1244\" data-end=\"1263\" data-col-size=\"sm\"\u003eLifecycle status\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1263\" data-end=\"1287\"\u003eActive (per listing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1288\" data-end=\"1299\"\u003e\n\u003ctd data-start=\"1288\" data-end=\"1294\" data-col-size=\"sm\"\u003eMOQ\u003c\/td\u003e\n\u003ctd data-start=\"1294\" data-end=\"1299\" data-col-size=\"sm\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"1301\" data-end=\"1334\"\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1335\" data-end=\"1917\"\u003e\n\u003cli data-start=\"1335\" data-end=\"1427\"\u003e\n\u003cp data-start=\"1337\" data-end=\"1427\"\u003e\u003cstrong data-start=\"1337\" data-end=\"1381\"\u003eUR-series add-on communications hardware\u003c\/strong\u003e for protection relay connectivity expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1428\" data-end=\"1553\"\u003e\n\u003cp data-start=\"1430\" data-end=\"1553\"\u003e\u003cstrong data-start=\"1430\" data-end=\"1479\"\u003eDesigned for cabinet\/relay panel environments\u003c\/strong\u003e, supporting stable operation in utility and industrial electrical rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1554\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1556\" data-end=\"1685\"\u003e\u003cstrong data-start=\"1556\" data-end=\"1596\"\u003eSupports remote monitoring workflows\u003c\/strong\u003e by enabling networked access to relay data and status (system configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1795\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1795\"\u003e\u003cstrong data-start=\"1688\" data-end=\"1723\"\u003eService-friendly modular format\u003c\/strong\u003e for maintenance replacement without redesigning the base relay wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1796\" data-end=\"1917\"\u003e\n\u003cp data-start=\"1798\" data-end=\"1917\"\u003e\u003cstrong data-start=\"1798\" data-end=\"1840\"\u003eConfiguration via UR engineering tools\u003c\/strong\u003e typically managed through EnerVista software suite (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1919\" data-end=\"1946\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul data-start=\"1947\" data-end=\"2421\"\u003e\n\u003cli data-start=\"1947\" data-end=\"2065\"\u003e\n\u003cp data-start=\"1949\" data-end=\"2065\"\u003e\u003cstrong data-start=\"1949\" data-end=\"1974\"\u003eSubstation automation\u003c\/strong\u003e where UR relays require additional communication capability for monitoring and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2180\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2180\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2119\"\u003eFeeder, transformer, and line protection panels\u003c\/strong\u003e using UR relays and external communications infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2181\" data-end=\"2290\"\u003e\n\u003cp data-start=\"2183\" data-end=\"2290\"\u003e\u003cstrong data-start=\"2183\" data-end=\"2216\"\u003eIndustrial power distribution\u003c\/strong\u003e in plants requiring relay visibility from SCADA or control room systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2291\" data-end=\"2421\"\u003e\n\u003cp data-start=\"2293\" data-end=\"2421\"\u003e\u003cstrong data-start=\"2293\" data-end=\"2314\"\u003eRetrofit projects\u003c\/strong\u003e adding communications capability to existing UR relay installations without replacing the relay platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519070789805,"sku":"UR7CV","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ur7cv-multilin-comms-module-5qreebdre5l.jpg?v=1766986206","url":"https:\/\/www.maxwellplc.com\/products\/ur-7cv-general-multilin-ur7cv-communications-module-ur-7cv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}