{"product_id":"ur-6dv-ge-multilin-ur6dv-digital-i-o-module-ur-6dv","title":"UR 6DV GE Multilin UR6DV Digital I\/O Module UR-6DV","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR6DV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital input\/output expansion module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Multilin UR relay platform. It is used to add discrete status monitoring and control points to compatible UR-series relays, allowing the relay to interface with external equipment such as breaker auxiliaries, interlocks, alarms, and command circuits.\u003c\/p\u003e\n\u003cp\u003eIn protection and control panels, this module supports cabinet-level integration by providing additional discrete I\/O capacity without redesigning the relay system. The UR6DV is typically selected for like-for-like replacement or for expanding existing UR relay installations where additional points are required.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR6DV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003eMultilin UR Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eDCS \/ Protection \u0026amp; Control Integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.2 × 12.2 × 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscontinued status\u003c\/td\u003e\n\u003ctd\u003eActive (per listing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOQ\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiscrete signal expansion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto increase relay-based monitoring and control points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUR-series relay compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor straightforward integration into existing protection panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet-ready modular form factor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupporting service replacement and upgrade work with minimal downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable digital acquisition and output control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field contacts and command circuits (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration through UR settings tools\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically managed using EnerVista workflows (site dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubstation automation and switchgear panels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor breaker status, trip\/close permissives, and alarm contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial power distribution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere UR relays interface with MCCs, contactors, and auxiliary interlocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection and control retrofits\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring additional discrete points without changing the base relay platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance replacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto restore I\/O functionality while preserving existing wiring and relay configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519070691501,"sku":"UR6DV","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ur6dv-digital-i-o-module-wti02kbmyxq.jpg?v=1766986204","url":"https:\/\/www.maxwellplc.com\/products\/ur-6dv-ge-multilin-ur6dv-digital-i-o-module-ur-6dv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}