{"product_id":"triconex-communication-module-cm2201-7400206-100-trident-series","title":"Triconex Communication Module CM2201 7400206-100 Trident Series","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Triconex CM2201 (Part Number 7400206-100) is a high-performance Communication Module designed specifically for the Trident Safety System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eActing as the primary data exchange hub,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module bridges the gap between the internal safety bus and external plant networks.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt ensures that critical diagnostic information and process variables are transmitted with high integrity to the supervisory layer.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy offloading communication overhead from the main safety processors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe CM2201 maintains the deterministic performance required for SIL 3 safety applications while providing extensive connectivity to Distributed Control Systems (DCS) and Human-Machine Interfaces (HMI).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Architecture and Interface Capabilities\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe CM2201 is engineered for versatility and massive scalability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing it to act as a high-density gateway within the Trident architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eI\/O Point Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCapable of managing and routing data for up to 2,\u003c\/span\u003e\u003cspan class=\"\"\u003e048 I\/O points across the safety system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConnectivity Standards:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNative support for industry-standard protocols including Modbus (Master\/Slave),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOPC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Ethernet\/IP.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFacilitates seamless \"Ethernet Router\" services to link safety sub-nets with plant-wide information systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrates into the Trident fault-tolerant framework to ensure communication persists during hardware malfunctions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtocol Versatility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSimplified integration with third-party PLC platforms and monitoring equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetric \/ Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCM2201\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrder Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7400206-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23 x 24.7 x 4.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturing Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrident Safety Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eIndustrial Networking Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe CM2201 7400206-100 is deployed in safety-critical sectors where the transparency of the safety system to the operator is vital for risk mitigation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDistributed Control System Integration\u003c\/strong\u003e\u003cspan class=\"\"\u003eIn large-scale refineries,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe CM2201 allows the Trident safety system to feed real-time status data to a central DCS.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis facilitates unified alarm management and synchronized time-stamping for sequence-of-events (SOE) recording.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRemote Supervisory Monitoring\u003c\/strong\u003e\u003cspan class=\"\"\u003eFor offshore platforms or remote pipeline stations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module provides the Ethernet-based gateway needed for satellite or long-range wireless telemetry.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis ensures that safety health metrics are visible to engineers at centralized operations centers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEmergency Response Coordination\u003c\/strong\u003e\u003cspan class=\"\"\u003eBy utilizing Modbus or Ethernet\/IP,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe CM2201 can trigger coordinated protective actions across multiple vendors' equipment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as shutting down downstream pumps or isolating power breakers when a safety trip is initiated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFacility Upgrades and Scalability\u003c\/strong\u003e\u003cspan class=\"\"\u003eAs industrial processes grow,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe high I\/O capacity of the CM2201 allows for the addition of new Trident modules without requiring a complete redesign of the communication architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering a cost-effective path for safety system expansion.\u003c\/span\u003e\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":45519044804781,"sku":"7400206-100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/triconex-cm2201-7400206-100-communication-module-gnhd2d4yr5q.jpg?v=1766985700","url":"https:\/\/www.maxwellplc.com\/products\/triconex-communication-module-cm2201-7400206-100-trident-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}