{"product_id":"tm2dockn-schneider-electric-analog-i-o-module-modicon-m218","title":"TM2DOCKN Schneider Electric Analog I\/O module Modicon M218","description":"\u003cp\u003eConfigured for analogue signal processing in Modicon M218 automation platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric TM2DOCKN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eTM2DOCKN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalogue I\/O module) provides direct physical\/electrical execution for system expansion across modular I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eSystem Compatibility and Integration\u003c\/h3\u003e\n\u003cp\u003eThe TM2DOCKN is a dedicated hardware component for extending I\/O capabilities within the Modicon M218 system ecosystem. The module design maintains architectural consistency with Advantys OTB and Twido series controllers, facilitating seamless integration in distributed or local I\/O configurations. It is engineered to perform as an interface for signal acquisition and output management, ensuring compliance with the operational requirements of the M218 backplane bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTM2DOCKN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to production site labeling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.110 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 cm x 8.6 cm x 12.9 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to controller system specs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to M218 system manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalogue I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSchneider Electric Deterministic Control Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe M218 platform utilizes specific backplane bus communication velocity parameters to ensure data consistency across connected expansion modules. The TM2DOCKN is validated for use within this deterministic network, supporting I\/O density scaling. The module ensures firmware flash compatibility with the M218 controller, allowing for precise control loop execution and minimizing latency during process signal transmission.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x TM2DOCKN Analogue I\/O module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product documentation set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Field Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install the module on a standard 35 mm DIN-rail. Ensure the locking latch is engaged to secure the mechanical connection and ensure the continuity of the grounding path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Routing: Keep analogue signal cabling separated from high-voltage power lines to prevent electromagnetic induction. Use shielded cabling for all analogue input\/output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain a low-impedance connection to the chassis earth ground to ensure the effectiveness of internal filtering circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: Install within an enclosure rated to at least IP20, ensuring that relative humidity and ambient temperature are maintained within the system's specified operational range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the TM2DOCKN hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No, this module does not support hot-swapping. The power to the M218 expansion rack must be disconnected before the module is installed or removed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this module support Advantys OTB compatibility?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the TM2DOCKN is designed for range compatibility with both Advantys OTB and Twido series components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary function of this module?\u003c\/p\u003e\n\u003cp\u003eA: It serves as an analogue I\/O expansion module specifically designed for the Modicon M218 logic controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this module require an external power supply?\u003c\/p\u003e\n\u003cp\u003eA: Power requirements are handled through the M218 backplane; however, verify specific loading requirements in the controller hardware manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the module secured to the DIN-rail?\u003c\/p\u003e\n\u003cp\u003eA: The unit features an integrated locking latch designed for mounting on standard 35 mm symmetric DIN-rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the weight of the module?\u003c\/p\u003e\n\u003cp\u003eA: The module has a net weight of 0.110 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the module firmware upgradable?\u003c\/p\u003e\n\u003cp\u003eA: Firmware updates are managed via the host M218 controller; ensure the controller's firmware is compatible with the expansion module's requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are there specific shielding requirements?\u003c\/p\u003e\n\u003cp\u003eA: Yes, all analogue signals should be transmitted via shielded, twisted-pair cables to ensure signal integrity and reduce common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46475287658669,"sku":"TM2DOCKN","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/TM2DOCKN_4.jpg?v=1782808910","url":"https:\/\/www.maxwellplc.com\/products\/tm2dockn-schneider-electric-analog-i-o-module-modicon-m218","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}