{"product_id":"tk811v015-3bsc950107r1-abb-fiber-optic-cable-advant-ocs","title":"TK811V015 3BSC950107R1 ABB Fiber Optic Cable Advant OCS","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB TK811V015 3BSC950107R1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTK811V015\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFiber Optic Cable, operates as a dedicated hardware component for facilitating signal transmission between AC 800M controllers within Advant OCS and System 800xA network platforms.\u003c\/p\u003e\n\u003ch3\u003ePhysical Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTK811V015\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3BSC950107R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlastic Optical Fiber (POF) Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTK811V015 (3BSC950107R1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 x 20.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Passive component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWavelength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Loss\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 3.5 dB\/km\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBend Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 mm (Static)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Integration\u003c\/h3\u003e\n\u003cp\u003eThe TK811V015 supports backplane bus communication velocity requirements by providing high-integrity, EMI-immune pathways for distributed controller segments. The cable assembly ensures deterministic data exchange, maintaining compatibility with firmware flash procedures across the control network. Its design supports I\/O density scaling by allowing flexible routing of fiber links in high-density automation subracks, preventing signal corruption in environments with high electromagnetic noise.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) TK811V015 Optical Fiber Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePre-configured crossover interface connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical compliance and safety documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHandling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAvoid excessive pulling force or sharp bends; maintain the 15 mm static bend radius to prevent internal fiber damage or light leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRouting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute cables away from high-voltage power conduits to ensure maximum physical protection of the orange outer cladding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInsert connectors firmly into the optical ports of the AC 800M hardware; ensure the transmit-to-receive (crossover) logic matches the port orientation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure installation remains within the specified temperature range of -25 deg C to +60 deg C for optimal transmission performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable suitable for long-distance communication?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable is designed for intra-cabinet or localized controller-to-controller links within DCS systems; verify the attenuation budget for extended distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it provide electrical isolation?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the use of plastic optical fiber ensures total galvanic isolation, eliminating ground loops and EMI\/RFI interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable fire-retardant?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the outer cladding is compliant with IEC 60332-1 flame-retardant standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be field-terminated?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePre-configured factory terminations are recommended to maintain the specified optical numerical aperture and signal loss characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the crossover design?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal configuration ensures proper transmit-to-receive mapping between connected network components without external adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes light color affect performance?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 650 nm visible red light is standard for POF systems; ensure the transceiver hardware is calibrated for this wavelength.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs it UV-resistant?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the outer orange cladding is formulated to resist degradation from UV light exposure in industrial installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the static bend radius?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe minimum static bend radius is 15 mm; do not exceed this limit during cabinet routing to avoid permanent optical signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231168684205,"sku":"3BSC950107R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-tk811v015-3bsc950107r1-fiber-optic-cable-u2ph11gbzbu_b4bb76fc-8345-443e-b87d-eafb029c02c7.jpg?v=1762942243","url":"https:\/\/www.maxwellplc.com\/products\/tk811v015-3bsc950107r1-abb-fiber-optic-cable-advant-ocs","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}