{"product_id":"tk801v006-3bsc950089r2-abb-modulebus-extension-cable-advant-ocs-800xa","title":"TK801V006 3BSC950089R2 ABB Modulebus Extension Cable Advant OCS\/800xA","description":"\u003cp\u003eConfigured for high-speed signal extension across distributed node racks in automation frameworks, the \u003cstrong\u003eABB TK801V006 3BSC950089R2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTK801V006\u003c\/strong\u003e Modulebus Extension Cable, provides direct physical and electrical execution by linking ModuleBus segments between separate DIN-rail mount assemblies.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown \u0026amp; Model Configuration\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Level\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eIdentifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003ctd\u003eManufacturer entity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAdvant OCS \/ 800xA\u003c\/td\u003e\n\u003ctd\u003eIndustrial control platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTK801V006\u003c\/td\u003e\n\u003ctd\u003eModulebus Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSC950089R2\u003c\/td\u003e\n\u003ctd\u003eFactory catalog reference ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK801V006 3BSC950089R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 cm x 2.5 cm x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive shielded interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.6 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate Support\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Network Communication Parameters\u003c\/h3\u003e\n\u003cp\u003eThe hardware utilizes backplane bus communication velocity licences to maintain deterministic packet transfers across extended ModuleBus segments. I\/O density scaling capabilities allow operators to bridge multiple DIN rails without violating bus timing constraints or update intervals. Firmware flash compatibility ensures that low-level communication protocol stacks remain synchronized across distributed node architectures during high-speed process operations.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB TK801V006 Modulebus Extension Cable (Part Number: 3BSC950089R2)\u003c\/li\u003e\n\u003cli\u003e1 x D-Sub 25 Male\/Female Connector Set\u003c\/li\u003e\n\u003cli\u003e1 x Technical Compliance Documentation Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation \u0026amp; Grounding Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the D-Sub 25 male and female connectors carefully with the corresponding ports on the bus extension modules to prevent bent pins.\u003c\/li\u003e\n\u003cli\u003eSecure the locking screws on both connector ends to maintain structural stability against continuous industrial vibration.\u003c\/li\u003e\n\u003cli\u003eEnsure the outer shielding braid maintains continuous low-impedance contact with the cabinet grounding plane to suppress noise.\u003c\/li\u003e\n\u003cli\u003eKeep the cable run physically separated from high-voltage power lines to eliminate electromagnetic interference on the communication bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the primary operational function of this extension cable within the control system?\u003c\/li\u003e\n\u003cli\u003eA: It connects bus extension units to bridge electrical ModuleBus lines across multiple DIN rails.\u003c\/li\u003e\n\u003cli\u003eQ: What is the exact physical length of the cable assembly?\u003c\/li\u003e\n\u003cli\u003eA: The assembly features a fixed operating length of 0.6 meters.\u003c\/li\u003e\n\u003cli\u003eQ: What maximum data transfer rate is supported by the cable?\u003c\/li\u003e\n\u003cli\u003eA: The hardware supports reliable data transmission speeds up to 10 Mbps across the bus extension.\u003c\/li\u003e\n\u003cli\u003eQ: Does this passive cable require an external power supply connection?\u003c\/li\u003e\n\u003cli\u003eA: No, it operates entirely as a shielded passive interconnect without active power requirements.\u003c\/li\u003e\n\u003cli\u003eQ: What operational temperature range is specified for the assembly?\u003c\/li\u003e\n\u003cli\u003eA: The hardware functions reliably within an ambient operating temperature range of -20 deg C to +70 deg C.\u003c\/li\u003e\n\u003cli\u003eQ: How does proper shield grounding affect communication stability?\u003c\/li\u003e\n\u003cli\u003eA: Comprehensive shielding shunts high-frequency electromagnetic interference away from sensitive data conductors.\u003c\/li\u003e\n\u003cli\u003eQ: Which specific bus modules work in conjunction with this cable?\u003c\/li\u003e\n\u003cli\u003eA: It is utilized alongside TB805\/TB845 and TB806\/TB846 interface modules to extend the electrical ModuleBus.\u003c\/li\u003e\n\u003cli\u003eQ: What precautions should be taken during physical routing?\u003c\/li\u003e\n\u003cli\u003eA: Avoid sharp bends and severe mechanical tension to protect the internal wiring and connector pins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021144838317,"sku":"3BSC950089R2","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/TK801V006_13.jpg?v=1783416642","url":"https:\/\/www.maxwellplc.com\/products\/tk801v006-3bsc950089r2-abb-modulebus-extension-cable-advant-ocs-800xa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}