{"product_id":"tc-ccr013-honeywell-controlnet-redundant-network-interface-module","title":"TC-CCR013 Honeywell ControlNet Redundant Network Interface Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell TC-CCR013 is a high-availability communication bridge designed for ControlNet architectures within industrial Distributed Control Systems (DCS).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for high-uptime environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module provides the critical link between redundant network media and the control processor.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is specifically built to manage failover scenarios by supporting dual-redundant firmware and physical media paths,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that a single cable break or firmware glitch does not interrupt process execution.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs a core component in the Honeywell Experion and ControlLogix integration landscape,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TC-CCR013 facilitates deterministic data exchange,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it indispensable for time-sensitive control loops where synchronization is mandatory.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eEngineering Specifications and Hardware Interface\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Identification:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTC-CCR013 (Spare Part:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e97197971A01)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Protocol:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eControlNet (Redundant Media Support)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage Requirement:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRegulated Output Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC @ 5A Maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Tolerance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +50°C (-4°F to 122°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHumidity Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Mass:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 kg (Net) \/ 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 kg (Shipping)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Form Factor:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 x 16.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eShipping Volume:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e7 x 14 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eManufactured in the USA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eStrategic Industrial Utility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe TC-CCR013 is strategically deployed in safety-critical and high-production industries such as upstream oil and gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epharmaceutical manufacturing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand chemical processing.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts primary role is to eliminate single points of failure within the communication layer of a Distributed Control System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing redundant coaxial or fiber media,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TC-CCR013 ensures that the central controller maintains constant visibility of remote I\/O racks and field instrumentation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is frequently found in \"non-stop\" process environments where unplanned downtime results in significant financial loss or safety risks.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts compact design allows for easy integration into existing ControlLogix-style backplanes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting both new installations and legacy system expansions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: What exactly does \"Redundant Net Interface\" mean for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt means the module has two separate ports for network cables (Path A and Path B).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf one cable is damaged or the signal is lost,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TC-CCR013 instantly switches to the secondary path without dropping any data packets or stopping the control process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Is the TC-CCR013 compatible with standard ControlLogix racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TC-CCR013 is designed to fit seamlessly into the ControlLogix\/Honeywell hardware architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt shares the same physical dimensions and backplane interface as other standard modules in that series.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Does this module require specialized configuration software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module is typically configured through Honeywell’s Experion PKS or ControlNet configuration tools.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt supports standard ControlNet scheduling to ensure that all time-critical data is transmitted at specific intervals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Can this module operate in unheated outdoor cabinets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe TC-CCR013 is rated down to -20°C.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIn extreme northern climates where temperatures may drop further, a cabinet heater is recommended to maintain the operational integrity of the electronic components and prevent condensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the 5A maximum output current?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This indicates the module's capability to provide regulated power to downstream components on the same bus or interface. This robust power rating ensures that even heavily loaded racks have a stable 24V supply for logic processing.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518944338093,"sku":"TC-CCR013","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-tc-ccr013-redundant-net-interface-module-gwruwbqz3u4.jpg?v=1766982540","url":"https:\/\/www.maxwellplc.com\/products\/tc-ccr013-honeywell-controlnet-redundant-network-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}