{"product_id":"tb825-3bse036634r1-abb-s800-i-o-optical-media-converter","title":"TB825 3BSE036634R1 ABB S800 I\/O Optical Media Converter","description":"\u003cp\u003eConfigured for physical-layer signal translation between plastic\/HCS optical fibers and glass optical fibers in S800 I\/O systems, the \u003cstrong\u003eABB TB825 3BSE036634R1\u003c\/strong\u003e (\u003cstrong\u003eTB825\u003c\/strong\u003e Optical Media Converter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Subsystem Variant\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTB825\u003c\/strong\u003e: Specific hardware designator for S800L mechanics ModuleBus optical media converter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3BSE036634R1\u003c\/strong\u003e: Orderable commercial part identifier for module replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus Slave\u003c\/strong\u003e: Operates strictly as a slave node interface on optical media segments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTB825 3BSE036634R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.2 x 5.1 x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e96 mA (typical at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModuleBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eSlave, Non-redundant line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Optic Media\u003c\/td\u003e\n\u003ctd\u003ePlastic\/HCS opto fiber to Glass optical fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Connectors\u003c\/td\u003e\n\u003ctd\u003eVersatile Link (Plastic\/HCS) to ST (Glass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus Velocity \u0026amp; Scalability\u003c\/h3\u003e\n\u003cp\u003eThe unit maintains backplane bus communication velocity across distributed fiber optic clusters, converting local versatile-link plastic\/HCS cabling into long-distance glass ST multi-mode paths. This execution ensures stable sequence handling during high-density I\/O density scaling up to seven fiber-connected ModuleBus clusters. Hardware firmware flash compatibility allows transparent protocol translation without altering controller frame structures.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB TB825 3BSE036634R1 Optical Media Converter\u003c\/li\u003e\n\u003cli\u003e1 x Mechanical DIN-rail installation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Assembly \u0026amp; Fiber Termination Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely on a standard 35 mm DIN rail within a protective enclosure.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC auxiliary power conductors ensuring clean voltage delivery at 96 mA current levels.\u003c\/li\u003e\n\u003cli\u003eTerminate plastic or HCS fibers into the Versatile Link optical ports using appropriate bend-radius guides.\u003c\/li\u003e\n\u003cli\u003eAttach multi-mode glass fiber cables equipped with standard ST connectors to the glass interface ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat optical connector types are supported on the TB825 unit?\u003c\/p\u003e\n\u003cp\u003eThe module features Versatile Link connectors for plastic\/HCS fibers and ST connectors for multi-mode glass fibers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the converter require software configuration or driver setup?\u003c\/p\u003e\n\u003cp\u003eNo, the unit operates as a physical-layer protocol converter without requiring software configuration or driver installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the typical operating power draw for this media converter?\u003c\/p\u003e\n\u003cp\u003eThe hardware operates on a standard 24 VDC input with a typical current consumption of 96 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat hazardous area installation approvals apply to the TB825?\u003c\/p\u003e\n\u003cp\u003eThe module holds certifications for C1 Div 2 cULus, C1 Zone 2 cULus, and ATEX Zone 2 hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs line redundancy supported on a single TB825 converter card?\u003c\/p\u003e\n\u003cp\u003eNo, the TB825 hardware architecture is engineered specifically for non-redundant ModuleBus optical line execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature range is permitted for certified operation?\u003c\/p\u003e\n\u003cp\u003eOperating ambient temperatures cover 0 to +55 deg C, with specific agency approvals issued for +5 to +55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many I\/O clusters can be interconnected over the fiber network?\u003c\/p\u003e\n\u003cp\u003eThe fiber optic ModuleBus architecture supports interconnecting up to seven distributed I\/O clusters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat marine classification societies have certified this module?\u003c\/p\u003e\n\u003cp\u003eThe converter is certified for marine installations by ABS, Bureau Veritas (BV), DNV-GL, and Lloyd's Register (LR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021126062253,"sku":"TB825 3BSE036634R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_tb825_3bse036634r1_1.jpg?v=1787241108","url":"https:\/\/www.maxwellplc.com\/products\/tb825-3bse036634r1-abb-s800-i-o-optical-media-converter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}