{"product_id":"tb810-3bse008560r1-abb-modulebus-optical-port-s800-i-o","title":"TB810 3BSE008560R1 ABB Modulebus Optical Port S800 I\/O","description":"\u003cp\u003eConfigured for high-speed signal transmission in S800 I\/O distributed control network platforms, the \u003cstrong\u003eABB TB810\u003c\/strong\u003e (\u003cstrong\u003e3BSE008560R1\u003c\/strong\u003e Modulebus Optical Port) provides direct physical electrical execution for fiber optic-based communication between controller and I\/O clusters.\u003c\/p\u003e\n\u003ch3\u003eModel Identification and Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model: TB810\u003c\/li\u003e\n\u003cli\u003ePart Number: 3BSE008560R1\u003c\/li\u003e\n\u003cli\u003eCommunication Type: Fiber Optic ModuleBus\u003c\/li\u003e\n\u003cli\u003eSeries: S800 I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTB810 (3BSE008560R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2 x 5.2 x 4.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Transmission Distance\u003c\/td\u003e\n\u003ctd\u003e2 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Interface\u003c\/td\u003e\n\u003ctd\u003eSingle-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe TB810 facilitates I\/O density scaling by bridging the local Modulebus to remote segments via optical fiber. This interface supports deterministic network behavior required for high-speed process control. The module is engineered to maintain backplane bus communication velocity across expanded distances, ensuring synchronization across up to 128 connected I\/O nodes. Firmware flash compatibility is managed via the host controller, ensuring persistent communication alignment within the control topology.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 unit: TB810 Modulebus Optical Port\u003c\/li\u003e\n\u003cli\u003e1 set: Dust protection caps for optical transceivers\u003c\/li\u003e\n\u003cli\u003e1 unit: Installation instruction leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Optical Link Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePhysical Mounting:\n\u003cul\u003e\n\u003cli\u003eAlign the port module with the dedicated Modulebus interface on the S800 hardware carrier.\u003c\/li\u003e\n\u003cli\u003eEnsure the optical transceivers are clean and free of debris prior to cable insertion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptical Link Standards:\n\u003cul\u003e\n\u003cli\u003eSelect fiber optic cable type based on the 10 Mbps requirement; Hard Clad Silica (HCS) is mandatory for this data rate.\u003c\/li\u003e\n\u003cli\u003eAdhere to minimum bend radius specifications for the chosen fiber medium to prevent signal attenuation.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 2 km maximum distance threshold to ensure signal integrity and receiver sensitivity levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the TB810 be used with Plastic Optical Fiber (POF)?\u003c\/p\u003e\n\u003cp\u003eA: POF cables are restricted to systems operating at 5 Mbps; for the 10 Mbps performance of the TB810, HCS or appropriate single-mode cabling is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the port provide galvanic isolation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the fiber optic medium inherently provides total galvanic isolation between the controller and the I\/O cluster, eliminating ground loop risks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the TB810 hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is restricted; isolate the 24 VDC power supply before installing or removing the optical port from the Modulebus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum number of I\/O modules supported?\u003c\/p\u003e\n\u003cp\u003eA: The interface is capable of supporting up to 128 S800 I\/O modules when configured within the system controller's addressing limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the TB810 react to electromagnetic noise?\u003c\/p\u003e\n\u003cp\u003eA: Due to the nature of fiber optics, the unit is immune to electromagnetic (EMI) and radio frequency (RFI) interference, ensuring data integrity in high-noise environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are the optical ports orientation-sensitive?\u003c\/p\u003e\n\u003cp\u003eA: Yes, maintain correct polarity (transmit to receive) when connecting fiber optic cables between the master and remote ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the TB810 require specialized configuration software?\u003c\/p\u003e\n\u003cp\u003eA: System-level configuration is managed through the controller software; the port itself is a physical layer device requiring no independent firmware setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What voltage source is required for operation?\u003c\/p\u003e\n\u003cp\u003eA: The device operates on standard 24 VDC supplied via the S800 I\/O backplane or external auxiliary power terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021155389613,"sku":"3BSE008560R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/TB810_3.jpg?v=1780391730","url":"https:\/\/www.maxwellplc.com\/products\/tb810-3bse008560r1-abb-modulebus-optical-port-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}