{"product_id":"t9832-ics-triplex-aadvance-analogue-input-termination-assembly","title":"T9832 ICS Triplex AADvance Analogue Input Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ICS Triplex T9832 is a high-integrity Analogue Input Termination Assembly (TA) specifically designed for the AADvance™ functional safety system. This module serves as the critical physical and electrical interface between field-mounted analogue sensors and the AADvance controller’s input modules. Unlike standard termination units, the T9832 is engineered to support the sophisticated \"plug-and-play\" architecture of the AADvance series, allowing for seamless signal routing and redundant sensor configurations.\u003c\/p\u003e\n\u003cp\u003eDesigned to meet the high-availability requirements of Safety Instrumented Systems (SIS), the T9832 provides a secure termination point for 4-20mA or voltage-based analogue signals. Its compact, ultra-lightweight design facilitates high-density mounting on standard DIN rails, ensuring that critical process data—such as pressure, flow, and temperature—is delivered to the logic solver with maximum signal veracity and minimal electrical interference.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics and Functional Roles\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-529 citation-end-529\"\u003eThe T9832 is built for mission-critical reliability, acting as the foundation for the AADvance system's distributed I\/O capability.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Signal Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a transparent and stable path for analogue field signals, ensuring that the AADvance input modules can accurately perform Triple Modular Redundant (TMR) voting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures integrated bus structures that allow for the distribution of field power to sensors, supporting the high-availability requirements of industrial safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePassive Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a passive termination component, the T9832 boasts an exceptionally high MTBF, as it contains no active logic circuitry that could fail and interrupt the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe assembly allows for the online replacement of active I\/O modules without disturbing the field wiring, significantly reducing the risk of accidental wiring errors during system updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Grade Build:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically constructed to resist the vibration and thermal cycling common in oil, gas, and chemical processing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Compact Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring just 13x8.3x3.2cm, it optimizes rail space in high-density control cabinets, allowing for more I\/O points in a smaller footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eICS Triplex (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eT9832\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAADvance System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-528\"\u003e\u003c\/span\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"citation-528 citation-end-528\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalogue Input Termination Assembly (TA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.16 kg (0.35 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e13.0 x 8.3 x 3.2 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN Rail (integrated locking mechanism)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports standard analogue input field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for SIL 3 rated applications when used in TMR configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-527\"\u003e\u003c\/span\u003e\u003cstrong\u003eHS Code:\u003c\/strong\u003e\u003cspan class=\"citation-527 citation-end-527\"\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Reliability and Integration\u003c\/h3\u003e\n\u003cp\u003eThe T9832 is a cornerstone of the AADvance system’s flexibility. It is frequently utilized in Emergency Shutdown (ESD) and Fire and Gas (F\u0026amp;G) applications where the integrity of analogue measurements is paramount. By providing a rugged and vibration-resistant termination point, the T9832 ensures that transient noise and mechanical stress do not compromise the safety integrity of the control loop.\u003c\/p\u003e\n\u003cp\u003eFor system integrators, the T9832 simplifies cabinet design by providing clear, labeled termination points that integrate directly with AADvance I\/O module bases. This structured approach to wiring reduces commissioning time and ensures that the system is easily scalable for future operational expansions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519056404653,"sku":"T9832","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ics-triplex-t9832-analogue-input-termination-assembly-mtpjr2vkwzl.jpg?v=1766985824","url":"https:\/\/www.maxwellplc.com\/products\/t9832-ics-triplex-aadvance-analogue-input-termination-assembly","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}