{"product_id":"spa-zc21-abb-spacom-bus-connection-module","title":"SPA-ZC21 ABB SPACOM Bus Connection Module","description":"\u003cp\u003eConfigured for optical signal conversion in SPACOM automation platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB SPA-ZC21\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eSPA-ZC21\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBus Connection Module) provides direct physical and electrical execution of opto-electrical signal translation between fiber-optic and RS485 interfaces.\u003c\/p\u003e\n\u003ch3\u003eModel Identifier Matrix\u003c\/h3\u003e\n\u003cp\u003eThe SPA-ZC21 is a standardized opto-electrical interface unit. The model designation specifies the signal conversion capability, and the unit is supplied as a self-contained module without modular sub-assembly options. All functional modes are established via integrated hardware DIP switches.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPA-ZC21\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.0 x 19.0 x 5.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Host-derived)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPA \/ RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiber-Optic \/ 9-pin D-type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe SPA-ZC21 maintains backplane bus communication velocity sufficient for substation protection telemetry. It supports deterministic signal conversion between optical and electrical mediums, ensuring synchronization with host relays. The module does not require dedicated power supply routing, as it extracts operational current from the host device’s serial port interface. It supports I\/O density scaling by allowing multi-unit daisy-chaining of optical nodes. The internal logic handles firmware flash compatibility through the protocol handshake, ensuring standard baud rate alignment across the SPA bus architecture.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSPA-ZC21 Bus Connection Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical integration guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielded connector interface assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Attach the module directly to the 9-pin D-type port of the host protection relay; ensure the mechanical locking screws are tightened to prevent vibration loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFiber Optic: Verify that fiber-optic connectors are clean and free of particulate matter before insertion to prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching: Set the integrated DIP switches to the required protocol (SPA or RS485) and echo check configuration prior to powering the host relay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the host device is properly grounded to the cabinet chassis to maintain signal reference levels for the electrical port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification: Monitor the status indicators on the host device to confirm successful optical link establishment and communication handshake.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the SPA-ZC21 require an external power supply?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit is designed for passive operation, drawing power directly from the host device’s serial port connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the SPA-ZC21 hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No. The host device should be powered down or the port isolated before installing or removing the module to prevent electrical transients at the D-type interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the integrated echo check function?\u003c\/p\u003e\n\u003cp\u003eA: The echo check validates that transmitted data is received correctly by the bus, preventing signal corruption in complex communication loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the module be used with both glass and plastic fiber optics?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports standard fiber types; ensure the optical connector matches the specific fiber termination used in the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are communication protocols changed?\u003c\/p\u003e\n\u003cp\u003eA: Configuration is performed via on-board DIP switches, which toggle between SPA and RS485 protocol settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates that the optical link is degraded?\u003c\/p\u003e\n\u003cp\u003eA: Signal degradation is reported as communication errors or increased packet retransmission counts within the host relay’s diagnostic logs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this in an environment with high electromagnetic noise?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The fiber-optic interface provides complete galvanic isolation, eliminating the risk of electrical noise interference common in substations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What baud rates does the SPA-ZC21 support?\u003c\/p\u003e\n\u003cp\u003eA: The module supports standard SPA bus baud rates as defined by the host protection relay's configuration settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231159509165,"sku":"SPA-ZC21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-spa-zc21-bus-connection-module-a1onrh15mlf_ff6f2c40-e54b-4bba-97f4-40383f762a87.jpg?v=1762942174","url":"https:\/\/www.maxwellplc.com\/products\/spa-zc21-abb-spacom-bus-connection-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}