{"product_id":"siemens-6es7972-0aa02-0xa0-simatic-dp-rs485-repeater","title":"Siemens 6ES7972-0AA02-0XA0 SIMATIC DP RS485 Repeater","description":"\u003cp\u003eThe Siemens 6ES7972-0AA02-0XA0 is a SIMATIC DP RS485 Repeater designed to connect PROFIBUS and MPI bus systems. It regenerates RS485 signals, helping extend network segments and improve communication reliability. The repeater supports transmission rates from 9.6 kbit\/s to 12 Mbit\/s and accommodates up to 31 nodes. It features IP20 protection, a 24 VDC power supply, two PROFIBUS terminal blocks, and a PG\/OP interface for programming and operator devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 6ES7972-0AA02-0XA0 belongs to Siemens SIMATIC DP communication accessories. It is used in PROFIBUS\/MPI networks to connect bus segments and support communication over extended industrial installations.\u003c\/p\u003e\n\u003cp\u003eAs an RS485 repeater, the device receives and regenerates bus signals between connected segments. This helps maintain signal quality and supports network expansion where cable length or node distribution requires additional segmentation.\u003c\/p\u003e\n\u003cp\u003eThe unit also provides diagnostic and commissioning features. These include segment separation switches and bus activity indicators, helping technicians inspect and troubleshoot network operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens SIMATIC DP communication accessory\u003c\/li\u003e\n\u003cli\u003eRS485 repeater for PROFIBUS and MPI bus systems\u003c\/li\u003e\n\u003cli\u003eSupports transmission rates from 9.6 kbit\/s to 12 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eSupports up to 31 nodes\u003c\/li\u003e\n\u003cli\u003e24 VDC external power supply\u003c\/li\u003e\n\u003cli\u003eTwo terminal blocks for PROFIBUS cable connections\u003c\/li\u003e\n\u003cli\u003eIntegrated PG\/OP interface\u003c\/li\u003e\n\u003cli\u003eIP20 degree of protection\u003c\/li\u003e\n\u003cli\u003eSegment separation switches for commissioning\u003c\/li\u003e\n\u003cli\u003eBus activity indication\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7972-0AA02-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSIMATIC DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRS485 Repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Bus Systems\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS \/ MPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Number of Nodes\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e20.4–28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA, depending on PG\/OP socket load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Loss\u003c\/td\u003e\n\u003ctd\u003e0.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS Connections\u003c\/td\u003e\n\u003ctd\u003e2 terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Interface\u003c\/td\u003e\n\u003ctd\u003ePG\/OP interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Depth\u003c\/td\u003e\n\u003ctd\u003e59.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Approximate Weight\u003c\/td\u003e\n\u003ctd\u003e350 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Network Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe RS485 repeater connects PROFIBUS or MPI network segments while regenerating communication signals. This allows engineers to expand bus installations and improve signal transmission across distributed equipment.\u003c\/p\u003e\n\u003cp\u003eThe device supports transmission rates from 9.6 kbit\/s through 12 Mbit\/s. Its two PROFIBUS terminal blocks provide connections for the bus segments.\u003c\/p\u003e\n\u003cp\u003eThe integrated PG\/OP interface provides an additional connection point for programming devices or operator panels. This is useful during commissioning, maintenance, and system diagnostics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic and Commissioning Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 6ES7972-0AA02-0XA0 provides functions designed to support network commissioning and troubleshooting.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSegment separation switches allow the two bus segments to be separated.\u003c\/li\u003e\n\u003cli\u003eBus activity indicators help technicians observe communication activity.\u003c\/li\u003e\n\u003cli\u003eThe repeater supports isolation of segments under certain interference conditions.\u003c\/li\u003e\n\u003cli\u003eThe PG\/OP interface provides access for compatible programming and operator devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese features help maintenance personnel identify communication issues and inspect network segments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe repeater is intended for Siemens SIMATIC DP installations using compatible PROFIBUS or MPI communication networks.\u003c\/p\u003e\n\u003cp\u003eBefore installation, check the network transmission rate, cable arrangement, node count, and power supply requirements.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMount the repeater on a suitable DIN rail.\u003c\/li\u003e\n\u003cli\u003eConnect the external 24 VDC supply.\u003c\/li\u003e\n\u003cli\u003eConnect the PROFIBUS cables to the designated terminal blocks.\u003c\/li\u003e\n\u003cli\u003eCheck bus polarity and cable shielding according to Siemens installation instructions.\u003c\/li\u003e\n\u003cli\u003eVerify the required transmission rate and network configuration.\u003c\/li\u003e\n\u003cli\u003eCheck bus activity indicators after powering the system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe device has IP20 protection and should be installed inside a suitable electrical cabinet or protected enclosure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is Siemens 6ES7972-0AA02-0XA0?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a SIMATIC DP RS485 Repeater used to connect PROFIBUS and MPI bus segments in industrial automation networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What communication protocols does this repeater support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed for PROFIBUS and MPI bus systems using RS485 communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What is the maximum transmission speed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe repeater supports transmission rates up to 12 Mbit\/s, with a documented range starting at 9.6 kbit\/s.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. How many nodes can the repeater support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens product description specifies a maximum of 31 nodes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What power supply does the unit require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires an external 24 VDC supply. The permitted input voltage range is 20.4–28.8 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Does the 6ES7972-0AA02-0XA0 have a programming interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It includes a PG\/OP interface for compatible programming devices and operator panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. What are the dimensions and weight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe technical datasheet specifies dimensions of 45 × 128 × 59.3 mm and an approximate weight of 350 g.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What is the protection rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe repeater has an IP20 protection rating and should be installed in a suitable protected industrial enclosure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated Siemens Products\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens 6ES7972-0BA12-0XA0 – PROFIBUS bus connector\u003c\/li\u003e\n\u003cli\u003eSiemens 6ES7972-0BB12-0XA0 – PROFIBUS bus connector with PG socket\u003c\/li\u003e\n\u003cli\u003eSiemens 6ES7972-0DA00-0AA0 – PROFIBUS diagnostic repeater\u003c\/li\u003e\n\u003cli\u003eSiemens 6ES7315-2AG10-0AB0 – SIMATIC S7-300 CPU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":68382892425389,"sku":"6ES7972-0AA02-0XA0","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/6es7972-0aa02-0xa0-1.jpg?v=1795164108","url":"https:\/\/www.maxwellplc.com\/products\/siemens-6es7972-0aa02-0xa0-simatic-dp-rs485-repeater","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}