{"product_id":"siemens-6es7431-1kf10-0ab0-simatic-s7-400-sm-431-analog-input-module","title":"Siemens 6ES7431-1KF10-0AB0 SIMATIC S7-400 SM 431 Analog Input Module","description":"\u003cp\u003eThe Siemens 6ES7431-1KF10-0AB0 is an SM 431 analog input module designed for SIMATIC S7-400 PLC systems. It provides eight analog input channels for voltage and current measurement, with four channels additionally supporting resistance, thermocouple, and resistance thermometer measurements. The module offers 14-bit resolution, increasing to 16 bits when filtering is activated. It supports applications requiring flexible process signal acquisition across industrial automation systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 6ES7431-1KF10-0AB0 belongs to the Siemens SIMATIC S7-400 SM 431 analog input module family. It acquires different types of analog signals from field instruments and makes the measured values available to the PLC control system.\u003c\/p\u003e\n\u003cp\u003eThe module provides eight channels for voltage and current measurement. Four of these channels can also be configured for resistance measurement, thermocouples, and resistance thermometers.\u003c\/p\u003e\n\u003cp\u003eThis flexibility makes the module suitable for applications combining conventional process transmitters with temperature and resistance-based instruments. Supported temperature sensors include various thermocouple types and Pt100 resistance thermometers.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens SIMATIC S7-400 SM 431 analog input module\u003c\/li\u003e\n\u003cli\u003eEight analog input channels\u003c\/li\u003e\n\u003cli\u003e14-bit resolution with overrange\u003c\/li\u003e\n\u003cli\u003eUp to 16-bit resolution with activated filtering\u003c\/li\u003e\n\u003cli\u003eVoltage and current measurement on eight channels\u003c\/li\u003e\n\u003cli\u003eResistance, thermocouple, and RTD measurement on four channels\u003c\/li\u003e\n\u003cli\u003eSupports 0–20 mA and 4–20 mA signals\u003c\/li\u003e\n\u003cli\u003eSupports multiple voltage measurement ranges\u003c\/li\u003e\n\u003cli\u003eCompatible with Pt100, Pt200, Pt500, Pt1000, Ni100, and Ni1000 sensors\u003c\/li\u003e\n\u003cli\u003e24 VDC load voltage for supplying two-wire transmitters\u003c\/li\u003e\n\u003cli\u003eTypical power loss of 3.5 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Series\u003c\/td\u003e\n\u003ctd\u003eSM 431\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number\u003c\/td\u003e\n\u003ctd\u003e6ES7431-1KF10-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Current Measurement\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Measurement\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Measurement\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Thermometer Measurement\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution with Filtering\u003c\/td\u003e\n\u003ctd\u003eUp to 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Ranges\u003c\/td\u003e\n\u003ctd\u003e±80 mV, ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, 1–5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0–48 Ω, 0–150 Ω, 0–300 Ω, 0–600 Ω, 0–6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eB, E, J, K, L, N, R, S, T, U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Thermometers\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt200, Pt500, Pt1000, Pt10000, Ni100, Ni1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage L+\u003c\/td\u003e\n\u003ctd\u003e24 VDC, required for supplying two-wire transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current from L+\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Backplane Bus Current\u003c\/td\u003e\n\u003ctd\u003e600 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Loss\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Conversion Time\u003c\/td\u003e\n\u003ctd\u003e20.1 \/ 23.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Frequency Suppression\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Shielded Cable Length\u003c\/td\u003e\n\u003ctd\u003e200 m; 50 m for thermocouples and input ranges ≤80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential Separation\u003c\/td\u003e\n\u003ctd\u003eBetween analog section and backplane bus; not between individual channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e25 × 290 × 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400 PLC rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial analog signal acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Signal Measurement Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SM 431 supports several input signal categories, allowing different field instruments to connect to the same module type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports multiple voltage ranges, including ±80 mV, ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, and 1–5 V. These ranges accommodate different process measurement and instrumentation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accepts 0–20 mA and 4–20 mA signals. It supports two-wire and four-wire transmitter connections, making it suitable for common industrial process transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResistance and Temperature Measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFour channels support resistance-based measurement and temperature sensing. Compatible sensors include Pt100, Pt200, Pt500, Pt1000, Ni100, and Ni1000 resistance thermometers.\u003c\/p\u003e\n\u003cp\u003eThe module also supports thermocouple types B, E, J, K, L, N, R, S, T, and U. External temperature compensation can be configured using a Pt100 sensor or compensation socket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eResolution and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides a maximum resolution of 14 bits, including overrange and sign. When filtering is activated, the resolution can reach 16 bits.\u003c\/p\u003e\n\u003cp\u003eIntegration time is parameterizable, allowing the module to be configured according to signal acquisition requirements. It also provides 50 Hz and 60 Hz interference suppression to help reduce the influence of common power-frequency interference.\u003c\/p\u003e\n\u003cp\u003eThe basic conversion time is specified as 20.1 or 23.5 ms, depending on the configured operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process temperature monitoring\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical process control\u003c\/li\u003e\n\u003cli\u003ePower generation instrumentation\u003c\/li\u003e\n\u003cli\u003eOil and gas process measurement\u003c\/li\u003e\n\u003cli\u003ePressure and flow transmitter signal acquisition\u003c\/li\u003e\n\u003cli\u003eResistance temperature detector monitoring\u003c\/li\u003e\n\u003cli\u003eThermocouple temperature measurement\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery monitoring\u003c\/li\u003e\n\u003cli\u003eExisting SIMATIC S7-400 system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 6ES7431-1KF10-0AB0 is designed for the Siemens SIMATIC S7-400 PLC platform. It occupies one module slot in the S7-400 rack.\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the CPU and rack configuration, module addressing, signal wiring, and channel parameters. The selected input type must match the connected field instrument.\u003c\/p\u003e\n\u003cp\u003eAlthough the module supports several signal types, the resistance, thermocouple, and resistance thermometer functions are limited to four channels. Confirm the channel allocation before designing or modifying an I\/O configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Configuration Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a compatible SIMATIC S7-400 rack following Siemens installation instructions.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the complete order number 6ES7431-1KF10-0AB0.\u003c\/li\u003e\n\u003cli\u003eConfirm the available rack slot and system configuration.\u003c\/li\u003e\n\u003cli\u003eCheck the required signal type for each input channel.\u003c\/li\u003e\n\u003cli\u003eConfigure the appropriate voltage or current measurement range.\u003c\/li\u003e\n\u003cli\u003eSet thermocouple or RTD parameters where applicable.\u003c\/li\u003e\n\u003cli\u003eVerify transmitter power requirements and wiring.\u003c\/li\u003e\n\u003cli\u003eUse suitable shielded signal cables.\u003c\/li\u003e\n\u003cli\u003eCheck grounding and potential separation requirements.\u003c\/li\u003e\n\u003cli\u003eValidate measured values during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module does not provide channel-to-channel galvanic isolation. Its documented potential separation applies between the analog section and other specified system potentials. Follow Siemens wiring and isolation requirements when connecting field instruments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Lifecycle Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAccording to the Siemens product lifecycle information supplied for this model, phase-out began on October 1, 2025, and product cancellation took effect on October 1, 2026.\u003c\/p\u003e\n\u003cp\u003eAs of November 2026, the module should be treated as a discontinued product for replacement and maintenance planning. Existing installations may continue using the module, subject to system condition and application requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Siemens 6ES7431-1KF10-0AB0?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is an SM 431 analog input module designed for Siemens SIMATIC S7-400 PLC systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many analog input channels does this module provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides eight analog input channels for voltage and current measurement. Four channels additionally support resistance, thermocouple, and resistance thermometer measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What is the resolution of the 6ES7431-1KF10-0AB0?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides 14-bit resolution, with up to 16-bit resolution when filtering is activated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Does this module support 4–20 mA signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports both 0–20 mA and 4–20 mA current input ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Which thermocouple types are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupported types include B, E, J, K, L, N, R, S, T, and U.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Can the module measure Pt100 temperature sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports Pt100 and several other resistance thermometer types, including Pt200, Pt500, Pt1000, Ni100, and Ni1000.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Does the module require an external 24 VDC supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 24 VDC load voltage is required when supplying two-wire transmitters. The module also draws power from the S7-400 backplane bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. Is the 6ES7431-1KF10-0AB0 discontinued?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccording to the lifecycle information supplied, cancellation took effect on October 1, 2026. Verify current availability before planning a replacement purchase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated Products\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens 6ES7431-1KF00-0AB0 SM 431 Analog Input Module\u003c\/li\u003e\n\u003cli\u003eSiemens 6ES7431-1KF20-0AB0 SM 431 Analog Input Module\u003c\/li\u003e\n\u003cli\u003eSiemens 6ES7431-7KF00-0AB0 SM 431 Analog Input Module\u003c\/li\u003e\n\u003cli\u003eSiemens SIMATIC S7-400 Central Processing Units\u003c\/li\u003e\n\u003cli\u003eSiemens SIMATIC S7-400 Signal Modules\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":68380065562797,"sku":"6ES7431-1KF10-0AB0","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/6es7431-1kf10-0ab0-1.jpg?v=1795152924","url":"https:\/\/www.maxwellplc.com\/products\/siemens-6es7431-1kf10-0ab0-simatic-s7-400-sm-431-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}