{"product_id":"siemens-6es7155-5aa01-0ab0-profinet-im-155-5-pn-st-interface-module","title":"Siemens 6ES7155-5AA01-0AB0 PROFINET IM 155-5 PN ST Interface Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Siemens 6ES7155-5AA01-0AB0 is a high-performance IM 155-5 PN ST interface module designed to act as the primary communication link for the SIMATIC ET 200MP distributed I\/O system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module facilitates the connection between a PROFINET IO controller and the local I\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeffectively functioning as a transparent gateway for industrial data.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for the S7-1500 family,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit allows for the decentralized setup of control systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting a massive array of up to 30 I\/O modules when properly powered.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith its integrated 2-port switch,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit simplifies network cabling by allowing daisy-chaining (line topology) without the need for external industrial switches.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSystem Specifications and Networking Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis interface head station is characterized by its deterministic communication capabilities and its high-density module management within the TIA Portal environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePROFINET IO with integrated 2-port switch (RJ45).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 12 modules (no additional PS) or up to 30 modules (with additional PS).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eShortest Cycle Time:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e25 ms for high-speed synchronization.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtocol Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePROFINET IRT (Isochronous Real-Time) and MRP (Media Redundancy Protocol).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStartup Speed:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports Fast Startup (FSU) in under 500 ms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCabling Flexibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAuto-crossover and auto-negotiation supported on both ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Features:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated I\u0026amp;M data (0 to 3) for digital asset tracking.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e35 mm (W) x 147 mm (H) x 129 mm (D).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDevice Weight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e25 kg (Net) \/ 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e95 kg (Gross shipping weight).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eStrategic Industrial Usage\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Speed Synchronized Manufacturing\u003c\/strong\u003e\u003cspan class=\"\"\u003eIn robotic assembly and high-speed motion control,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe IRT (Isochronous Real-Time) support of the 6ES7155-5AA01-0AB0 is critical.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt ensures that data packets are delivered with microsecond precision,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for perfectly timed coordination between multiple axes and decentralized sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLarge-Scale Infrastructure Redundancy\u003c\/strong\u003e\u003cspan class=\"\"\u003eFor systems that cannot afford a network break,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as tunnel ventilation or water treatment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe Media Redundancy Protocol (MRP) allows the IM 155-5 to operate in a ring topology.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf a PROFINET cable is damaged,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe system reroutes communication instantly to maintain operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModular Machine Building\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe \"Fast Startup\" capability is a game-changer for tool-changing applications or modular production cells.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen a module is plugged into the system,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit becomes operational in less than half a second,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eminimizing the idle time during machine reconfigurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDistributed Control in Automotive Plants\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe ET 200MP system,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eled by this interface module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprovides a space-efficient way to distribute I\/O across large assembly halls.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing PROFINET,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 6ES7155-5AA01-0AB0 reduces copper wiring costs by localizing the I\/O near the actuators and sending all data back to the central S7-1500 CPU via a single industrial Ethernet cable.\u003c\/span\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":45519024390317,"sku":"6ES7155-5AA01-0AB0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/siemens-6es7155-5aa01-0ab0-interface-module-todaetatu4p.jpg?v=1766984989","url":"https:\/\/www.maxwellplc.com\/products\/siemens-6es7155-5aa01-0ab0-profinet-im-155-5-pn-st-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}