{"product_id":"siemens-6es7138-4cf03-0ab0-simatic-et-200s-pm-e-f-profisafe-power-module","title":"Siemens 6ES7138-4CF03-0AB0 SIMATIC ET 200S PM-E F PROFIsafe Power Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 6ES7138-4CF03-0AB0 is a high-integrity safety power module (PM-E F) designed for the Siemens SIMATIC ET 200S distributed I\/O system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is engineered to provide fail-safe monitoring and switching of the 24V DC potential groups within a PROFIsafe architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating specialized relay circuitry,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module can safely disconnect the power supply to downstream standard or safety-related modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring a coordinated emergency stop or safety shutdown.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt serves as a critical junction point for distributed safety logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for the creation of localized safety zones within a larger industrial network without the need for complex,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecentralized safety wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eFunctional Safety and Hardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Compliance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAchieves up to SIL 3 (IEC 61508),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePL e (ISO 13849-1),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Category 4 (EN 954-1).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePotential Group Switching:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures internal relays for the safe disconnection of the P1 and P2 voltage buses.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFail-Safe Outputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with 2 dedicated fail-safe digital outputs for controlling external safety actuators.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports PROFIsafe communication via PROFIBUS DP or PROFINET (when paired with high-feature interface modules like IM 151-3 HF).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInsulation Integrity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDielectric strength tested up to 500V DC to ensure circuit separation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVoltage Monitoring:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eReal-time diagnostics for under-voltage and load voltage status.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGrounding Versatility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for operation in systems with ungrounded (floating) reference potentials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eForm Factor:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard 30mm ET 200S module width with a lightweight 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e24 kg construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and System Implementation\u003c\/h3\u003e\n\u003ch3 class=\"\"\u003eIntegrated Machine Safety Zones\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 6ES7133-4CF03-0AB0 is primarily used to define safety segments on production lines.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen a light curtain or emergency stop button is triggered,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module can immediately kill power to a specific group of motor starters or valves while allowing the rest of the machine to remain powered,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating a controlled and safe local stoppage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eAutomotive Assembly and Robotics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIn robotic cells where human-machine interaction is frequent,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis PROFIsafe module manages the safety-related digital outputs that control gate interlocks and robot \"Enable\" signals.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts high SIL3 rating ensures that safety commands are executed with the highest level of reliability required for automotive manufacturing standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eDistributed Safety for Logistics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eFor expansive conveyor systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 6ES7138-4CF03-0AB0 allows safety logic to be distributed across long distances via PROFINET.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis decentralization significantly reduces the cost of running dedicated safety cables from the field back to the main control room,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eas the safety data travels over the existing industrial network.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eFail-Safe Power Management in Harsh Environments\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDesigned for continuous industrial use,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module provides stable 24V DC distribution even in environments prone to electrical noise.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts ability to monitor its own health and report diagnostic data to the PLC makes it an essential component for predictive maintenance and reducing unplanned downtime in critical process industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":45519027077293,"sku":"6ES7138-4CF03-0AB0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/siemens-6es7138-4cf03-0ab0-dp-power-module-b5skbyhww4n.jpg?v=1766985097","url":"https:\/\/www.maxwellplc.com\/products\/siemens-6es7138-4cf03-0ab0-simatic-et-200s-pm-e-f-profisafe-power-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}