{"product_id":"sdcs-pow-h01-abb-power-supply-board-advant-ocs-800xa","title":"SDCS-POW-H01 ABB Power Supply Board Advant OCS 800xA","description":"\u003cp\u003eConfigured for power regulation in DCS800 and Advant OCS architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB SDCS-POW-H01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eSDCS-POW-H01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Board) provides direct electrical conversion and distribution for drive control electronics. This module is engineered to accept diverse input voltage ranges and transform them into stable DC rails required by the system backplane and associated control interfaces. The unit ensures consistent energy delivery to internal logic components, maintaining signal integrity and operational stability during standard drive modulation cycles. It is designed for integration into modular cabinet layouts, facilitating power management for industrial drive control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Identification\u003c\/h3\u003e\n\u003cp\u003eThe module is identified by the part number 3ADT318700R1501. There are no user-configurable hardware sub-variants or functional suffixes associated with this specific board revision.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Mechanical Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSDCS-POW-H01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3ADT318700R1501\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.2 x 9.7 x 4.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–30 VDC, 100–240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–10 A continuous (15 A peak)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl System Integration\u003c\/h3\u003e\n\u003cp\u003eThe SDCS-POW-H01 is architected to interface with the ABB Advant OCS and 800xA backplane communication structures. The board logic facilitates deterministic power distribution to ensure that the I\/O density scaling and processor cycles remain within specified tolerances. By stabilizing the internal voltage rails, the board prevents fluctuations that could otherwise impact firmware flash compatibility or induce noise on the deterministic network. The circuitry is designed to maintain precise voltage regulation even under transient load conditions characteristic of high-performance industrial drive control environments.\u003c\/p\u003e\n\u003ch3\u003eOrdering and Package Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSDCS-POW-H01 Power Supply Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard static-shielded packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation insert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo secondary cables or backplane adapters included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: The module chassis must be connected to the cabinet common ground point via the designated mounting hardware to ensure electromagnetic compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Constraints: Ensure input power leads are sized according to the peak 15 A current draw. Maintain physical separation between power input wiring and low-voltage signal communication cables to prevent induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Use shielded cabling for all AC input lines. The shield should be terminated at the cabinet entry point to suppress high-frequency noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Insertion: Ensure the module is fully seated within the drive rack guide rails before applying input power to prevent connector pin arching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this board support hot-swap functionality?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, the system must be powered down and the DC bus discharged before removing or inserting the board to prevent damage to the backplane connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the output voltage regulated during transient loads?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The internal feedback loop maintains constant voltage regulation by adjusting the switching duty cycle to compensate for rapid load fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this module compatible with non-DCS800 series drives?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Compatibility is limited to systems utilizing the Advant OCS\/800xA architecture; verify the specific rack interface before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the board require external cooling?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: It is designed for operation in forced-air cooled cabinets; ensure that airflow paths remain unobstructed by cabling or other modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the unit manage AC input frequency variations?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The internal power stage is designed to accommodate 50 Hz and 60 Hz grids without modification to the output regulation parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I connect multiple boards in parallel for higher current?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, parallel connection is not supported; the load must be distributed according to the design limits of individual rack slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a failure of the power supply?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Failure is typically indicated by the loss of the diagnostic heartbeat signal on the backplane or the absence of regulated DC output rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the input voltage auto-ranging?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the power supply stage utilizes auto-ranging circuitry to accommodate the specified DC and AC input ranges automatically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231179628717,"sku":"3ADT318700R1501","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-sdcs-pow-h01-3adt318700r1501-power-supply-board-kmafaed05mc_c53205a9-3407-4792-8ee0-cac18c3c1a6d.jpg?v=1762942330","url":"https:\/\/www.maxwellplc.com\/products\/sdcs-pow-h01-abb-power-supply-board-advant-ocs-800xa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}