{"product_id":"sc-umix01-51307547-175-honeywell-controledge-rtu-mixed-i-o-module","title":"SC-UMIX01 51307547-175 Honeywell ControlEdge RTU Mixed I\/O Module","description":"\u003cp\u003eConfigured for universal mixed signal processing in ControlEdge RTU platforms, the \u003cstrong\u003eHoneywell SC-UMIX01 51307547-175\u003c\/strong\u003e (\u003cstrong\u003eSC-UMIX01\u003c\/strong\u003e Mixed Universal Input\/Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Part Identification Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Module Designation: SC-UMIX01\u003c\/li\u003e\n\u003cli\u003eManufacturing Part Number: 51307547-175\u003c\/li\u003e\n\u003cli\u003eSystem Platform Series: ControlEdge RTU and PLC Series\u003c\/li\u003e\n\u003cli\u003eHardware Classification: Mixed Universal Input\/Output Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSC-UMIX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e14.5 cm x 14 cm x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial control cabinet range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane rail power load dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Performance\u003c\/td\u003e\n\u003ctd\u003eUniversal mixed analog and digital signal conditioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Loop Integration and DCS Communication\u003c\/h3\u003e\n\u003cp\u003eThis hardware integrates into the control network to manage diverse signal types through a unified interface. It supports 4-20 mA HART loop protocol parameters and channel-to-channel isolation to prevent electrical interference across mixed analog and digital signal lines. Cold junction compensation (CJC) and precise signal conditioning maintain loop fidelity for critical field instrumentation without inducing common-mode voltage errors.\u003c\/p\u003e\n\u003ch3\u003eOrder Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x SC-UMIX01 mixed I\/O module unit\u003c\/li\u003e\n\u003cli\u003e1 x DIN-rail mounting locking bracket\u003c\/li\u003e\n\u003cli\u003e1 x Terminal block connector interface set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Snap the module securely onto a standard grounded DIN rail within the industrial control enclosure, ensuring proper mechanical locking.\u003c\/li\u003e\n\u003cli\u003eShield Termination: Ground all analog signal cable shields at a single-point earth ground bar to suppress electromagnetic noise propagation.\u003c\/li\u003e\n\u003cli\u003eWiring Clearance: Separate low-voltage signal wiring from high-voltage power conduits to maintain signal integrity across channel connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal types are supported by this hardware module?\u003c\/p\u003e\n\u003cp\u003eThe unit processes a combination of analog input, analog output, digital input, and digital output points through universal terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support online firmware flashing or version checking?\u003c\/p\u003e\n\u003cp\u003eIt is optimized for firmware version 174.1.21.0 and higher, supporting cross-version connectivity for diagnostic verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre specific grounding precautions required during signal wiring?\u003c\/p\u003e\n\u003cp\u003eYes, signal shields must maintain proper termination to prevent ground loops and common-mode interference in noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be hot-swapped in active control racks?\u003c\/p\u003e\n\u003cp\u003eHot-swap execution depends on system-level backplane power architecture; verify rack power states prior to module handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the module configured during commissioning?\u003c\/p\u003e\n\u003cp\u003eConfiguration is executed through the Honeywell ControlEdge Builder engineering software environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical dimensions of the hardware housing?\u003c\/p\u003e\n\u003cp\u003eThe unit dimensions measure approximately 7 cm in depth, 14 cm in width, and 14.5 cm in height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the hardware handle electrical noise isolation?\u003c\/p\u003e\n\u003cp\u003eIt incorporates robust channel-to-system isolation barriers to protect internal processing circuitry from external transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat system families are compatible with this I\/O card?\u003c\/p\u003e\n\u003cp\u003eIt is engineered specifically for integration within ControlEdge 2020 RTU and ControlEdge PLC controller platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518952726701,"sku":"SC-UMIX01 51307547-175","price":888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/SC-UMIX0151307550-175_3_05.jpg?v=1784799914","url":"https:\/\/www.maxwellplc.com\/products\/sc-umix01-51307547-175-honeywell-controledge-rtu-mixed-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}