{"product_id":"sai143-h63-prp-yokogawa-16-channel-analog-input-module-prm-support","title":"SAI143-H63\/PRP Yokogawa 16-Channel Analog Input Module PRM Support","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa SAI143-H63\/PRP is a high-precision current input module developed for the ProSafe-RS safety instrumented system and CENTUM series architectures. Featuring 16 isolated channels, this module is engineered to capture 4 to 20 mA signals from field transmitters with extreme reliability. The \"H\" designation signifies enhanced accuracy and full compatibility with Plant Resource Manager (PRM) software, allowing for advanced device heartbeats and remote diagnostics. By providing a 1.5 kV AC dielectric strength between the field signals and the internal system logic, the SAI143-H63\/PRP ensures that process disturbances or electrical faults do not compromise the integrity of the primary control network.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters and Electrical Profile\u003c\/h3\u003e\n\u003cp\u003eThis module utilizes a sophisticated input protection circuit and flexible wiring configurations to suit various industrial sensor types.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Architecture\u003c\/strong\u003e: 16 Isolated Channels (Module-to-System Isolation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e: 4 to 20 mA DC (Operational range 0 to 25 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Rating\u003c\/strong\u003e: ±16 μA across a wide input spectrum (0.05 to 23 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRefresh Rate\u003c\/strong\u003e: 40-millisecond data update frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance (Active)\u003c\/strong\u003e: 250 Ω plus voltage drop in protection circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Grade\u003c\/strong\u003e: 1.5 kV AC withstand voltage for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmitter Power\u003c\/strong\u003e: Integrated 24V supply (16.15V min at 20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Stability\u003c\/strong\u003e: Max drift of ±16 μA per 10 °C change\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e: 320 mA (5V system) \/ 550 mA (24V system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMass\u003c\/strong\u003e: 0.34 kg to 0.39 kg (depending on terminal interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Footprint\u003c\/strong\u003e: Approximately 130 mm x 130 mm x 42 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications and Operational Context\u003c\/h3\u003e\n\u003cp\u003eThe SAI143-H63\/PRP is specifically designed for high-availability environments where signal precision and safety are paramount.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Instrumented Systems (SIS)\u003c\/strong\u003e: Serving as the primary input interface for Emergency Shutdown (ESD) systems where 4-20mA monitoring is critical for plant protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Asset Management\u003c\/strong\u003e: Utilizing the PRM support to monitor transmitter health and perform digital calibrations without manual field intervention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Field Wiring\u003c\/strong\u003e: Implementing both 2-wire and 4-wire transmitter configurations via individual channel pin settings, allowing for mixed-sensor loops on a single module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Power Environments\u003c\/strong\u003e: Deploying the unit in facilities with potential electrical noise, leveraging its high isolation and built-in transmitter power supply ON\/OFF functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SAI143-H63\/PRP power my 2-wire transmitters directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module includes a built-in transmitter power supply capable of delivering a minimum of 16.15 V at a full 20 mA load. This can be toggled for all 16 channels simultaneously in the 2-wire configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the SAI143-S and this SAI143-H model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"H\" version (High-accuracy\/HART) provides a wider accurate input range starting from 0.05 mA and includes full support for Yokogawa's Plant Resource Manager (PRM) for digital device management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I switch between 2-wire and 4-wire input modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The mode for each individual channel is determined by the physical setting of pins on the module, allowing for a customized mix of self-powered and loop-powered instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the input impedance if the system loses power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: When the power is OFF, the input impedance increases significantly to at least 500 kΩ, protecting the field loop and preventing excessive current draw during system downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which external connection methods are supported by this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module is highly adaptable, supporting pressure clamp terminal blocks, MIL cable interfaces, or dedicated Yokogawa signal cables via an interface adapter.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45878913826989,"sku":"SAI143-H63\/PRP","price":1580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/SAI143-H63_1.jpg?v=1775099671","url":"https:\/\/www.maxwellplc.com\/products\/sai143-h63-prp-yokogawa-16-channel-analog-input-module-prm-support","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}