{"product_id":"s8jx-g30024cd-omron-switch-mode-power-supply-s8jx-series","title":"S8JX-G30024CD Omron Switch Mode Power Supply S8JX Series","description":"\u003cp\u003eConfigured for regulated DC power conversion in industrial control panels, the \u003cstrong\u003eOmron S8JX-G30024CD\u003c\/strong\u003e (\u003cstrong\u003eS8JX-G30024CD\u003c\/strong\u003e Switch Mode Power Supply) provides direct physical\/electrical execution. It converts incoming AC line voltage into a stabilized 24 VDC output operating up to 300 W power capacity. Built inside a covered metallic enclosure with integral DIN rail mounting brackets, the unit delivers regulated DC voltage directly to field instrumentation and controller racks.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Model Code\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS8JX\u003c\/strong\u003e: Industrial switch mode power supply series platform index.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG\u003c\/strong\u003e: Standard functional configuration designator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300\u003c\/strong\u003e: 300 W output power capacity rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24\u003c\/strong\u003e: 24 VDC regulated output voltage rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC\u003c\/strong\u003e: Metal covered housing structure for internal circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Factory-installed 35 mm DIN rail mounting bracket option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS8JX-G30024CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20 x 15 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e300 W output rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eMetal covered frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIntegration Across Deterministic Automation Networks\u003c\/h3\u003e\n\u003cp\u003eSupplying regulated DC power to field nodes on Profinet \/ EtherNet\/IP deterministic networks, the power supply unit stabilizes system voltages across I\/O clusters. Proper voltage regulation maintains high backplane bus communication velocity and prevents communication frame drops caused by line sags. Stable DC power delivery ensures complete firmware flash compatibility and predictable processor boot cycles across modular control platforms.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron S8JX-G30024CD Switch Mode Power Supply\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Cover Plate\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Wiring \u0026amp; Mounting Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation\u003c\/strong\u003e: Snap the rear bracket top hook onto standard 35 mm DIN rail tracks and push downward until the bottom spring latch engages completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e: Terminate incoming AC mains leads and 24 VDC load cables to marked screw terminal blocks using correctly sized crimp lugs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Clearance\u003c\/strong\u003e: Maintain a minimum 20 mm clearance above and below the covered housing to facilitate unobstructed vertical convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding\u003c\/strong\u003e: Fasten a heavy-gauge earth grounding conductor firmly to the ground terminal to ensure noise mitigation and surge suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Avoid installing the power supply directly adjacent to major heat-generating sources inside enclosed electrical control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs live hot-swapping supported for the S8JX-G30024CD under electrical load?\u003c\/p\u003e\n\u003cp\u003eNo. Input AC mains power must be completely isolated before disconnecting wiring or unmounting the unit from the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output voltage is delivered by this power supply model?\u003c\/p\u003e\n\u003cp\u003eThe unit provides a factory-regulated 24 VDC nominal output rated for continuous loads up to 300 W total power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the power supply include a protective enclosure cover?\u003c\/p\u003e\n\u003cp\u003eYes. The \"C\" suffix indicates a fully covered metal chassis design that protects internal components from ambient debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the power supply mounted inside an electrical enclosure?\u003c\/p\u003e\n\u003cp\u003eThe \"D\" suffix configuration features an integrated rear clip assembly for standard 35 mm DIN rail mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does stable power delivery affect deterministic communication buses?\u003c\/p\u003e\n\u003cp\u003eRegulated DC power prevents voltage drops on field devices, preserving communication timing and frame delivery on industrial buses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat safety precautions apply during field wiring of AC input terminals?\u003c\/p\u003e\n\u003cp\u003eAlways ensure supply lines are de-energized and install protective terminal covers to prevent accidental contact with AC line potential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire size should be used for the output terminal connections?\u003c\/p\u003e\n\u003cp\u003eSelect conductor gauges rated to carry the maximum continuous output current without exceeding thermal wire isolation limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan multiple S8JX power supplies be connected in parallel without external diodes?\u003c\/p\u003e\n\u003cp\u003eNo. Connecting outputs in parallel requires external ORing diodes to prevent reverse current flow between power supply units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306662969517,"sku":"S8JX-G30024CD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/S8JX-G30024Cd-1.jpg?v=1790227584","url":"https:\/\/www.maxwellplc.com\/products\/s8jx-g30024cd-omron-switch-mode-power-supply-s8jx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}