{"product_id":"ref615e-d-2rca023019a0004c-abb-ref615-feeder-protection-and-control-relay","title":"REF615E-D 2RCA023019A0004C ABB REF615 Feeder Protection and Control Relay","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eABB REF615E-D 2RCA023019A0004C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, also cataloged as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eREF615\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Feeder Protection and Control Relay, processes feeder current signals and executes configured protection and control functions within the REF615 platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eModel and Ordering Code\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied identification includes REF615E-D, REF615, and ordering code 2RCA023019A0004C. The additional code HBFCACABNCA1BNN1XD is retained as supplied; its individual characters are not decoded because no verified coding matrix was provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHardware Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF615E-D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF615\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2RCA023019A0004C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFeeder Protection and Control Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePlatform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF615\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48-250 VDC \/ 100-240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current, I\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current, Io\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 10 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 x 10.8 x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipment Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXiamen, China\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eProtection Relay Electrical Interface\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe REF615E-D accepts current measurement inputs identified as I and Io, with the supplied configuration specifying 1\/5 A rated current values. The auxiliary supply range covers both AC and DC sources as specified above.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe relay is configured for feeder protection and control functions. Actual protection elements, binary I\/O assignments, communication interfaces, and application configuration depend on the specific REF615 variant and engineering settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eABB Protection and Control Characteristics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eREF615 is part of ABB's Relion protection and control product family. The relay processes measured electrical quantities and applies configured protection logic to feeder circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied unit is identified with 50\/60 Hz operation and less than 10 W power consumption. The auxiliary supply accepts 48-250 VDC or 100-240 VAC. Protection settings must correspond to the installed current transformer ratios and the configured application.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOrdering Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e1 x ABB REF615E-D Feeder Protection and Control Relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePart Number: 2RCA023019A0004C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModel: REF615E-D\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBase Platform: REF615\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1 x Relay hardware assembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo separate communication cable, terminal kit, mounting accessory, or configuration software is specified in the supplied product information.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation and Wiring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePanel installation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eConfirm the mounting cutout and mechanical dimensions against the applicable REF615 installation documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the relay with adequate clearance for terminal access and cable routing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify that the relay identification matches the intended protection application before energization.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eConfirm the available supply is within 48-250 VDC or 100-240 VAC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eObserve the correct polarity when using a DC auxiliary supply.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtect the auxiliary circuit according to the switchgear and protection-panel design.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDo not apply AC and DC auxiliary supplies simultaneously unless explicitly permitted by the applicable documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCurrent transformer circuits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eVerify CT secondary ratings against the configured 1\/5 A current inputs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConfirm I and Io wiring before commissioning.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCT secondary circuits must be handled according to the applicable protection-panel safety procedure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDo not open an energized CT secondary circuit.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eGrounding and signal routing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eConnect protective grounding according to the panel grounding design.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoute CT and communication wiring separately from high-current switching conductors where practical.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse the specified shield termination method for any shielded communication or signal cable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck terminal tightness and conductor identification before energizing the relay.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the auxiliary supply range of REF615E-D?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied identification specifies 48-250 VDC or 100-240 VAC for the auxiliary supply. The actual panel supply must remain within the applicable operating limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the rated current inputs?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied data identifies both I and Io inputs as 1\/5 A. CT secondary selection and relay settings must correspond to the installed protection circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the rated operating frequency?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specified rated frequency is 50\/60 Hz. The configured relay application must match the frequency of the monitored electrical system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the relay power consumption?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied product identification states power consumption of less than 10 W. Actual panel power calculations should use the applicable technical documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCan the relay be installed with an energized CT circuit?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cspan\u003eCT circuits should not be opened while energized. Follow the switchgear protection procedure and isolate or short the CT circuit as required before wiring work.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eDoes REF615E-D support both AC and DC auxiliary power?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The supplied identification specifies 48-250 VDC and 100-240 VAC auxiliary supply ranges. The selected source must be wired according to the relay terminal configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWhat should be checked before replacing the relay?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cspan\u003eVerify the REF615E-D model, 2RCA023019A0004C ordering code, CT ratings, auxiliary supply, wiring, and protection configuration before replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"auto\" class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eDoes the supplied data define the communication protocol?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"\"\u003e\u003cspan\u003eNo specific communication protocol is stated in the supplied data. Communication interfaces and protocol support should therefore be verified from the exact REF615 variant documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021066752173,"sku":"REF615E-D","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/REF615_2.jpg?v=1788326694","url":"https:\/\/www.maxwellplc.com\/products\/ref615e-d-2rca023019a0004c-abb-ref615-feeder-protection-and-control-relay","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}