{"product_id":"pw481-11-yokogawa-centum-vp-power-supply-module-100-120v-ac","title":"PW481-11 Yokogawa CENTUM VP Power Supply Module 100-120V AC","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa PW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands as a cornerstone of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Production Control System, delivering ultra-stable 24 VDC power to essential Field Control Units (FCU). In large-scale industrial operations, particularly those involving high-speed turbine monitoring and multi-stage compression strings, consistent power delivery is non-negotiable. This module ensures that precision instrumentation captures every nuance of mechanical vibration and process flow without electrical interference. By utilizing a high-efficiency conversion architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes thermal output while providing robust surge protection against line fluctuations. Whether supporting an AFV10S single unit or an AFV10D redundant configuration, this power supply guarantees the hardware availability required for 24\/7 continuous process control in the most demanding refinery and power plant environments.\u003c\/p\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a specific suffix code system to define its electrical compatibility and environmental hardening standards for the CENTUM VP ecosystem.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Analysis: PW481-11\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePW481\u003c\/strong\u003e: This designates the primary Power Supply Module series for FIO-based Field Control Units, specifically the AFV10 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-1\u003c\/strong\u003e: The first digit after the hyphen specifies the input voltage rating. A \"1\" indicates a 100 V to 120 V AC input range, optimized for specific regional utility standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: The second digit indicates the functional style and certification level. This version is built for standard mounting in global control cabinets, providing the necessary isolation and noise filtering required for high-density I\/O nests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 120 V AC (±10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 Hz to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 200 VA (Load-dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 25 A at 100 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC (Between input and logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 mm x 130 mm x 128 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 1.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in mission-critical applications where power failure equates to production loss. Unlike generic power supplies, this module features a specialized internal circuit that handles the high inrush currents typical of large DCS start-ups. It integrates perfectly with the CENTUM VP diagnostic bus, allowing the system to monitor the health of the power rails in real-time.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module supports a dual-redundant configuration. In this setup, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits balance the load; if one unit detects an internal fault or loses input power, the second unit immediately assumes the full load without a millisecond of drop-out. This seamless transition is vital for maintaining the integrity of safety instrumented functions (SIF) and high-speed control loops in hazardous environments.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eProper installation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures maximum MTBF (Mean Time Between Failure) for your control system.\u003c\/p\u003e\n\u003ch3\u003eRedundancy Setup\u003c\/h3\u003e\n\u003cp\u003eWhen installing in an AFV10D (Duplex) unit, ensure both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules are seated firmly in the dedicated power slots. Verify that both \"Ready\" LEDs are illuminated to confirm the redundant load-sharing mode is active.\u003c\/p\u003e\n\u003ch3\u003eGrounding Requirements\u003c\/h3\u003e\n\u003cp\u003eConnect the Frame Ground (FG) terminal using a dedicated grounding conductor with a resistance of 100 ohms or less. Superior grounding is the first line of defense against high-frequency noise that can destabilize sensitive analog I\/O signals.\u003c\/p\u003e\n\u003ch3\u003eVentilation and Clearances\u003c\/h3\u003e\n\u003cp\u003eAlthough the module handles heat efficiently, maintain the standard Yokogawa cabinet spacing of at least 50mm above and below the nest. Ensure the cabinet fans are operational to prevent localized heat pockets that could accelerate capacitor aging.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use the PW481-11 in a 220V AC system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis strictly rated for 100–120 V AC. For 220–240 V AC applications, you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Applying 220V to this module will cause immediate hardware failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does the module handle a momentary power dip?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes an internal hold-up time capability. It maintains a stable 24V output during brief voltage sags (typically up to 20ms), allowing the system to ride through minor utility fluctuations without rebooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the module hot-swappable in all configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Hot-swapping is supported only in redundant (Duplex) Field Control Units. In a single-power configuration, removing the module will shut down the control node. Always verify redundancy status at the HIS (Human Interface Station) before removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the significance of the -11 suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The \"11\" identifies the module as a 100V AC standard type. If your existing module has different suffix numbers, it may indicate a different voltage range or specialized coating; check your system manifest for exact compatibility.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45897978413229,"sku":"PW481-11","price":1599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/yokogawa_pw481-11_1.jpg?v=1775703914","url":"https:\/\/www.maxwellplc.com\/products\/pw481-11-yokogawa-centum-vp-power-supply-module-100-120v-ac","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}